Changes in Radial Artery Pulse Pressure During a Fluid Challenge Cannot Assess Fluid Responsiveness in Patients With Septic Shock

被引:5
|
作者
De la Puente-Diaz de Leon, Victor [1 ]
Jaramillo-Rocha, Valente de Jesus [2 ]
Teboul, Jean-Louis [3 ]
Garcia-Miranda, Sofia [4 ]
Martinez-Guerra, Bernardo A. [5 ]
Dominguez-Cherit, Guillermo [1 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Crit Care Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
[2] Univ Hlth Network, Toronto Gen Hosp, Interdept Div Crit Care, 585 Univ Ave, Toronto, ON M5G 2N2, Canada
[3] Univ Paris Sud, Bicetre Univ Hosp, Med Intens Care Unit, Paris, France
[4] Fdn Clin Med Sur, Dept Internal Med, Mexico City, DF, Mexico
[5] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Internal Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
关键词
fluid challenge; fluid responsiveness; radial pulse pressure; pulmonary artery catheter; cardiac output; septic shock; CARDIAC-OUTPUT; INTENSIVE-CARE;
D O I
10.1177/0885066617732291
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Arterial blood pressure is the most common variable used to assess the response to a fluid challenge in routine clinical practice. The aim of this study was to evaluate the accuracy of the change in the radial artery pulse pressure (rPP) to detect the change in cardiac output after a fluid challenge in patients with septic shock. Methods: Prospective observational study including 35 patients with septic shock in which rPP and cardiac output were measured before and after a fluid challenge with 400 mL of crystalloid solution. Cardiac output was measured with intermittent thermodilution technique using a pulmonary artery catheter. Patients were divided between responders (increase >15% of cardiac output after fluid challenge) and nonresponders. The area under the receiver operating characteristic curve (AUROC), Pearson correlation coefficient and paired Student t test were used in statistical analysis. Results: Forty-three percent of the patients were fluid responders. The change in rPP could not neither discriminate between responders and nonresponders (AUROC = 0.52; [95% confidence interval: 0.31-0.72] P = .8) nor correlate (r = .21, P = .1) with the change in cardiac output after the fluid challenge. Conclusions: The change in rPP neither discriminated between fluid responders and nonresponders nor correlated with the change in cardiac output after a fluid challenge. The change in rPP cannot serve as a surrogate of the change in cardiac output to assess the response to a fluid challenge in patients with septic shock.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [41] Pulse pressure variation: beyond the fluid management of patients with shock
    Frédéric Michard
    Marcel R Lopes
    Jose-Otavio C Auler
    Critical Care, 11
  • [42] Tolerability And Feasibility Of Passive Leg Raise To Assess Fluid Responsiveness And Fluid Toxicity In Septic Patients In A Mozambican Emergency Department
    Graves, S. K.
    Chambal, L.
    Loforte, D.
    Zavale, B.
    Palolite, N.
    Manguele, N.
    Zandamela, A.
    Smith, D. M.
    Fedullo, P. F.
    Patel, S.
    Urci, F.
    Akrami, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [43] CAROTID VELOCITY TIME INTEGRAL (VTI) AS A SURROGATE FOR FLUID RESPONSIVENESS IN PATIENTS WITH SEPTIC SHOCK
    Patel, Krunal H.
    Gorantla, Asher
    CHEST, 2022, 162 (04) : 891A - 891A
  • [44] Disturbed fluid responsiveness and lactate/pyruvate ratio as predictors for mortality of septic shock patients
    Mohamed, Ahmed Abdalla
    Essam, Ahmed
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2016, 32 (04): : 451 - 461
  • [45] Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness
    Mallat, J.
    Meddour, M.
    Durville, E.
    Lemyze, M.
    Pepy, F.
    Temime, J.
    Vangrunderbeeck, N.
    Tronchon, L.
    Thevenin, D.
    Tavernier, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 449 - 456
  • [46] Comparison between carotid corrected flow time changes in septic shock patients induced by fluid challenge tests
    Youssif, Islam Hamdy Elsayed
    Zaytoun, Tayseer Mohamed
    Fayed, Akram Muhammad
    Meligy, Haitham Saber
    Ghalab, Mahmoud Abdelaziz Abdelnaby
    ALEXANDRIA JOURNAL OF MEDICINE, 2025, 61 (01) : 208 - 214
  • [47] Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies
    Freitas, F. G. R.
    Bafi, A. T.
    Nascente, A. P. M.
    Assuncao, M.
    Mazza, B.
    Azevedo, L. C. P.
    Machado, F. R.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (03) : 402 - 408
  • [48] Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery
    Kramer, A
    Zygun, D
    Hawes, H
    Easton, P
    Ferland, A
    CHEST, 2004, 126 (05) : 1563 - 1568
  • [49] RELIABILITY OF CVP TO ASSESS LEFT VENTRICULAR PRELOAD FOR FLUID RESUSCITATION IN SEPTIC SHOCK PATIENTS
    Sasai, T.
    Tokioka, H.
    Iwasaki, E.
    Kawanoue, N.
    Fukushima, T.
    Mikane, T.
    Oku, S.
    Kobayashi, H.
    Ishii, M.
    Oishi, Y.
    INTENSIVE CARE MEDICINE, 2013, 39 : S478 - S479
  • [50] Pulse Pressure Variation Predicts Fluid Responsiveness in Elderly Patients After Coronary Artery Bypass Graft Surgery
    Yazigi, Alexandre
    Khoury, Eliane
    Hlais, Sani
    Madi-Jebara, Samia
    Haddad, Fadia
    Hayek, Gemma
    Jabbour, Khalil
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2012, 26 (03) : 387 - 390