A NOVEL NONINVASIVE IMPEDANCE-BASED TECHNIQUE FOR CENTRAL VENOUS PRESSURE MEASUREMENT

被引:6
|
作者
Ward, Kevin R. [1 ,2 ,3 ]
Tiba, Mohamad H. [1 ,2 ]
Draucker, Gerard T. [1 ,2 ]
Proffitt, Elizabeth K. [1 ,2 ,4 ]
Barbee, Robert W. [1 ,2 ,3 ]
Gunnerson, Kyle J. [1 ,2 ,5 ]
Reynolds, Penny S. [1 ,2 ]
Spiess, Bruce D. [1 ,2 ,5 ]
机构
[1] Virginia Commonwealth Univ Reanimat Engn Shock Ct, Richmond, VA USA
[2] Virginia Commonwealth Univ, Dept Emergency Med, Richmond, VA USA
[3] Virginia Commonwealth Univ, Dept Physiol, Richmond, VA USA
[4] Virginia Commonwealth Univ, Dept Biomed Engn, Richmond, VA USA
[5] Virginia Commonwealth Univ, Dept Anesthesiol, Richmond, VA USA
来源
SHOCK | 2010年 / 33卷 / 03期
关键词
Monitoring; catheter; critical illness; injury; volume assessment; CRITICALLY-ILL PATIENTS; ADVANCED HEART-FAILURE; HEMODYNAMIC ASSESSMENT; SEVERE SEPSIS; SEPTIC SHOCK; AGREEMENT; CATHETERIZATION; ULTRASOUND;
D O I
10.1097/SHK.0b013e3181ab9b9b
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Knowledge of central venous pressure (CVP) is considered valuable in the assessment and treatment of various states of critical illness and injury. We tested a noninvasive means of determining CVP (NICVP) by monitoring upper arm blood flow changes in response to externally applied circumferential pressure to the upper arm veins. Thirty-six patients who were undergoing CVP monitoring as part of their care had NICVP determined and compared with CVP. Volume changes were measured in the upper arm using tetra-polar impedance plethysmography underneath a blood pressure cuff. The cuff was inflated over 5 s to a pressure greater than CVP but less than diastolic arterial pressure. After 45 to 60 s, the cuff was rapidly deflated. Noninvasive CVP was determined as the cuff pressure noted at the maximum derivative of the volume increase under the cuff during deflation. Noninvasive CVP was then compared with invasively measured CVP taken during the same period by Bland-Altman analysis. A total of 108 trials (three per subject) were performed on 36 patients. Mean bias was -0.26 mmHg (95% confidence interval [CI]: -0.67, 0.15). Limits of agreement were -2.7 and 2.2 mmHg with the 95% CI for the lower limit of agreement (-3.4, -2.0 mmHg) and for the upper limit of agreement (1.5, 2.9 mmHg). Correlation between CVP and NICVP was 0.95 (95% CI: 0.93 to 0.97; P < 0.0001). Noninvasive CVP as determined in this study may be a clinically useful substitute for traditional CVP measurement and may offer a tool for early diagnosis and treatment of acute states in which knowledge of CVP would be helpful.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [21] Impedance-based health monitoring technique for civil structures
    Park, G
    Cudney, HH
    Inman, DJ
    STRUCTURAL HEALTH MONTORING 2000, 1999, : 523 - 532
  • [22] A Noninvasive Measurement Technique of Grid and Converter Wideband Impedance
    Khatua, Riddhi
    Haldar, Arundhuti
    Malkhandi, Arpan
    Senroy, Nilanjan
    Mishra, Sukumar
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (01) : 886 - 898
  • [23] A Cuffless Blood Pressure Measurement Based on the Impedance Plethysmography Technique
    Liu, Shing-Hong
    Cheng, Da-Chuan
    Su, Chun-Hung
    SENSORS, 2017, 17 (05)
  • [24] NONINVASIVE ESTIMATION OF CENTRAL VENOUS PRESSURE IN ANESTHETIZED DOGS BY MEASUREMENT OF HEPATIC VENOUS BLOOD FLOW VELOCITY AND ABDOMINAL VENOUS DIAMETER
    Nelson, Nathan C.
    Drost, Wm Tod
    Lerche, Phillip
    Bonagura, John D.
    VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (03) : 313 - 323
  • [25] A new noninvasive method to determine central venous pressure
    Ward, Kevin R.
    Tiba, M. Hakam
    Barbee, R. Wayne
    Ivatury, Rao R.
    Arrowood, James A.
    Spiess, Bruce D.
    Hummel, Russell
    RESUSCITATION, 2006, 70 (02) : 238 - 246
  • [26] A NOVEL CONTINUOUS AND NONINVASIVE MEASUREMENT FOR BLOOD PRESSURE BASED ON PHOTOPLETHYSMOGRAPHY
    Li, Xiru
    Li, Xiaofeng
    Xu, Jinlin
    Tan, Haibo
    Yuan, Munan
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [27] NOVEL NONINVASIVE MEASUREMENT OF HEPATIC VENOUS PRESSURE GRADIENT AND PORTAL PRESSURE FROM ANATOMIC CT ANGIOGRAPHY
    Qi, X.
    Zhou, F.
    Lv, H.
    Chen, H.
    Xu, W.
    Xing, S.
    Yang, D.
    Li, G.
    Yang, C.
    JOURNAL OF HEPATOLOGY, 2013, 58 : S99 - S100
  • [28] A novel noninvasive measurement technique for analyzing the pressure pulse waveform of the radial artery
    Tyan, Chu-Chang
    Liu, Shing-Hong
    Chen, Jan-Yow
    Chen, Jian-Jung
    Liang, Wen-Miin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) : 288 - 297
  • [29] A METHOD FOR CENTRAL VENOUS PRESSURE MEASUREMENT
    MARGOLESE, R
    SURGERY, 1966, 60 (06) : 1285 - +
  • [30] MEASUREMENT OF CENTRAL VENOUS-PRESSURE
    WILMSHURST, P