Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study

被引:13
|
作者
Helal, Mohamed Ahmed [1 ]
Abdelrahim, Ramy Abdallah [2 ]
Zeidan, Ahmed Abd El-latif [3 ]
机构
[1] Al Azhar Univ, Fac Med Dent, Dept Removable Prosthodont, AlmokhyamAldaem St,Nasr Rd, Cairo 11884, Egypt
[2] Al Azhar Univ, Fac Med Dent, Dept Dent Biomat, Cairo, Egypt
[3] Badr Univ, Dept Removable Prosthodont, Fac Dent, Cairo, Egypt
关键词
Digital dentures; subtractive technique; CAD-CAM; milled denture; CAD; CAM; additive technique; rapid prototyping; superimposition technique; FABRICATING COMPLETE DENTURES; ADAPTATION; ACCURACY; FUTURE;
D O I
10.1111/jopr.13538
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose This study compared the dimensional changes between computer-aided design and computer-aided manufacturing (CAD-CAM) milled complete denture bases (CDBs) and three-dimensional (3D) printed CDBs. Materials and methods One maxillary completely edentulous stone model was fabricated with three reference points at the incisive papilla, right molar, and left molar areas marked as X, Y, and Z, respectively. It was scanned to produce a standard tessellation language (STL) file, which was imported to a metal milling machine software to produce the metal model. This metal model was used to fabricate 30 CDBs for analysis. The CDBs were divided into three groups (n = 10 each) according to the fabrication method used as follows: Group 1, CAD-CAM milled CDBs; Group 2, 3D printed CDBs; and Group 3, conventional compression molded CDBs. The CDBs of all groups were scanned after fabrication, and the dimensional changes in each were evaluated by two methods. The first was the two-dimensional evaluation method that involved linear measurement of the distances between the reference points (X-Y, X-Z, and Y-Z) of the scanned reference cast and dentures. The second method was the 3D evaluation method that involved the superimposition of the STL files of the dentures on the STL file of the reference cast. Data were calculated and were statistically analyzed using one-way analysis of variance and Tukey's pairwise post hoc tests. Results There was a significant difference in the dimensional accuracy between the CAD-CAM milled, 3D printed, and conventional compression molded CDBs (p < 0.05). Conclusion The dimensional accuracy of the CAD-CAM milling system in complete denture fabrication is superior to that of the compression molding and 3D printing systems.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 50 条
  • [1] Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study
    You, Seung-Gyu
    You, Seung-Min
    Kang, Seen-Young
    Bae, So-Yeon
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 479 - 485
  • [2] Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases
    Emam, Abdel-Naser M.
    El-Esawy, Ahmed Ayman
    Alyami, Mohammed Hamad
    Baraka, Yasser
    Gad, Mohammed M.
    Helal, Mohamed Ahmed
    DENTISTRY JOURNAL, 2024, 12 (02)
  • [3] Complete denture fabrication with CAD/CAM record bases
    McLaughlin, J. Bryan
    Ramos, Van, Jr.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04): : 493 - 497
  • [4] A method to improve positioning of denture teeth on denture bases for CAD-CAM complete dentures: A dental technique
    Feng, Yue
    Ma, Sai
    Zhong, Sheng
    Niu, Lina
    Feng, Zhihong
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01): : 46 - 50
  • [5] Effect of denture cleansers on the physical and mechanical properties of CAD-CAM milled and 3D printed denture base materials: An in vitro study
    Hanno, Kenda I.
    Abdul-Monem, Mohamed M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 798.e1 - 798.e8
  • [6] Dimensional reliability in CAD/CAM production of complete denture bases: A comparative study of milling and various 3D printing technologies
    Graf, Tobias
    Schweiger, Josef
    Goob, Janosch
    Stimmelmayr, Michael
    Lente, Isabel
    Schubert, Oliver
    Dental Materials Journal, 2024, 43 (05): : 629 - 636
  • [7] Color Stability Determination of CAD/CAM Milled and 3D Printed Acrylic Resins for Denture Bases: A Narrative Review
    Dimitrova, Mariya
    Corsalini, Massimo
    Kazakova, Rada
    Vlahova, Angelina
    Barile, Giuseppe
    Dell'Olio, Fabio
    Tomova, Zlatina
    Kazakov, Stoyan
    Capodiferro, Saverio
    JOURNAL OF COMPOSITES SCIENCE, 2022, 6 (07):
  • [8] Fracture toughness of conventional, milled and 3D printed denture bases
    Mann, Ravdeep S.
    Ruse, N. Dorin
    DENTAL MATERIALS, 2022, 38 (09) : 1443 - 1451
  • [9] Intaglio surface of CNC milled versus 3D printed maxillary complete denture bases - An in vitro investigation of the accuracy of seven systems
    Cameron, Andrew B.
    Kim, Harry
    Evans, Jane L.
    Abuzar, Menaka A.
    Tadakamadla, Santosh Kumar
    Alifui-Segbaya, Frank
    JOURNAL OF DENTISTRY, 2024, 151
  • [10] Efficacy of denture cleansers on Candida albicans adhesion and their effects on the properties of conventional, milled CAD/CAM, and 3D-printed denture bases
    Bento, Victor Augusto Alves
    Sayeg, Joao Mateus Cavalaro
    Rosa, Cleber Davi Del Rei Daltro
    Lopes, Leonardo Ferreira de Toledo Piza
    Marques, Maria Carolina Silva
    Pellizzer, Eduardo Piza
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (07)