Dimensional change in complete dentures fabricated by injection molding and microwave processing

被引:50
|
作者
Keenan, PLJ [1 ]
Radford, DR [1 ]
Clark, RKF [1 ]
机构
[1] Kings Coll London, Guys Kings & St Thomas Dent Inst, Dept Fixed & Removable Prosthodont, London SE1 9RT, England
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2003年 / 89卷 / 01期
关键词
D O I
10.1067/mpr.2003.3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Acrylic resin complete dentures undergo dimensional changes during polymerization. Techniques with injection molding and polymerization and microwave polymerization are reported to reduce these changes and thereby improve clinical fit. These dimensional changes need to be quantified. Purpose. The purpose of this study was to compare differences in dimensional changes of simulated maxillary complete dentures during polymerization and storage in water after injection molding and conventional polymerization, or microwave polymerization against a control of conventionally packed and polymerized simulated maxillary complete dentures. Material and methods. Forty identical maxillary denture bases were prepared in dental wax with anatomic teeth. They were invested and the wax eliminated from the molds. Ten specimens each were randomly assigned to 1 of 4 groups. Group 1 was compression molded and conventionally polymerized; group 2 was injection molded and conventionally polymerized (Success); group 3 was injection molded and microwave polymerized (Acron MC); and group 4 was injection molded and microwave polymerized (Microbase). Intermolar width and changes in vertical dimension of occlusion, were determined after polymerization and after storage in water for 28 days. Measurements in triplicate were made between points scribed on the second molar teeth with a traveling microscope (accurate to 0.005 mm). Vertical dimension of occlusion was measured between points scribed on the upper and lower members of an articulator by use of an internal micrometer (accurate to 0.05 mm). Data were analyzed by use of a 1-way analysis of variance with Tukey post-hoc contrasts (P<.05). Results. Polymerization contractions (intermolar widths) for each group were: group 1, -0.24%; group 2, -0.27%; group 3, -0.35%; and group 4, -0.37%. The Microbase specimens had greater shrinkage than conventionally polymerized specimens, but there were no significant differences between the groups. All injection methods had less postpolymerization increase in vertical dimension of occlusion (0.63 to 0.41 mm) than the conventional Trevalon control (0.74 mm), but only group 4 was significantly different (P<.004). After storage in water for 28 days, all specimens increased in vertical dimension of occlusion (0.10% to 0.16%) from polymerization techniques, but there were no significant differences between groups. Conclusion. Within the limitations of this study, injection molding resulted in a slightly less increase of vertical dimension of occlusion than conventional polymerization techniques, the difference being significant for Microbase compared with the conventional Trevalon control.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 50 条
  • [41] Dimensional Distortion in Injection Molding.
    Fedele, Raffaele
    Materie plastiche ed elastomeri, 1979, (7-8): : 399 - 404
  • [42] Relative influence of injection molding processing conditions on HDPE acetabular cups dimensional stability
    Zhil'tsova, T. V.
    Oliveira, M. S. A.
    Ferreira, J. A. F.
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2009, 209 (08) : 3894 - 3904
  • [43] Accuracy of surface adaptation of complete denture bases fabricated using milling, material jetting, selective laser sintering, digital light processing, and conventional injection molding
    Schubert, Oliver
    Edelhoff, Daniel
    Erdelt, Kurt-Juergen
    Nold, Ephraim
    Gueth, Jan-Frederik
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (02) : 151 - 159
  • [44] Assessment of CAD-CAM polymers for digitally fabricated complete dentures
    Perea-Lowery, Leila
    Minja, Irene K.
    Lassila, Lippo
    Ramakrishnaiah, Ravikumar
    Vallittu, Pekka K.
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (01): : 175 - 181
  • [45] DIMENSIONAL STABILITY IN PROCESSING REMOVABLE PARTIAL DENTURES
    ADAIR, PJ
    GILDENHU.RR
    STALLARD, RE
    JOURNAL OF DENTAL RESEARCH, 1974, 53 (FEB) : 278 - 278
  • [46] MONITORING DIMENSIONAL CHANGES IN PROCESSED ACRYLIC COMPLETE DENTURES
    LECHNER, SK
    LAUTENSCHLAGER, EP
    JOURNAL OF DENTAL RESEARCH, 1983, 62 : 661 - 661
  • [47] Growth of Candida species on complete dentures: effect of microwave disinfection
    Sanita, Paula Volpato
    Vergani, Carlos Eduardo
    Giampaolo, Eunice Teresinha
    Pavarina, Ana Claudia
    Machado, Ana Lucia
    MYCOSES, 2009, 52 (02) : 154 - 160
  • [48] COMPARISON OF THE DIMENSIONAL STABILITY OF 2 WAXES AND 2 ACRYLIC RESIN PROCESSING TECHNIQUES IN THE PRODUCTION OF COMPLETE DENTURES
    SYKORA, O
    SUTOW, EJ
    JOURNAL OF ORAL REHABILITATION, 1990, 17 (03) : 219 - 227
  • [49] Microwave Disinfection of Complete Dentures Contaminated In Vitro with Selected Bacteria
    Dovigo, Livia Nordi
    Pavarina, Ana Claudia
    Ribeiro, Daniela Garcia
    de Oliveira, Juliana Aparecida
    Vergani, Carlos Eduardo
    Machado, Ana Lucia
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (07): : 611 - 617
  • [50] Accuracy of trial complete dentures fabricated by using fused deposition modeling 3-dimensional printing: An in vitro study
    Lo Russo, Lucio
    Lo Muzio, Eleonora
    Troiano, Giuseppe
    Salamini, Angelo
    Zhurakivska, Khrystyna
    Guida, Laura
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 908 - 912