Changes in Radial Artery Pulse Pressure During a Fluid Challenge Cannot Assess Fluid Responsiveness in Patients With Septic Shock

被引:5
|
作者
De la Puente-Diaz de Leon, Victor [1 ]
Jaramillo-Rocha, Valente de Jesus [2 ]
Teboul, Jean-Louis [3 ]
Garcia-Miranda, Sofia [4 ]
Martinez-Guerra, Bernardo A. [5 ]
Dominguez-Cherit, Guillermo [1 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Crit Care Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
[2] Univ Hlth Network, Toronto Gen Hosp, Interdept Div Crit Care, 585 Univ Ave, Toronto, ON M5G 2N2, Canada
[3] Univ Paris Sud, Bicetre Univ Hosp, Med Intens Care Unit, Paris, France
[4] Fdn Clin Med Sur, Dept Internal Med, Mexico City, DF, Mexico
[5] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Internal Med, Vasco de Quiroga 15, Mexico City, DF, Mexico
关键词
fluid challenge; fluid responsiveness; radial pulse pressure; pulmonary artery catheter; cardiac output; septic shock; CARDIAC-OUTPUT; INTENSIVE-CARE;
D O I
10.1177/0885066617732291
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Arterial blood pressure is the most common variable used to assess the response to a fluid challenge in routine clinical practice. The aim of this study was to evaluate the accuracy of the change in the radial artery pulse pressure (rPP) to detect the change in cardiac output after a fluid challenge in patients with septic shock. Methods: Prospective observational study including 35 patients with septic shock in which rPP and cardiac output were measured before and after a fluid challenge with 400 mL of crystalloid solution. Cardiac output was measured with intermittent thermodilution technique using a pulmonary artery catheter. Patients were divided between responders (increase >15% of cardiac output after fluid challenge) and nonresponders. The area under the receiver operating characteristic curve (AUROC), Pearson correlation coefficient and paired Student t test were used in statistical analysis. Results: Forty-three percent of the patients were fluid responders. The change in rPP could not neither discriminate between responders and nonresponders (AUROC = 0.52; [95% confidence interval: 0.31-0.72] P = .8) nor correlate (r = .21, P = .1) with the change in cardiac output after the fluid challenge. Conclusions: The change in rPP neither discriminated between fluid responders and nonresponders nor correlated with the change in cardiac output after a fluid challenge. The change in rPP cannot serve as a surrogate of the change in cardiac output to assess the response to a fluid challenge in patients with septic shock.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [21] Utility Of Central Venous Pressure And Shock Index In Predicting Hemodynamic Response To Fluid Challenge In Patients With Septic Shock
    Lanspa, M. J.
    Brown, S.
    Li, Y.
    Pittman, J. E.
    Jones, J.
    Grissom, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [22] Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation
    Perner, A.
    Faber, T.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) : 1068 - 1073
  • [23] The ability of pulse oximetry-derived peripheral perfusion index to detect fluid responsiveness in patients with septic shock
    Ahmed Hasanin
    Nadia Karam
    Ahmed M. Mukhtar
    Sara F. Habib
    Journal of Anesthesia, 2021, 35 : 254 - 261
  • [24] The ability of pulse oximetry-derived peripheral perfusion index to detect fluid responsiveness in patients with septic shock
    Hasanin, Ahmed
    Karam, Nadia
    Mukhtar, Ahmed M.
    Habib, Sara F.
    JOURNAL OF ANESTHESIA, 2021, 35 (02) : 254 - 261
  • [25] Optimal central venous pressure in fluid challenge in severe sepsis and septic shock
    Dobrin, BN
    Soldati, G
    Van Nuffelen, M
    Vincent, JL
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A166 - A166
  • [26] Study by transpulmonary thermodilution of fluid challenge response in patients with septic shock
    Puyoo, O
    Genestal, M
    Cougot, P
    Angles, O
    Charlet, JP
    INTENSIVE CARE MEDICINE, 2001, 27 : S148 - S148
  • [27] Reliability of central venous pressure to assess left ventricular preload for fluid resuscitation in patients with septic shock
    Sasai T.
    Tokioka H.
    Fukushima T.
    Mikane T.
    Oku S.
    Iwasaki E.
    Ishii M.
    Mieda H.
    Ishikawa T.
    Minami E.
    Journal of Intensive Care, 2 (1)
  • [28] PLETH VARIABILITY INDEX, PULSE PRESSURE AND STROKE VOLUME VARIATION DO NOT PREDICT FLUID RESPONSIVENESS IN VENTILATED PATIENTS WITH SEPTIC SHOCK TREATED WITH VASOPRESSORS
    Jagannathan, V. K.
    Sharma, S.
    Finn, P.
    Ryan, J.
    Mullenheim, J. W.
    INTENSIVE CARE MEDICINE, 2011, 37 : S89 - S89
  • [29] GEDVI and PPV predict fluid responsiveness in patients with ALI secondary to septic shock
    汪华玲
    ChinaMedicalAbstracts(InternalMedicine), 2014, 31 (02) : 86 - 86
  • [30] Effect of VTILVOT variation rate on the assessment of fluid responsiveness in septic shock patients
    Wang, Jinzhong
    Zhou, Dexing
    Gao, Yi
    Wu, Zhongyong
    Wang, Xiaozhi
    Lv, Chuanzhu
    MEDICINE, 2020, 99 (47) : E22702