Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling

被引:18
|
作者
Einarsdottir, Erna R. [1 ]
Geminiani, Alessandro [2 ]
Chochlidakis, Konstantinos [3 ]
Feng, Changyong [4 ]
Tsigarida, Alexandra [5 ]
Ercoli, Carlo [3 ,5 ]
机构
[1] Univ Iceland, Dept Prosthodont, Reykjavik, Iceland
[2] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont & Periodontol, Rochester, NY 14620 USA
[3] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, 625 Elmwood Ave,Box 683, Rochester, NY 14620 USA
[4] Univ Rochester, Dept Biostat & Computat Biol, Rochester, NY 14620 USA
[5] Univ Rochester, Eastman Inst Oral Hlth, Dept Periodontol, Rochester, NY 14620 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2020年 / 124卷 / 01期
关键词
RESIN;
D O I
10.1016/j.prosdent.2019.09.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Studies evaluating the dimensional stability of denture bases fabricated by the double processing method are lacking. Purpose. The purpose of this in vitro study was to evaluate the dimensional stability of denture bases fabricated by 3 different techniques: compression molding, injection molding, and computer-aided design and computer-aided manufacturing (CAD-CAM) subtraction milling. Material and methods. Forty-five mandibular denture bases were fabricated from a master cast by a standardized process. A double processing protocol was used with 3 methods: compression molding (PRESS), injection molding (INJECT), or CAD-CAM (CAD). The bases were compared with the titanium master cast after the first processing. By a digital subtraction process, the dimensional stability of the bases was measured at 22 different locations on the intaglio surface. Denture teeth were then positioned according to a standardized protocol, and the denture was processed a second time and finished. The dimensional discrepancy was reassessed after the second processing and compared with the titanium master cast. Results. In all groups, most of the dimensional changes occurred during the first processing (P<.05), with no statistically significant deformation occurring during the second processing (P>.05). The CAD group presented significantly smaller dimensional changes than PRESS (P<.05) and INJECT (P<.05) groups. No significant difference was found in the dimensional stability in the PRESS and INJECT groups (P>.05). Conclusions. Denture bases fabricated by a CAD-CAM methodology exhibit fewer dimensional changes than either compression or injection molding. Distortion occurred during the fabrication of the denture base, and a second processing did not significantly affect the dimensional stability of the denture base.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 9 条
  • [1] Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method
    Lee, Suji
    Hong, Seoung-Jin
    Paek, Janghyun
    Pae, Ahran
    Kwon, Kung-Rock
    Noh, Kwantae
    JOURNAL OF ADVANCED PROSTHODONTICS, 2019, 11 (01): : 55 - 64
  • [2] Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study
    You, Seung-Gyu
    You, Seung-Min
    Kang, Seen-Young
    Bae, So-Yeon
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 479 - 485
  • [3] Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study
    Helal, Mohamed Ahmed
    Abdelrahim, Ramy Abdallah
    Zeidan, Ahmed Abd El-latif
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 11 - 19
  • [4] Accuracy of surface adaptation of complete denture bases fabricated using milling, material jetting, selective laser sintering, digital light processing, and conventional injection molding
    Schubert, Oliver
    Edelhoff, Daniel
    Erdelt, Kurt-Juergen
    Nold, Ephraim
    Gueth, Jan-Frederik
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (02) : 151 - 159
  • [5] Dimensional reliability in CAD/CAM production of complete denture bases: A comparative study of milling and various 3D printing technologies
    Graf, Tobias
    Schweiger, Josef
    Goob, Janosch
    Stimmelmayr, Michael
    Lente, Isabel
    Schubert, Oliver
    Dental Materials Journal, 2024, 43 (05): : 629 - 636
  • [6] Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases
    Emam, Abdel-Naser M.
    El-Esawy, Ahmed Ayman
    Alyami, Mohammed Hamad
    Baraka, Yasser
    Gad, Mohammed M.
    Helal, Mohamed Ahmed
    DENTISTRY JOURNAL, 2024, 12 (02)
  • [7] Improving wear resistance of acrylic resin denture teeth by using zirconia complete crowns fabricated with a CAD-CAM double-scanning method: A clinical report
    Lee, Eun-Hyuk
    Lim, Young-Jun
    Kwon, Ho-Beom
    Kim, Myung-Joo
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (03): : 273 - 277
  • [8] An In-Vitro Study to Evaluate the Effect of Denture Cleansing Agents on Color Stability of Denture Bases Fabricated Using CAD/CAM Milling, 3D-Printing and Conventional Techniques
    Jain, Saurabh
    Sayed, Mohammed
    Ahmed, Walaa Magdy
    Halawi, Amjad Hussain Asiri
    Najmi, Naif Mohammed Ahmed
    Aggarwal, Aparna
    Bhandi, Shilpa
    Patil, Shankargouda
    COATINGS, 2021, 11 (08)
  • [9] An In-Vitro Study to Evaluate the Effect of Denture Cleansing Agents on Color Stability of Denture Bases Fabricated Using CAD/CAM Milling, 3D-Printing and Conventional Techniques (vol 11, 962, 2021)
    Jain, Saurabh
    Sayed, Mohammed
    Ahmed, Walaa Magdy
    Halawi, Amjad Hussain Asiri
    Najmi, Naif Mohammed Ahmed
    Aggarwal, Aparna
    Bhandi, Shilpa
    Patil, Shankargouda
    COATINGS, 2021, 11 (10)