RF shielding materials for highly-integrated PET/MRI systems

被引:7
|
作者
Yin, Laiyin [1 ]
Schrank, Franziska [1 ]
Gross-Weege, Nicolas [1 ]
Schug, David [1 ,2 ]
Schulz, Volkmar [1 ,2 ,3 ,4 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, Aachen, Germany
[2] Hyper Hybrid Imaging Syst GmbH, Aachen, Germany
[3] Rhein Westfal TH Aachen, Phys Inst 3 B, Aachen, Germany
[4] Fraunhofer Inst Digital Med MEVIS, Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 09期
关键词
PET; MRI; RF shielding; RF shielding material; integrated PET; integrated RF shielding; preclinical PET;
D O I
10.1088/1361-6560/abf606
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) into a simultaneous device calls for adaptations of the radio frequency (RF) shielding concept. Conventional PET module housings fully encase the entire PET detector to reduce mutual interference. Excluding passive components, i.e. scintillators, from the housings, offers integration advantages, e.g. by reducing the overall housing volume or utilizing bigger scintillators. However, locating the scintillator outside of the RF shielding requires an optically transparent RF shielding interface between the scintillators and the photodetector to close the aperture. Therefore, a careful evaluation and selection of RF materials is essential to ensure an excellent PET/MRI system performance. To this end, we examined 10 materials (coated glasses, coated foils, meshes). The shielding effectiveness (SE) was evaluated at 100 and 300 MHz. PET performance was tested for single event registration and coincident events by integrating the material into the PET detector stack between the digital silicon photomultiplier photodetector array and one-to-one coupled scintillator. We determined photon attenuation (PA), energy resolution (dE/E), and coincidence resolving time (CRT) and compared to reference measurements for each material group. MRI compatibility was assessed by analyzing the material influence on the main magnetic field (B-0) homogeneity. The coated glasses and foils exhibited SEs of up to 25 dB at 300 MHz. Both had a PA < 23% with dE/E and CRT comparable to the reference measurements, and no measurable impact on the B-0 field was registered. The meshes exhibited higher SEs up to 56 dB, but also a PA > 58% with a higher impact on dE/E and CRT. Only one mesh affected B-0 homogeneity. Overall, we recommend the coated foil HS 9400 for integration concepts as it exhibited a good performance with SE = 25 dB, PA = 22%, resulting in a PET performance of dE/E = 12% and CRT = 274 ps.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Design-for-reliability tools for highly-integrated system-on-package technology
    Pucha, R. V.
    Hegde, S.
    Damani, M.
    Leee, K. J.
    Tunga, K.
    Perkins, A.
    Mahalingam, S.
    Lo, G.
    Klein, K.
    Ahmad, J.
    Sitaraman, S. K.
    EUROSIME 2007: THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICRO-ELECTRONICS AND MICRO-SYSTEMS, PROCEEDINGS, 2007, : 692 - 692
  • [42] A Smart Energy Management System of a Highly-Integrated Battery-Ultracapacitor System
    Salimbeni, Andrea
    Porru, Mario
    Damiano, Alfonso
    Serpi, Alessandro
    2020 2ND IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL ELECTRONICS FOR SUSTAINABLE ENERGY SYSTEMS (IESES), 2020, : 27 - 32
  • [43] RF integrated systems
    Belot, D
    MICROELECTRONIC ENGINEERING, 2000, 54 (1-2) : 103 - 111
  • [44] The first clinical test of Add-on PET: A PET-integrated RF coil for 3T MRI
    Takahashi, Miwako
    Nishikido, Fumihiko
    Akamatsu, Go
    Tashima, Hideaki
    Suga, Mikio
    Iwao, Yuma
    Yamaya, Taiga
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [45] Highly-Integrated Signal and Pump Combiner in Chirally-Coupled-Core Fibers
    Hochheim, Sven
    Brockmueller, Eike
    Wessels, Peter
    Steinke, Michael
    Koponen, Joona
    Lowder, Tyson
    Novotny, Steffen
    Neumann, Joerg
    Kracht, Dietmar
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (22) : 7246 - 7250
  • [46] Considerations on Design of Highly-Integrated Millimeter-Wave Transceivers in SiGe HBT
    Issakov, V.
    Trotta, S.
    2018 IEEE INTERNATIONAL ELECTRON DEVICES MEETING (IEDM), 2018,
  • [47] Prototype integrated system of DOI-PET and the RF-coil specialized for simultaneous PET-MRI measurements
    Nishikido, Fumihiko
    Obata, Takayuki
    Inadama, Naoko
    Yoshida, Eiji
    Tashima, Hideaki
    Suga, Mikio
    Murayama, Hideo
    Ito, Hiroshi
    Yamaya, Taiga
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2750 - 2752
  • [48] In-Antenna Power Combining for Highly-Integrated Millimeter-Wave Transmitters
    Goettel, Benjamin
    Bhutani, Akanksha
    Marahrens, Soeren
    Zwick, Thomas
    2020 14TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP 2020), 2020,
  • [49] A novel highly-integrated light guide plate using micro optical technique
    Xu, Ping
    Chen, Xiangxan
    Huang, Jiefeng
    Zhang, Xulin
    Wan, Lili
    Wang, Kai
    Liu, Jiayong
    OPTICAL DESIGN AND TESTING III, PTS 1 AND 2, 2008, 6834
  • [50] SYSTEM DESIGN CONSIDERATIONS OF HIGHLY-INTEGRATED ΣΔ FRACTIONAL-N FREQUENCY SYNTHESIZER
    Huang, Shuilong
    Wang, Zhihua
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2008, 17 (02) : 169 - 181