Patient-specific simulation of guidewire deformation during transcatheter aortic valve implantation

被引:6
|
作者
Vy, Phuoc [1 ,2 ,3 ,4 ]
Auffret, Vincent [3 ,4 ,5 ]
Castro, Miguel [3 ,4 ]
Badel, Pierre [2 ]
Rochette, Michel [1 ]
Haigron, Pascal [3 ,4 ]
Avril, Stephane [2 ]
机构
[1] ANSYS France, F-69100 Villeurbanne, France
[2] Ecole Natl Super Mines, INSERM, SAINBIOSE, CIS,EMSE,U1059, F-42023 St Etienne, France
[3] INSERM, U1099, F-35000 Rennes, France
[4] Univ Rennes, LTSI, Campus Beaulieu Bat 22, F-35000 Rennes, France
[5] CHU Rennes, Serv Cardiol & Malad Vasc, F-35000 Rennes, France
关键词
CATHETER NAVIGATION; REPLACEMENT; STENOSIS; MANAGEMENT;
D O I
10.1002/cnm.2974
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcatheter aortic valve implantation is a recent mini-invasive procedure to implant an aortic valve prosthesis. Prosthesis positioning in transcatheter aortic valve implantation appears as an important aspect for the success of the intervention. Accordingly, we developed a patient-specific finite element framework to predict the insertion of the stiff guidewire, used to position the aortic valve. We simulated the guidewire insertion for 2 patients based on their pre-operative CT scans. The model was designed to primarily predict the position and the angle of the guidewires in the aortic valve, and the results were successfully compared with intraoperative images. The present paper describes extensively the numerical model, which was solved by using the ANSYS software with an implicit resolution scheme, as well as the stabilization techniques which were used to overcome numerical instabilities. We performed sensitivity analysis on the properties of the guidewire (curvature angle, curvature radius, and stiffness) and the conditions of insertion (insertion force and orientation). We also explored the influence of the model parameters. The accuracy of the model was quantitatively evaluated as the distance and the angle difference between the simulated guidewires and the intraoperative ones. A good agreement was obtained between the model predictions and intraoperative views available for 2 patient cases. In conclusion, we showed that the shape of the guidewire in the aortic valve was mainly determined by the geometry of the patient's aorta and by the conditions of insertion (insertion force and orientation).
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Transcatheter aortic valve implantation: patient selection
    Stortecky, S.
    O'Sullivan, C. J.
    Buellesfeld, L.
    Wenaweser, P.
    Windecker, S.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (05): : 487 - 497
  • [42] Patient-Specific Computer Modeling to Guide Redo Transcatheter Aortic Valve Replacement
    Dargan, James
    Kenawi, Abdelrahman
    Khan, Faisal
    Firoozi, Sami
    Brecker, Stephen
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (18) : 2332 - 2334
  • [43] Patient-Specific Computer Modeling to Predict Aortic Regurgitation After Transcatheter Aortic Valve Replacement
    de Jaegere, Peter
    De Santis, Gianluca
    Rodriguez-Olivares, Ramon
    Bosmans, Johan
    Bruining, Nico
    Dezutter, Tim
    Rahhab, Zouhair
    El Faquir, Nahid
    Collas, Valerie
    Bosmans, Bart
    Verhegghe, Benedict
    Ren, Claire
    Geleinse, Marcel
    Schultz, Carl
    van Mieghem, Nicolas
    De Beule, Matthieu
    Mortier, Peter
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (05) : 508 - 512
  • [44] PATIENT-SPECIFIC COMPUTER SIMULATION TO PREDICT LONG-TERM OUTCOMES AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Dowling, Cameron
    Firoozi, Sami
    Brecker, Stephen J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1713 - 1713
  • [45] Simulation of Transcatheter Aortic Valve Replacement and Assessment of Regurgitation in in-vitro Pulsatile Model With Patient-specific Anatomy
    Tanaka, Yutaka
    Aoyama, Yusuke
    Obama, Kazuto
    Sasuga, Saeko
    Takahashi, Azuma
    Umezu, Mitsuo
    Saito, Shigeru
    Iwasaki, Kiyotaka
    CIRCULATION, 2016, 134
  • [46] Patient-specific computer simulation to predict long-term outcomes after transcatheter aortic valve replacement
    Dowling, Cameron
    Gooley, Robert
    McCormick, Liam
    Firoozi, Sami
    Brecker, Stephen J.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2022, 16 (03) : 254 - 261
  • [47] First-in-man assessment of a dedicated guidewire for transcatheter aortic valve implantation
    Roy, David A.
    Laborde, Jean-Claude
    Sharma, Rajan
    Jahangiri, Marjan
    Brecker, Stephen J. D.
    EUROINTERVENTION, 2013, 8 (09) : 1019 - 1025
  • [48] Transcatheter Mitral Valve Implantation in a Patient With an Aortic Mechanical Valve
    van Gils, Lennart
    Olivares, Ramon Rodriguez
    Ren, Ben
    Geleijnse, Marcel L.
    Kappetein, Arie-Pieter
    De Jaegere, Peter P. T.
    Van Mieghem, Nicolas M.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04) : E31 - E33
  • [49] Preoperative computed tomography-imaging with patient-specific computer simulation in transcatheter aortic valve implantation: Design and rationale of the GUIDE-TAVI trial
    Hegeman, Romy R. M. J. J.
    van Ginkel, Dirk-Jan
    Laengle, Severin
    Timmers, Leo
    Rensing, Benno J. W. M.
    de Kroon, Thomas L.
    Sonker, Uday
    Kelder, Johannes C.
    Mach, Markus
    Andreas, Martin
    Swaans, Martin J.
    ten Berg, Jurrien M.
    Klein, Patrick
    AMERICAN HEART JOURNAL, 2024, 269 : 158 - 166
  • [50] Optimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation
    Rocatello, Giorgia
    De Santis, Gianluca
    De Bock, Sander
    De Beule, Matthieu
    Segers, Patrick
    Mortier, Peter
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2019, 10 (03) : 456 - 468