摘要
Conformal radiation therapy using dynamic beam delivery systems like scanned ion beams requires concise quality assurance procedures for the complete treatment planning process. For the heavy ion therapy facility at GSI, Darmstadt, a quality assurance program for the treatment planning system (TPS) has been developed. It covers the development and updating of software, data protection and safety, and the application of soft- and hardware. The tests also apply to the geometrical precision of imaging devices and the geometrical and dosimetrical verification of dose distributions in different phantoms. The quality assurance program addresses acceptance and constancy tests of the treatment planning program. Results of the acceptance tests served as a basis for its governmental approval. Two main results of the acceptance tests are representative for the overall performance of the system. (1) The geometrical uncertainty that could be achieved for the target point definition, setup accuracy, field contouring, and field alignment is typically 1.5 mm. The uncertainty for the setup verification using digitally reconstructed radiographs (DRR's) is limited to 2 mm. (2) The mean deviations between measured and planned dose values is 3% for standardized cases in a water phantom and up to 6% for more complicated treatment configurations. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00707-0].
引用
收藏
页码:1588 / 1600
页数:13
相关论文
共 50 条
  • [1] Patient Treatment Quality Assurance for a Uniformly Scanned Proton Therapy Beam
    Baillie, N.
    Lee, T.
    Duvvuri, S.
    Shahnazi, K.
    Athar, B.
    Long, C.
    Butuceanu, C.
    Nazaryan, V.
    Keppel, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3538 - 3539
  • [2] TREATMENT PLANNING FOR SCANNED ION BEAM THERAPY IN CLINICAL ROUTINE
    Ellerbrock, M.
    Ackermann, B.
    Brons, S.
    Heeg, P.
    Henkner, K.
    Ecker, S.
    Nairz, O.
    Winter, M.
    Mairani, A.
    Parodi, K.
    Jaekel, O.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S542 - S543
  • [3] Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy
    Richter, D.
    Schwarzkopf, A.
    Trautmann, J.
    Kraemer, M.
    Durante, M.
    Jaekel, O.
    Bert, C.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [4] Assessment of Uncertainties in Treatment Planning for Scanned Ion Beam Therapy of Moving Tumors
    Hild, Sebastian
    Durante, Marco
    Bert, Christoph
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 528 - 535
  • [5] An institutional experience of quality assurance of a treatment planning system on photon beam
    Ozguven, Yildiray
    Yaray, Kadir
    Alkaya, Fadime
    Yucel, Birsen
    Soyuer, Serdar
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (03) : 195 - 205
  • [6] An institutional experience: quality assurance of a treatment planning system on electron beam
    Yaray, Kadir
    Ozguven, Yildiray
    Alkaya, Fadime
    Yucel, Birsen
    Soyuer, Serdar
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2013, 28 (04): : 154 - 162
  • [7] Feature-based plan adaptation for fast treatment planning in scanned ion beam therapy
    Chen, Wenjing
    Gemmel, Alexander
    Rietzel, Eike
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04): : 1013 - 1025
  • [8] Patient-Specific Quality Assurance of Dynamically Collimated Pencil Beam Scanned Proton Therapy Treatment Plans
    Bennett, L.
    Hyer, D. E.
    Vu, N.
    Patwardhan, K. A.
    Erhart, K. J.
    Gutierrez, A. N.
    Pons, E.
    Jensen, E.
    Ubau, M.
    Zapata, J.
    Wroe, A. J.
    Wake, K. K.
    Nelson, N. P.
    Culberson, W. S.
    Smith, R.
    Hill, P. M.
    Flynn, R. T.
    MEDICAL PHYSICS, 2024, 51 (10) : 7798 - 7798
  • [9] Treatment Planning for Ion Beam Therapy
    Greilich, Steffen
    Jaekel, Oliver
    NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2009, 1204 : 111 - 115
  • [10] Treatment planning for scanned ion beams
    Krämer, M
    Jäkel, O
    Haberer, T
    Rietzel, E
    Schardt, D
    Scholz, M
    Wang, JF
    Weber, U
    Weyrather, W
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S80 - S85