Dimensional change in complete dentures fabricated by injection molding and microwave processing

被引:50
|
作者
Keenan, PLJ [1 ]
Radford, DR [1 ]
Clark, RKF [1 ]
机构
[1] Kings Coll London, Guys Kings & St Thomas Dent Inst, Dept Fixed & Removable Prosthodont, London SE1 9RT, England
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2003年 / 89卷 / 01期
关键词
D O I
10.1067/mpr.2003.3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Acrylic resin complete dentures undergo dimensional changes during polymerization. Techniques with injection molding and polymerization and microwave polymerization are reported to reduce these changes and thereby improve clinical fit. These dimensional changes need to be quantified. Purpose. The purpose of this study was to compare differences in dimensional changes of simulated maxillary complete dentures during polymerization and storage in water after injection molding and conventional polymerization, or microwave polymerization against a control of conventionally packed and polymerized simulated maxillary complete dentures. Material and methods. Forty identical maxillary denture bases were prepared in dental wax with anatomic teeth. They were invested and the wax eliminated from the molds. Ten specimens each were randomly assigned to 1 of 4 groups. Group 1 was compression molded and conventionally polymerized; group 2 was injection molded and conventionally polymerized (Success); group 3 was injection molded and microwave polymerized (Acron MC); and group 4 was injection molded and microwave polymerized (Microbase). Intermolar width and changes in vertical dimension of occlusion, were determined after polymerization and after storage in water for 28 days. Measurements in triplicate were made between points scribed on the second molar teeth with a traveling microscope (accurate to 0.005 mm). Vertical dimension of occlusion was measured between points scribed on the upper and lower members of an articulator by use of an internal micrometer (accurate to 0.05 mm). Data were analyzed by use of a 1-way analysis of variance with Tukey post-hoc contrasts (P<.05). Results. Polymerization contractions (intermolar widths) for each group were: group 1, -0.24%; group 2, -0.27%; group 3, -0.35%; and group 4, -0.37%. The Microbase specimens had greater shrinkage than conventionally polymerized specimens, but there were no significant differences between the groups. All injection methods had less postpolymerization increase in vertical dimension of occlusion (0.63 to 0.41 mm) than the conventional Trevalon control (0.74 mm), but only group 4 was significantly different (P<.004). After storage in water for 28 days, all specimens increased in vertical dimension of occlusion (0.10% to 0.16%) from polymerization techniques, but there were no significant differences between groups. Conclusion. Within the limitations of this study, injection molding resulted in a slightly less increase of vertical dimension of occlusion than conventional polymerization techniques, the difference being significant for Microbase compared with the conventional Trevalon control.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 50 条
  • [1] Dimensional change of complete dentures produced by injection moulding
    Keenan, PLJ
    Radford, DR
    Clark, RKF
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 370 - 370
  • [2] COMPARISON OF INTERFACIAL SURFACE TENSION AND CAPILLARITY OF MAXILLARY COMPLETE DENTURES, FABRICATED BY CONVENTIONAL CUVETTE TECHNIQUE AND INJECTION MOLDING TECHNOLOGY
    Georgieva, Kalina
    Abadjiev, Metodi
    Kostadinov, Georgi
    Gogushev, Kiril
    JOURNAL OF IMAB, 2016, 22 (03): : 1296 - 1300
  • [3] PROCESSING COMPLETE DENTURES
    WOELFEL, JB
    DENTAL CLINICS OF NORTH AMERICA, 1977, 21 (02) : 329 - 338
  • [4] CHANGES IN VERTICAL DIMENSION OF OCCLUSION IN CONVENTIONAL AND MICROWAVE PROCESSING OF COMPLETE DENTURES
    NELSON, MW
    KOTWAL, KR
    SEVEDGE, SR
    JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (02): : 306 - 308
  • [5] Dimensional changes of complete dentures fabricated by milled and printed techniques: An in vitro study
    Tsai, Fu-Chuan
    Yang, Tsung-Chieh
    Wang, Tong-Mei
    Lin, Li-Deh
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (04): : 608 - 615
  • [6] Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling
    Einarsdottir, Erna R.
    Geminiani, Alessandro
    Chochlidakis, Konstantinos
    Feng, Changyong
    Tsigarida, Alexandra
    Ercoli, Carlo
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (01): : 116 - 121
  • [7] Occlusion vertical dimension changes in microwave and conventional processing of complete dentures.
    Barbosa, DB
    Compagnoni, MA
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A156 - A156
  • [8] A method to reduce tooth movement of complete dentures during microwave irradiation processing
    Rizzatti-Barbosa, CM
    Machado, C
    Joia, FA
    Sousa, RLDS
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 94 (03): : 301 - 302
  • [9] INARTICULATION OF COMPLETE DENTURES PROCESSED BY THE COMPRESSION MOLDING TECHNIQUE
    MAHLER, DB
    JOURNAL OF PROSTHETIC DENTISTRY, 1951, 1 (05): : 551 - 559
  • [10] Influence of Microwave Disinfection on the Linear Dimensional Stability of Complete Dentures: A Clinical Study
    Manzolli Basso, Michael Frederico
    Giampaolo, Eunice Teresinha
    Vergani, Carlos Eduardo
    Machado, Ana Lucia
    Pavarina, Ana Claudia
    Compagnoni, Marco Antonio
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) : 318 - 320