Quality assurance for a treatment planning system in scanned ion beam therapy

被引:43
|
作者
Jäkel, O
Hartmann, GH
Karger, CP
Heeg, P
Rassow, J
机构
[1] Deutsch Krebsforschungszentrum, Abt E0400, D-69120 Heidelberg, Germany
[2] Univ Essen Gesamthsch, Radiol Ctr, Essen, Germany
关键词
quality assurance; treatment planning; scanned ion beam;
D O I
10.1118/1.599025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conformal radiation therapy using dynamic beam delivery systems like scanned ion beams requires concise quality assurance procedures for the complete treatment planning process. For the heavy ion therapy facility at GSI, Darmstadt, a quality assurance program for the treatment planning system (TPS) has been developed. It covers the development and updating of software, data protection and safety, and the application of soft- and hardware. The tests also apply to the geometrical precision of imaging devices and the geometrical and dosimetrical verification of dose distributions in different phantoms. The quality assurance program addresses acceptance and constancy tests of the treatment planning program. Results of the acceptance tests served as a basis for its governmental approval. Two main results of the acceptance tests are representative for the overall performance of the system. (1) The geometrical uncertainty that could be achieved for the target point definition, setup accuracy, field contouring, and field alignment is typically 1.5 mm. The uncertainty for the setup verification using digitally reconstructed radiographs (DRR's) is limited to 2 mm. (2) The mean deviations between measured and planned dose values is 3% for standardized cases in a water phantom and up to 6% for more complicated treatment configurations. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00707-0].
引用
收藏
页码:1588 / 1600
页数:13
相关论文
共 50 条
  • [31] Experimental validation of a beam tracking system for the treatment of moving targets with scanned ion beams
    Schmidt, A.
    Bert, C.
    Saito, N.
    Iancu, G.
    von Neubeck, C.
    Chaudhri, N.
    Schardt, D.
    Rietzel, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S27 - S27
  • [32] Speed and accuracy of a beam tracking system for treatment of moving targets with scanned ion beams
    Saito, Nami
    Bert, Christoph
    Chaudhri, Naved
    Gemmel, Alexander
    Schardt, Dieter
    Durante, Marco
    Rietzel, Eike
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (16): : 4849 - 4862
  • [33] QUALITY ASSURANCE OF COMPUTERIZED THERAPY PLANNING SYSTEMS
    BRAHMAVAR, SM
    LAFRANCE, M
    PARK, WC
    MEDICAL PHYSICS, 1982, 9 (04) : 638 - 639
  • [34] Fast optimization and dose calculation in scanned ion beam therapy
    Hild, S.
    Graeff, C.
    Trautmann, J.
    Kraemer, M.
    Zink, K.
    Durante, M.
    Bert, C.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [35] A trichrome beam model for biological dose calculation in scanned carbon-ion radiotherapy treatment planning
    Inaniwa, T.
    Kanematsu, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01): : 437 - 451
  • [36] QUALITY ASSURANCE FOR ELECTRON-BEAM THERAPY
    WILLIAMS, PC
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (707): : 1141 - 1141
  • [37] Investigations of a flat-panel detector for quality assurance measurements in ion beam therapy
    Hartmann, Bernadette
    Telsemeyer, Julia
    Huber, Lucas
    Ackermann, Benjamin
    Jaekel, Oliver
    Martisikova, Maria
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 51 - 68
  • [38] Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System
    Ding, K.
    Ji, T.
    Iordachita, I.
    Velarde, E.
    Hyatt, J.
    Wong, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3515 - 3515
  • [39] 4D treatment planning for scanned ion beams
    Christoph Bert
    Eike Rietzel
    Radiation Oncology, 2
  • [40] Advances in 4D Treatment Planning for Scanned Particle Beam Therapy - Report of Dedicated Workshops
    Bert, Christoph
    Graeff, Christian
    Riboldi, Marco
    Nill, Simeon
    Baroni, Guido
    Knopf, Antje-Christin
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (06) : 485 - 495