Dimensional change in complete dentures fabricated by injection molding and microwave processing

被引:50
|
作者
Keenan, PLJ [1 ]
Radford, DR [1 ]
Clark, RKF [1 ]
机构
[1] Kings Coll London, Guys Kings & St Thomas Dent Inst, Dept Fixed & Removable Prosthodont, London SE1 9RT, England
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2003年 / 89卷 / 01期
关键词
D O I
10.1067/mpr.2003.3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Acrylic resin complete dentures undergo dimensional changes during polymerization. Techniques with injection molding and polymerization and microwave polymerization are reported to reduce these changes and thereby improve clinical fit. These dimensional changes need to be quantified. Purpose. The purpose of this study was to compare differences in dimensional changes of simulated maxillary complete dentures during polymerization and storage in water after injection molding and conventional polymerization, or microwave polymerization against a control of conventionally packed and polymerized simulated maxillary complete dentures. Material and methods. Forty identical maxillary denture bases were prepared in dental wax with anatomic teeth. They were invested and the wax eliminated from the molds. Ten specimens each were randomly assigned to 1 of 4 groups. Group 1 was compression molded and conventionally polymerized; group 2 was injection molded and conventionally polymerized (Success); group 3 was injection molded and microwave polymerized (Acron MC); and group 4 was injection molded and microwave polymerized (Microbase). Intermolar width and changes in vertical dimension of occlusion, were determined after polymerization and after storage in water for 28 days. Measurements in triplicate were made between points scribed on the second molar teeth with a traveling microscope (accurate to 0.005 mm). Vertical dimension of occlusion was measured between points scribed on the upper and lower members of an articulator by use of an internal micrometer (accurate to 0.05 mm). Data were analyzed by use of a 1-way analysis of variance with Tukey post-hoc contrasts (P<.05). Results. Polymerization contractions (intermolar widths) for each group were: group 1, -0.24%; group 2, -0.27%; group 3, -0.35%; and group 4, -0.37%. The Microbase specimens had greater shrinkage than conventionally polymerized specimens, but there were no significant differences between the groups. All injection methods had less postpolymerization increase in vertical dimension of occlusion (0.63 to 0.41 mm) than the conventional Trevalon control (0.74 mm), but only group 4 was significantly different (P<.004). After storage in water for 28 days, all specimens increased in vertical dimension of occlusion (0.10% to 0.16%) from polymerization techniques, but there were no significant differences between groups. Conclusion. Within the limitations of this study, injection molding resulted in a slightly less increase of vertical dimension of occlusion than conventional polymerization techniques, the difference being significant for Microbase compared with the conventional Trevalon control.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 50 条
  • [21] THERMOSET PROCESSING IN INJECTION MOLDING
    HAUENSTEIN, K
    KUNSTSTOFFE-PLASTICS, 1971, 18 (03): : 101 - +
  • [22] PROCESSING FACTS - INJECTION MOLDING
    不详
    PLASTICS WORLD, 1969, 27 (01): : 41 - &
  • [23] INJECTION MOLDING PROCESSING OF ELASTOMERES
    MUHR, R
    KUNSTSTOFFE-PLASTICS, 1974, 21 (07): : 18 - 22
  • [24] Warpage Characterization of Microchannels Fabricated by Injection Molding
    Cetin, Barbaros
    Koska, A. Koray
    Erdal, Merve
    JOURNAL OF MICRO AND NANO-MANUFACTURING, 2015, 3 (02):
  • [25] Photorefractive polymer composites fabricated by injection molding
    Herlocker, JA
    Fuentes-Hernandez, C
    Wang, JF
    Peyghambarian, N
    Kippelen, B
    Zhang, Q
    Marder, SR
    APPLIED PHYSICS LETTERS, 2002, 80 (07) : 1156 - 1158
  • [26] DOUBLE-PROCESSING TECHNIQUE FOR COMPLETE DENTURES
    VILLA, HA
    JOURNAL OF PROSTHETIC DENTISTRY, 1969, 22 (04): : 500 - &
  • [27] PROCESSING COMPLETE DENTURES WITHOUT TOOTH MOVEMENT
    RUDD, KD
    DENTAL CLINICS OF NORTH AMERICA, 1964, (NOV) : 675 - &
  • [28] CHANGES CAUSED BY PROCESSING COMPLETE MANDIBULAR DENTURES
    LECHNER, SK
    THOMAS, GA
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (06): : 606 - 613
  • [29] Assessment of Conventionally and Digitally Fabricated Complete Dentures: A Comprehensive Review
    Mubaraki, Manal Q.
    Al Moaleem, Mohammed M.
    Alzahrani, Abdulrahman H.
    Shariff, Mansoor
    Alqahtani, Saeed M.
    Porwal, Amit
    Al-Sanabani, Fuad A.
    Bhandi, Shilpa
    Tribst, Joao Paulo Mendes
    Heboyan, Artak
    Patil, Shankargouda
    MATERIALS, 2022, 15 (11)
  • [30] Virtual evaluation for CAD-CAM-fabricated complete dentures
    Schweiger, Josef
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Stumbaum, Juliane
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (01): : 28 - 33