RF shielding materials for highly-integrated PET/MRI systems

被引:7
|
作者
Yin, Laiyin [1 ]
Schrank, Franziska [1 ]
Gross-Weege, Nicolas [1 ]
Schug, David [1 ,2 ]
Schulz, Volkmar [1 ,2 ,3 ,4 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, Aachen, Germany
[2] Hyper Hybrid Imaging Syst GmbH, Aachen, Germany
[3] Rhein Westfal TH Aachen, Phys Inst 3 B, Aachen, Germany
[4] Fraunhofer Inst Digital Med MEVIS, Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 09期
关键词
PET; MRI; RF shielding; RF shielding material; integrated PET; integrated RF shielding; preclinical PET;
D O I
10.1088/1361-6560/abf606
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) into a simultaneous device calls for adaptations of the radio frequency (RF) shielding concept. Conventional PET module housings fully encase the entire PET detector to reduce mutual interference. Excluding passive components, i.e. scintillators, from the housings, offers integration advantages, e.g. by reducing the overall housing volume or utilizing bigger scintillators. However, locating the scintillator outside of the RF shielding requires an optically transparent RF shielding interface between the scintillators and the photodetector to close the aperture. Therefore, a careful evaluation and selection of RF materials is essential to ensure an excellent PET/MRI system performance. To this end, we examined 10 materials (coated glasses, coated foils, meshes). The shielding effectiveness (SE) was evaluated at 100 and 300 MHz. PET performance was tested for single event registration and coincident events by integrating the material into the PET detector stack between the digital silicon photomultiplier photodetector array and one-to-one coupled scintillator. We determined photon attenuation (PA), energy resolution (dE/E), and coincidence resolving time (CRT) and compared to reference measurements for each material group. MRI compatibility was assessed by analyzing the material influence on the main magnetic field (B-0) homogeneity. The coated glasses and foils exhibited SEs of up to 25 dB at 300 MHz. Both had a PA < 23% with dE/E and CRT comparable to the reference measurements, and no measurable impact on the B-0 field was registered. The meshes exhibited higher SEs up to 56 dB, but also a PA > 58% with a higher impact on dE/E and CRT. Only one mesh affected B-0 homogeneity. Overall, we recommend the coated foil HS 9400 for integration concepts as it exhibited a good performance with SE = 25 dB, PA = 22%, resulting in a PET performance of dE/E = 12% and CRT = 274 ps.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Sustainability Metrics for Highly-Integrated Biofuel Production Facilities
    Spriggs, H. Dennis
    Brant, Benjamin
    Rudnick, Daniel
    Hall, Kenneth R.
    El-Halwagi, Mahmoud M.
    DESIGN FOR ENERGY AND THE ENVIRONMENT, 2010, : 399 - 404
  • [22] Performance limitation improvement for a highly-integrated chemical process
    Cao, Y
    Rossiter, D
    Owens, D
    COMPUTERS & CHEMICAL ENGINEERING, 1999, 23 : S245 - S248
  • [23] Development of the shielding materials having the highly orientation characteristics in the RF magnetic field
    Nishikub T.
    Itoh M.
    IEEJ Transactions on Electronics, Information and Systems, 2010, 130 (12) : 2227 - 2236+18
  • [24] THE MRI SHIELDING PERFORMANCE OF A CYLINDRICAL IRON MAGNETIC-SHIELD WITH AN INTEGRATED RF SHIELD
    FLYNN, MJ
    WINDHAM, JP
    EWING, JR
    HEARSHEN, D
    FROELICH, J
    ISSA, C
    BLOCK, R
    MEDICAL PHYSICS, 1985, 12 (04) : 510 - 510
  • [25] Highly-integrated planar lightwave circuit wavelength selective switch
    Earnshaw, MP
    Cappuzzo, M
    Chen, E
    Gomez, L
    Griffin, A
    Laskowski, E
    Wong-Foy, A
    ELECTRONICS LETTERS, 2003, 39 (19) : 1397 - 1398
  • [26] Interoperable Blockchains for Highly-Integrated Supply Chains in Collaborative Manufacturing
    Bellavista, Paolo
    Esposito, Christian
    Foschini, Luca
    Giannelli, Carlo
    Mazzocca, Nicola
    Montanari, Rebecca
    SENSORS, 2021, 21 (15)
  • [27] A highly-integrated fractional-N synthesizer for FMCW radar
    Eickhoff, Ralf
    Ellinger, Frank
    Ussmueller, Thomas
    Spiegel, Solon
    2008 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, COMMUNICATIONS, ANTENNAS AND ELECTRONIC SYSTEMS, 2008, : 84 - +
  • [28] Fabrication of highly-integrated thermoelectric generators based on Ionic Liquids
    Uhl, Stefanie
    Pellet, Michael
    Tschanz, Jessica
    Laux, Edith
    Journot, Tony
    Jeandupeux, Laure
    Keppner, Herbert
    MATERIALS TODAY-PROCEEDINGS, 2015, 2 (02) : 669 - 674
  • [29] A Highly-Integrated CMOS Transceiver for Active Structural Health Monitoring
    Tang, Xinyao
    Zhao, Haixiang
    Mandal, Soumyajit
    PROCEEDINGS OF THE 2016 IEEE NATIONAL AEROSPACE AND ELECTRONICS CONFERENCE (NAECON) AND OHIO INNOVATION SUMMIT (OIS), 2016, : 133 - 138
  • [30] Toward of a Highly-integrated Probe for improving wireless Network Quality
    Ding Fei
    Song Aiguo
    Wu Zhenyang
    Pan Zhiwen
    You Xiaohu
    OPTICAL COMMUNICATION AND OPTICAL FIBER SENSORS AND OPTICAL MEMORIES FOR BIG DATA STORAGE, 2016, 10158