Simultaneous Hip Head-Stem Taper Junction Measurements of Electrochemical Corrosion and Micromotion: A Comparison of Taper Geometry and Stem Material

被引:2
|
作者
Swaminathan, V. [1 ]
Scholl, L. [1 ]
Lee, R. [1 ]
Faizan, A. [1 ]
Thakore, M. [1 ]
TenHuisen, K. [1 ]
Nevelos, J. [1 ]
机构
[1] Stryker Orthopaed, 325 Corp Dr, Mahwah, NJ 07430 USA
关键词
corrosion; micromotion; electrochemistry; onset load; tapers; FRETTING CORROSION; CREVICE CORROSION; INTERFACE;
D O I
10.1520/STP159120140150
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fretting corrosion or mechanically assisted crevice corrosion is a current topic of research in total hip arthroplasty highlighted by the modularity of the head-neck taper junction. The extent of corrosion may be influenced by a multitude of factors, and in this study, we examined two specific variables: material combination and taper geometry. Corrosion performance was quantitatively assessed by measuring fretting corrosion at the taper junction as well as relative micromotion between the head and stem components. To examine the effect of material combinations, stems composed of either Ti-6AI-4V or TMZF (R) were tested with CoCrMo femoral heads. To study taper geometry, a V40 (TM) taper design was compared with a C-taper design. Cyclic fatigue loading was applied to the test specimens, increasing load from 100 to 3200 N and then continuing loading to 1 million cycles. All tests were performed in phosphate-buffered saline solution at room temperature and electrochemical data analysis included determination of onset load, average current, average open-circuit potential, peak-to-peak current, and absolute change in potential. Micromotion fixtures were attached rigidly to the head and proximal stem. The micromotion output was used to calculate pistoning of the head along the stem, rocking of the head about the stem, and subsidence (or seating or slipping) of the head against the stem. The electrochemical data showed that the mean onset load for different groups was in the range of 1075 to 1194 N and average currents up to 2 mu A were recorded for different sample groups during cyclic loading. Fretting corrosion and micromotion measurements in this study showed that the variation produced by material combination and taper design within the range of test groups tested were less than the variation that existed in each test group.
引用
收藏
页码:321 / 335
页数:15
相关论文
共 48 条
  • [21] Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study
    Arnholt, Christina M.
    MacDonald, Daniel W.
    Underwood, Richard J.
    Guyer, Eric P.
    Rimnac, Clare M.
    Kurtz, Steven M.
    Mont, Michael A.
    Klein, Gregg R.
    Lee, Gwo-Chin
    Chen, Antonia F.
    Hamlin, Brian R.
    Cates, Harold E.
    Malkani, Arthur L.
    Kraay, Matthew J.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (04): : 1363 - 1373
  • [22] Analysis of modular taper fractures of the revision hip stem Prevision and comparison of the original and current taper design
    Dreyer, L.
    Bader, C.
    Floerkemeier, T.
    Wagner, M.
    BONE & JOINT JOURNAL, 2024, 106B (02): : 151 - 157
  • [23] Head-stem trunnion dissociation due to corrosion in total hip arthroplasty
    Whitehouse, Michael R.
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (17)
  • [24] Primary hip replacement stem taper fracture due to corrosion in 3 patients
    Morlock, Michael M.
    Buente, Dennis
    Ettema, Harmen
    Verheyen, Cees C.
    Hamberg, Ake
    Gilbert, Jeremy
    ACTA ORTHOPAEDICA, 2016, 87 (02) : 189 - 192
  • [25] Comparison of single taper and dual taper versions of the same stem design in total hip arthroplasty for primary osteoarthritis
    Francesco Castagnini
    Barbara Bordini
    Monica Cosentino
    Enrico Tassinari
    Giulia Guizzardi
    Francesco Traina
    Journal of Orthopaedics and Traumatology, 24
  • [26] Comparison of single taper and dual taper versions of the same stem design in total hip arthroplasty for primary osteoarthritis
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Tassinari, Enrico
    Guizzardi, Giulia
    Traina, Francesco
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 24 (01)
  • [27] The taper corrosion pattern observed for one bi-modular stem design is related to geometry-determined taper mechanics
    Buente, Dennis
    Bryant, Michael
    Ward, Michael
    Neville, Anne
    Morlock, Michael
    Huber, Gerd
    MEDICAL ENGINEERING & PHYSICS, 2017, 46 : 79 - 88
  • [28] Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head
    Nassutt, Roman
    Mollenhauer, Inken
    Klingbeil, Klaus
    Hennig, Oliver
    Grundei, Hans
    BIOMEDIZINISCHE TECHNIK, 2006, 51 (02): : 103 - 109
  • [29] Influence of stem type on material loss at the metal-on-metal pinnacle taper junction
    Hothi, Harry S.
    Whittaker, Robert K.
    Meswania, Jay M.
    Blunn, Gordon W.
    Skinner, John A.
    Hart, Alister J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (01) : 91 - 97
  • [30] The onset of fretting at the head-stem connection in hip arthroplasty is affected by head material and trunnion design under simulated corrosion conditions
    Rowan, Fiachra E.
    Wach, Amanda
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (06) : 1630 - 1636