Error in Central Venous Pressure Measurement

被引:50
|
作者
Figg, Katie K. [1 ]
Nemergut, Edward C. [2 ]
机构
[1] Univ Virginia, Hlth Sci Ctr, Dept Anesthesiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Hlth Sci Ctr, Dept Neurosurg, Charlottesville, VA 22908 USA
来源
ANESTHESIA AND ANALGESIA | 2009年 / 108卷 / 04期
关键词
ASPIRATION; POSITION;
D O I
10.1213/ane.0b013e318196482c
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: The variability introduced by inconsistent placement of pressure transducers for invasive monitoring may result in significant measurement error. Our goals in this study were to quantify the degree of variation among health care providers and to identify a simple tool for reducing this error. METHODS: A sample of 50 perioperative health care providers was recruited and asked to place a transducer at the appropriate level for central venous pressure (CVP) monitoring on two separate occasions: first without any additional standardization tools and second with a laser level to guide transducer placement. The variability among providers was calculated, and the results between sessions compared. RESULTS: There was significant variation in transducer placement during both sessions, in some instances, of greater magnitude than a normal CVP value. The laser level did not significantly reduce this variation. CONCLUSION: There is significant variation in transducer placement among health care providers. This variation is not reduced by a laser level and must be considered when interpreting CVP data. Hospital- or institution-wide standardization of a zero-level should be considered.
引用
收藏
页码:1209 / 1211
页数:3
相关论文
共 50 条
  • [1] MEASUREMENT OF CENTRAL VENOUS PRESSURE
    STEWART, KS
    LANCET, 1971, 1 (7702): : 756 - &
  • [2] MEASUREMENT OF CENTRAL VENOUS PRESSURE
    HOBBS, JT
    LANCET, 1966, 2 (7467): : 801 - &
  • [3] MEASUREMENT OF CENTRAL VENOUS PRESSURE
    MARSHALL, RD
    MILLER, R
    LANCET, 1969, 2 (7615): : 322 - &
  • [4] A METHOD FOR CENTRAL VENOUS PRESSURE MEASUREMENT
    MARGOLESE, R
    SURGERY, 1966, 60 (06) : 1285 - +
  • [5] MEASUREMENT OF CENTRAL VENOUS-PRESSURE
    WILMSHURST, P
    BRITISH MEDICAL JOURNAL, 1991, 303 (6815): : 1479 - 1479
  • [6] AID TO MEASUREMENT OF CENTRAL VENOUS PRESSURE
    SCOTT, PV
    BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (11) : 1025 - &
  • [7] CENTRAL-VENOUS-PRESSURE MEASUREMENT
    BENZIE, RJ
    SMITH, I
    LANCET, 1971, 1 (7711): : 1241 - &
  • [8] Noninvasive Measurement of Central Venous Pressure
    Ward, Kevin
    Tiba, Mohamad
    Draucker, Gerald
    Gunnerson, Kyle
    Barbee, Robert
    Reynolds, Penny
    Spiess, Bruce
    Ivatury, Rao
    CIRCULATION, 2009, 120 (18) : S1460 - S1460
  • [9] MEASUREMENT OF CENTRAL VENOUS-PRESSURE
    AMOROSO, P
    BRITISH MEDICAL JOURNAL, 1991, 303 (6808): : 994 - 994
  • [10] CENTRAL VENOUS-PRESSURE MEASUREMENT
    SINAPIUS, D
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1973, 98 (28) : 1383 - 1383