Low-GWP refrigerants in heat pumps: An experimental investigation of the influence of an internal heat exchanger

被引:0
|
作者
Hoeges, Christoph [1 ]
Klingebiel, Jonas [1 ]
Venzik, Valerius [1 ]
Brach, Jona [1 ]
Roy, Philipp [1 ]
Neumann, Kaj [1 ]
Vering, Christian [1 ]
Mueller, Dirk [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Energy Efficient Bldg & Indoor Climate, EON Energy Res Ctr, Aachen, Germany
关键词
Rotary compressor; Brine-water heat pump; Natural refrigerants; Zeotropic mixtures; Energy efficiency; R290; DROP-IN REPLACEMENT; PERFORMANCE EVALUATION; WORKING; R1234YF; SYSTEM; MIXTURES; R134A; R600A; R450A; R404A;
D O I
10.1016/j.ecmx.2024.100704
中图分类号
O414.1 [热力学];
学科分类号
摘要
In heat pumps, the use of refrigerants with a low global warming potential (GWP) gains importance due to increasingly strict regulations regarding their ecological impact. In this regard, hydrocarbons (HCs), hydrofluoroolefins (HFOs), and their mixtures are the most promising options due to their thermodynamic properties. Besides the impact of the refrigerant, the cycle configuration (e.g., basic cycle and internal heat exchanger cycle) strongly influences the efficiency of the heat pump. While the potential of low-GWP refrigerants in internal heat exchanger (IHX) cycle configurations is widely investigated in numerical studies, there is a lack of experimental validation. Therefore, this work experimentally evaluates four HCs (R290, R600a, R436A, R1270) and the HFO R1234yf in comparison to R134a in a brine-water heat pump test bench. The test bench design allows to switch between the basic and IHX cycle, thus, enabling the simultaneous impact evaluation of the cycle configuration and the refrigerant on the performance. In the experiments, R1270 shows the highest efficiency for all operating points followed by R290 in the basic cycle. The IHX cycle improves the efficiency for all refrigerants in comparison to the basic cycle. The zeotropic mixture R436A achieves the highest efficiency improvements of up to 27.5% compared to the basic cycle, whereas the efficiency of the single-component refrigerants increases by 10% on average. Despite the significantly higher improvements of R436A due to the IHX, R1270 still leads to the highest coefficient of performance (COP) of up to 6.6 (B12/W35) in the IHX cycle configuration.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Vapor compression heat pumps with pure Low-GWP refrigerants
    Wu, Di
    Hu, Bin
    Wang, R. Z.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 138
  • [2] The influence of internal heat exchanger on energy efficiency and environmental effects of the Heat Pump using Low-GWP Refrigerants as substitutes
    Zhao Yuqing
    Dai Yun
    Gaoyan
    Xie Lanyi
    Hou Xiangyang
    Gao Jianling
    2018 INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT (GBEM 2018), 2018, 186
  • [3] OPTIMIZED AIR-TO-REFRIGERANT HEAT EXCHANGER WITH LOW-GWP REFRIGERANTS
    Cho, Honghuyun
    Domanski, Piotr A.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 861 - 868
  • [4] The life cycle climate performance evaluation of low-GWP refrigerants for domestic heat pumps
    Yang, Changru
    Seo, Sangwon
    Takata, Nobuo
    Thu, Kyaw
    Miyazaki, Takahiko
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 121 : 33 - 42
  • [5] Thermodynamic assessment of high-temperature heat pumps using Low-GWP HFO refrigerants for heat recovery
    Kondou, Chieko
    Koyama, Shigeru
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 53 : 126 - 141
  • [6] Low-GWP refrigerants
    Brown, J. Steven
    Zilio, Claudio
    Akasaka, Ryo
    Higashi, Yukihiro
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (08) : 1075 - 1076
  • [7] Analysis and selection on low-GWP refrigerants in cascade heat pump system
    Yan, Hongzhi
    Wang, Ruzhu
    Hu, Bin
    Eikevik, T. M.
    15TH IIR-GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS, 2022, : 1072 - 1080
  • [8] Performance simulation of the indoor unit of a heat pump with low-GWP alternative refrigerants
    Vasu, Amal
    Chang, Young Soo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2025, 39 (02) : 997 - 1007
  • [9] Evaporation heat transfer and pressure drop of low-gwp refrigerants in a horizontal tube
    Li, Zhaohua
    Jiang, Hanying
    Chen, Xinwen
    Liang, Kun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 148
  • [10] Selection and validation on low-GWP refrigerants for a water-source heat pump
    Yan, Hongzhi
    Wu, Di
    Liang, Junyu
    Hu, Bin
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2021, 193