RF shielding materials for highly-integrated PET/MRI systems

被引:7
|
作者
Yin, Laiyin [1 ]
Schrank, Franziska [1 ]
Gross-Weege, Nicolas [1 ]
Schug, David [1 ,2 ]
Schulz, Volkmar [1 ,2 ,3 ,4 ]
机构
[1] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, Aachen, Germany
[2] Hyper Hybrid Imaging Syst GmbH, Aachen, Germany
[3] Rhein Westfal TH Aachen, Phys Inst 3 B, Aachen, Germany
[4] Fraunhofer Inst Digital Med MEVIS, Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 09期
关键词
PET; MRI; RF shielding; RF shielding material; integrated PET; integrated RF shielding; preclinical PET;
D O I
10.1088/1361-6560/abf606
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) into a simultaneous device calls for adaptations of the radio frequency (RF) shielding concept. Conventional PET module housings fully encase the entire PET detector to reduce mutual interference. Excluding passive components, i.e. scintillators, from the housings, offers integration advantages, e.g. by reducing the overall housing volume or utilizing bigger scintillators. However, locating the scintillator outside of the RF shielding requires an optically transparent RF shielding interface between the scintillators and the photodetector to close the aperture. Therefore, a careful evaluation and selection of RF materials is essential to ensure an excellent PET/MRI system performance. To this end, we examined 10 materials (coated glasses, coated foils, meshes). The shielding effectiveness (SE) was evaluated at 100 and 300 MHz. PET performance was tested for single event registration and coincident events by integrating the material into the PET detector stack between the digital silicon photomultiplier photodetector array and one-to-one coupled scintillator. We determined photon attenuation (PA), energy resolution (dE/E), and coincidence resolving time (CRT) and compared to reference measurements for each material group. MRI compatibility was assessed by analyzing the material influence on the main magnetic field (B-0) homogeneity. The coated glasses and foils exhibited SEs of up to 25 dB at 300 MHz. Both had a PA < 23% with dE/E and CRT comparable to the reference measurements, and no measurable impact on the B-0 field was registered. The meshes exhibited higher SEs up to 56 dB, but also a PA > 58% with a higher impact on dE/E and CRT. Only one mesh affected B-0 homogeneity. Overall, we recommend the coated foil HS 9400 for integration concepts as it exhibited a good performance with SE = 25 dB, PA = 22%, resulting in a PET performance of dE/E = 12% and CRT = 274 ps.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Assessment of Shielding Materials for the Add-on PET at Different Magnetic Field Strengths of MRI
    Fujiwara, Masanori
    Suga, Mikio
    Nishikido, Fumihiko
    Nitta, Munetaka
    Kawabata, Yoshihiko
    Yamaya, Taiga
    Obata, Takayuki
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [32] Developing Highly-Integrated Subcutaneous Biochips for Remote Monitoring of Human Metabolism
    Carrara, Sandro
    Cavallini, Andrea
    Ghoreishizadeh, Sara
    Olivo, Jacopo
    De Micheli, Giovanni
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 271 - 274
  • [33] Highly-Integrated Guidewire Vascular Ultrasound Imaging System-on-a-Chip
    Lim, Jaemyung
    Tekes, Coskun
    Rezvanitabar, Ahmad
    Arkan, Evren F.
    Degertekin, F. Levent
    Ghovanloo, Maysam
    2018 IEEE CUSTOM INTEGRATED CIRCUITS CONFERENCE (CICC), 2018,
  • [34] The first human study of add-on PET: A PET-integrated RF coil for 3 T MRI
    Takahashi, Miwako
    Nishikido, Fumihiko
    Akamatsu, Go
    Tashima, Hideaki
    Iwao, Yuma
    Suga, Mikio
    Yamaya, Taiga
    EJNMMI PHYSICS, 2025, 12 (01):
  • [35] A highly-integrated and efficient commercial distributed EV battery balancing system
    Chen, Feng
    Yuan, Jun
    Zheng, Chaojun
    Wang, Canbo
    Li, Zhan
    IEICE ELECTRONICS EXPRESS, 2018, 15 (08):
  • [36] A highly-integrated inductor-less SiGeW-CDMA transmitter
    Shih, HY
    Su, PU
    Chen, YH
    Fu, TH
    Liu, JL
    Juang, KC
    Kuo, MC
    Hsu, CM
    2004 IEEE RADIO FREQUENCY INTEGRATED CIRCUITS (RFIC) SYMPOSIUM, DIGEST OF PAPERS, 2004, : 439 - 442
  • [37] Optimized RF shielding techniques for simultaneous PET/MR
    Truhn, D.
    Kiessling, F.
    Schulz, V.
    MEDICAL PHYSICS, 2011, 38 (07) : 3995 - 4000
  • [38] Design and analysis of a highly-integrated CMOS power amplifier for RFID readers
    高同强
    张春
    池保勇
    王志华
    半导体学报, 2009, 30 (06) : 121 - 125
  • [39] Design and analysis of a highly-integrated CMOS power amplifier for RFID readers
    Gao Tongqiang
    Zhang Chun
    Chi Baoyong
    Wang Zhihua
    JOURNAL OF SEMICONDUCTORS, 2009, 30 (06)
  • [40] Integrated PET and MRI Scanners
    Carpenter, T. Adrian
    Ansorge, Richard