A NOVEL NONINVASIVE IMPEDANCE-BASED TECHNIQUE FOR CENTRAL VENOUS PRESSURE MEASUREMENT

被引:6
|
作者
Ward, Kevin R. [1 ,2 ,3 ]
Tiba, Mohamad H. [1 ,2 ]
Draucker, Gerard T. [1 ,2 ]
Proffitt, Elizabeth K. [1 ,2 ,4 ]
Barbee, Robert W. [1 ,2 ,3 ]
Gunnerson, Kyle J. [1 ,2 ,5 ]
Reynolds, Penny S. [1 ,2 ]
Spiess, Bruce D. [1 ,2 ,5 ]
机构
[1] Virginia Commonwealth Univ Reanimat Engn Shock Ct, Richmond, VA USA
[2] Virginia Commonwealth Univ, Dept Emergency Med, Richmond, VA USA
[3] Virginia Commonwealth Univ, Dept Physiol, Richmond, VA USA
[4] Virginia Commonwealth Univ, Dept Biomed Engn, Richmond, VA USA
[5] Virginia Commonwealth Univ, Dept Anesthesiol, Richmond, VA USA
来源
SHOCK | 2010年 / 33卷 / 03期
关键词
Monitoring; catheter; critical illness; injury; volume assessment; CRITICALLY-ILL PATIENTS; ADVANCED HEART-FAILURE; HEMODYNAMIC ASSESSMENT; SEVERE SEPSIS; SEPTIC SHOCK; AGREEMENT; CATHETERIZATION; ULTRASOUND;
D O I
10.1097/SHK.0b013e3181ab9b9b
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Knowledge of central venous pressure (CVP) is considered valuable in the assessment and treatment of various states of critical illness and injury. We tested a noninvasive means of determining CVP (NICVP) by monitoring upper arm blood flow changes in response to externally applied circumferential pressure to the upper arm veins. Thirty-six patients who were undergoing CVP monitoring as part of their care had NICVP determined and compared with CVP. Volume changes were measured in the upper arm using tetra-polar impedance plethysmography underneath a blood pressure cuff. The cuff was inflated over 5 s to a pressure greater than CVP but less than diastolic arterial pressure. After 45 to 60 s, the cuff was rapidly deflated. Noninvasive CVP was determined as the cuff pressure noted at the maximum derivative of the volume increase under the cuff during deflation. Noninvasive CVP was then compared with invasively measured CVP taken during the same period by Bland-Altman analysis. A total of 108 trials (three per subject) were performed on 36 patients. Mean bias was -0.26 mmHg (95% confidence interval [CI]: -0.67, 0.15). Limits of agreement were -2.7 and 2.2 mmHg with the 95% CI for the lower limit of agreement (-3.4, -2.0 mmHg) and for the upper limit of agreement (1.5, 2.9 mmHg). Correlation between CVP and NICVP was 0.95 (95% CI: 0.93 to 0.97; P < 0.0001). Noninvasive CVP as determined in this study may be a clinically useful substitute for traditional CVP measurement and may offer a tool for early diagnosis and treatment of acute states in which knowledge of CVP would be helpful.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [31] AID TO MEASUREMENT OF CENTRAL VENOUS PRESSURE
    SCOTT, PV
    BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (11) : 1025 - &
  • [32] CENTRAL-VENOUS-PRESSURE MEASUREMENT
    BENZIE, RJ
    SMITH, I
    LANCET, 1971, 1 (7711): : 1241 - &
  • [33] NONINVASIVE VENOUS-PRESSURE MEASUREMENT AND ITS VALIDATION
    BARTOLO, M
    ANTIGNANI, PL
    NICOSIA, PM
    TODINI, AR
    INTERNATIONAL ANGIOLOGY, 1988, 7 (02) : 182 - 189
  • [34] Error in Central Venous Pressure Measurement
    Figg, Katie K.
    Nemergut, Edward C.
    ANESTHESIA AND ANALGESIA, 2009, 108 (04): : 1209 - 1211
  • [35] MEASUREMENT OF CENTRAL VENOUS-PRESSURE
    AMOROSO, P
    BRITISH MEDICAL JOURNAL, 1991, 303 (6808): : 994 - 994
  • [36] CENTRAL VENOUS-PRESSURE MEASUREMENT
    SINAPIUS, D
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1973, 98 (28) : 1383 - 1383
  • [37] Validity of noninvasive central aortic pressure measurement
    O'Rourke, Michael F.
    Takazawa, Kenji
    Tanaka, Nobuhiro
    JOURNAL OF HYPERTENSION, 2019, 37 (11) : 2300 - 2301
  • [38] NONINVASIVE DETERMINATION OF CENTRAL BLOOD-PRESSURE BY IMPEDANCE PLETHYSMOGRAPHY
    HERSCOVICI, H
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (06) : 617 - 625
  • [39] Comparison between noninvasive measurement of central venous pressure using near infrared spectroscopy with an invasive central venous pressure monitoring in cardiac surgical Intensive Care Unit
    Sathish, N.
    Singh, Naveen G.
    Nagaraja, P. S.
    Sarala, B. M.
    Prabhushankar, C. G.
    Dhananjaya, Manasa
    Manjunatha, N.
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (03) : 405 - 409
  • [40] New Method for Noninvasive Quantification of Central Venous Pressure by Ultrasound
    Xing, Chang-Yang
    Liu, Yuan-Ling
    Zhao, Mei-Ling
    Yang, Rui-Jing
    Duan, Yun-You
    Zhang, Lian-Hua
    Sun, Xu-De
    Yuan, Li-Jun
    Cao, Tie-Sheng
    CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (05)