Quality assurance for a treatment planning system in scanned ion beam therapy

被引:43
|
作者
Jäkel, O
Hartmann, GH
Karger, CP
Heeg, P
Rassow, J
机构
[1] Deutsch Krebsforschungszentrum, Abt E0400, D-69120 Heidelberg, Germany
[2] Univ Essen Gesamthsch, Radiol Ctr, Essen, Germany
关键词
quality assurance; treatment planning; scanned ion beam;
D O I
10.1118/1.599025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conformal radiation therapy using dynamic beam delivery systems like scanned ion beams requires concise quality assurance procedures for the complete treatment planning process. For the heavy ion therapy facility at GSI, Darmstadt, a quality assurance program for the treatment planning system (TPS) has been developed. It covers the development and updating of software, data protection and safety, and the application of soft- and hardware. The tests also apply to the geometrical precision of imaging devices and the geometrical and dosimetrical verification of dose distributions in different phantoms. The quality assurance program addresses acceptance and constancy tests of the treatment planning program. Results of the acceptance tests served as a basis for its governmental approval. Two main results of the acceptance tests are representative for the overall performance of the system. (1) The geometrical uncertainty that could be achieved for the target point definition, setup accuracy, field contouring, and field alignment is typically 1.5 mm. The uncertainty for the setup verification using digitally reconstructed radiographs (DRR's) is limited to 2 mm. (2) The mean deviations between measured and planned dose values is 3% for standardized cases in a water phantom and up to 6% for more complicated treatment configurations. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00707-0].
引用
收藏
页码:1588 / 1600
页数:13
相关论文
共 50 条
  • [41] 4D treatment planning for scanned ion beams
    Bert, Christoph
    Rietzel, Eike
    RADIATION ONCOLOGY, 2007, 2 (1)
  • [42] COMMISSIONING AND QUALITY ASSURANCE OF TREATMENT PLANNING COMPUTERS
    VANDYK, J
    BARNETT, RB
    CYGLER, JE
    SHRAGGE, PC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (02): : 261 - 273
  • [43] STRATEGIES FOR CARBON ION TREATMENT PLANNING AT THE HEIDELBERG ION-BEAM THERAPY CENTRE
    Ecker, S.
    Ackermann, B.
    Brons, S.
    Ellerbrock, M.
    Heeg, P.
    Henkner, K.
    Nairz, O.
    Winter, M.
    Jaekel, O.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S541 - S541
  • [44] Development of Accurate/Advanced Radiotherapy Treatment Planning and Quality Assurance System (ARTS)
    Wu Yi-Can
    Song Gang
    Cao Rui-Fen
    Wu Ai-Dong
    Cheng Meng-Yun
    Tang Zheng-Dao
    Li Gui
    Jing Jia
    Liu Hui
    Li Jia
    Lan Hai-Yang
    Meng Yao
    Zheng Hua-Qing
    Jin Chu-Feng
    Zeng Qin
    Zheng Shan-Liang
    Huang Qun-Ying
    Wu Li-Jun
    Li Guo-Li
    Lin Hui
    Tao Sheng-Xiang
    Shi Chang-Bei
    CHINESE PHYSICS C, 2008, 32 : 177 - 182
  • [45] Design and performance of daily quality assurance system for carbon ion therapy at NIRS
    Saotome, N.
    Furukawa, T.
    Hara, Y.
    Mizushima, K.
    Tansho, R.
    Saraya, Y.
    Shirai, T.
    Noda, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 406 : 356 - 360
  • [46] Multigating, a 4D Optimized Beam Tracking in Scanned Ion Beam Therapy
    Graeff, Christian
    Constantinescu, Anna
    Luechtenborg, Robert
    Durante, Marco
    Bert, Christoph
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (06) : 497 - 504
  • [47] Treatment planning for a scanned carbon beam with a modified microdosimetric kinetic model
    Inaniwa, Taku
    Furukawa, Takuji
    Kase, Yuki
    Matsufuji, Naruhiro
    Toshito, Toshiyuki
    Matsumoto, Yoshitaka
    Furusawa, Yoshiya
    Noda, Koji
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22): : 6721 - 6737
  • [48] Trend lines on patient specific quality assurance in ion beam therapy with protons and carbon ions
    Schafasand, M.
    Kragl, G.
    Osorio, J.
    Vatnitsky, S.
    Stock, M.
    Carlino, A.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S748 - S748
  • [49] A 4D-optimization concept for scanned ion beam therapy
    Graeff, Christian
    Luechtenborg, Robert
    Eley, John Gordon
    Durante, Marco
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 419 - 424
  • [50] Stereotactic Body Radiation Therapy for Peripheral Lung Lesion: Treatment Planning and Quality Assurance
    Wan, Shuying
    Oliver, Michael
    Wang, Xiaofang
    MEDICAL PHYSICS, 2014, 41 (08) : 13 - 13