Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study

被引:13
|
作者
Helal, Mohamed Ahmed [1 ]
Abdelrahim, Ramy Abdallah [2 ]
Zeidan, Ahmed Abd El-latif [3 ]
机构
[1] Al Azhar Univ, Fac Med Dent, Dept Removable Prosthodont, AlmokhyamAldaem St,Nasr Rd, Cairo 11884, Egypt
[2] Al Azhar Univ, Fac Med Dent, Dept Dent Biomat, Cairo, Egypt
[3] Badr Univ, Dept Removable Prosthodont, Fac Dent, Cairo, Egypt
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2023年 / 32卷
关键词
Digital dentures; subtractive technique; CAD-CAM; milled denture; CAD; CAM; additive technique; rapid prototyping; superimposition technique; FABRICATING COMPLETE DENTURES; ADAPTATION; ACCURACY; FUTURE;
D O I
10.1111/jopr.13538
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose This study compared the dimensional changes between computer-aided design and computer-aided manufacturing (CAD-CAM) milled complete denture bases (CDBs) and three-dimensional (3D) printed CDBs. Materials and methods One maxillary completely edentulous stone model was fabricated with three reference points at the incisive papilla, right molar, and left molar areas marked as X, Y, and Z, respectively. It was scanned to produce a standard tessellation language (STL) file, which was imported to a metal milling machine software to produce the metal model. This metal model was used to fabricate 30 CDBs for analysis. The CDBs were divided into three groups (n = 10 each) according to the fabrication method used as follows: Group 1, CAD-CAM milled CDBs; Group 2, 3D printed CDBs; and Group 3, conventional compression molded CDBs. The CDBs of all groups were scanned after fabrication, and the dimensional changes in each were evaluated by two methods. The first was the two-dimensional evaluation method that involved linear measurement of the distances between the reference points (X-Y, X-Z, and Y-Z) of the scanned reference cast and dentures. The second method was the 3D evaluation method that involved the superimposition of the STL files of the dentures on the STL file of the reference cast. Data were calculated and were statistically analyzed using one-way analysis of variance and Tukey's pairwise post hoc tests. Results There was a significant difference in the dimensional accuracy between the CAD-CAM milled, 3D printed, and conventional compression molded CDBs (p < 0.05). Conclusion The dimensional accuracy of the CAD-CAM milling system in complete denture fabrication is superior to that of the compression molding and 3D printing systems.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 50 条
  • [31] Comparison of Denture Base Adaptation and Some Mechanical Properties among Conventional, CAD-CAM, and 3-D Printed Denture Base Materials
    abdul-allah, Ameer Yousif
    abdulsahib, Ali Jameel
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (07):
  • [32] Evaluation of the Influence of Build Orientation on the Surface Roughness and Flexural Strength of 3D-Printed Denture Base Resin and Its Comparison with CAD-CAM Milled Denture Base Resin
    Alharethi, Naji Ahmad
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (01) : 321 - 328
  • [33] Evaluation of the Effect of Different Construction Techniques of CAD-CAM Milled, 3D-Printed, and Polyamide Denture Base Resins on Flexural Strength: An In Vitro Comparative Study
    Zeidan, Ahmed Abd El-Latif
    Sherif, Ahmed Fadlallah
    Baraka, Yasser
    Abualsaud, Reem
    Abdelrahim, Ramy Abdallah
    Gad, Mohammed M.
    Helal, Mohamed A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 77 - 82
  • [34] Effects of aging on attachment of Candida albicans to conventional heat-polymerized, CAD-CAM milled, and CAD-CAM 3D-printed acrylic resin bases
    Jung, Gabrielle K.
    Mora, Stephanie N.
    Yune, Stephen S.
    Petrich, Anton
    Hernandez-Feldpausch, Marina
    Hamlin, Christopher M.
    Tuamokumo, Francois O.
    Kim, Jeffrey J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [35] Bond Strength of Denture Teeth to Heat-Cured, CAD/CAM and 3D Printed Denture Acrylics
    Choi, Joanne Jung Eun
    Uy, Caira Ellyse
    Plaksina, Polina
    Ramani, Rishi Sanjay
    Ganjigatti, Ritu
    Waddell, John Neil
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (05): : 415 - 421
  • [36] Dimensional Stability of Complete Denture Permanent Acrylic Resin Denture Bases; A Comparison of Dimensions Before and After a Second Curing Cycle
    Fenlon, Michael Robert
    Juszczyk, Andrzej Stanislaw
    Rodriguez, Jose Mauricio
    Curtis, Richard Victor
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2010, 18 (01): : 33 - 38
  • [37] Effect of mechanical and chemical surface treatments on the repairing of milled and 3D-printed denture bases
    Htat, Hein Linn
    Prawatvatchara, Wisarut
    Techapiroontong, Siraphob
    Lee, Jae-Hyun
    Limpuangthip, Nareudee
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [38] In-vitro Comparative Evaluation for the Surface Properties and Impact Strength of CAD/CAM Milled, 3D Printed, and Polyamide Denture Base Resins
    Helal, Mohamed A.
    Fadl-Alah, Ahmed
    Baraka, Yasser M.
    Gad, Mohammed M.
    Emam, Abdel-Naser M.
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2022, 12 (01): : 126 - 131
  • [39] A comparative evaluation of physical properties of CAD/CAM complete denture resins- an in vitro study
    Arora, Ojasvini
    Ahmed, Nabeel
    Siurkel, Yuliia
    Ronsivalle, Vincenzo
    Cicciu, Marco
    Minervini, Giuseppe
    BMC ORAL HEALTH, 2024, 24 (01)
  • [40] A comparative evaluation of physical properties of CAD/CAM complete denture resins- an in vitro study
    Ojasvini Arora
    Nabeel Ahmed
    Yuliia Siurkel
    Vincenzo Ronsivalle
    Marco Cicciù
    Giuseppe Minervini
    BMC Oral Health, 24