Patient-specific simulation of guidewire deformation during transcatheter aortic valve implantation

被引:6
|
作者
Vy, Phuoc [1 ,2 ,3 ,4 ]
Auffret, Vincent [3 ,4 ,5 ]
Castro, Miguel [3 ,4 ]
Badel, Pierre [2 ]
Rochette, Michel [1 ]
Haigron, Pascal [3 ,4 ]
Avril, Stephane [2 ]
机构
[1] ANSYS France, F-69100 Villeurbanne, France
[2] Ecole Natl Super Mines, INSERM, SAINBIOSE, CIS,EMSE,U1059, F-42023 St Etienne, France
[3] INSERM, U1099, F-35000 Rennes, France
[4] Univ Rennes, LTSI, Campus Beaulieu Bat 22, F-35000 Rennes, France
[5] CHU Rennes, Serv Cardiol & Malad Vasc, F-35000 Rennes, France
关键词
CATHETER NAVIGATION; REPLACEMENT; STENOSIS; MANAGEMENT;
D O I
10.1002/cnm.2974
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcatheter aortic valve implantation is a recent mini-invasive procedure to implant an aortic valve prosthesis. Prosthesis positioning in transcatheter aortic valve implantation appears as an important aspect for the success of the intervention. Accordingly, we developed a patient-specific finite element framework to predict the insertion of the stiff guidewire, used to position the aortic valve. We simulated the guidewire insertion for 2 patients based on their pre-operative CT scans. The model was designed to primarily predict the position and the angle of the guidewires in the aortic valve, and the results were successfully compared with intraoperative images. The present paper describes extensively the numerical model, which was solved by using the ANSYS software with an implicit resolution scheme, as well as the stabilization techniques which were used to overcome numerical instabilities. We performed sensitivity analysis on the properties of the guidewire (curvature angle, curvature radius, and stiffness) and the conditions of insertion (insertion force and orientation). We also explored the influence of the model parameters. The accuracy of the model was quantitatively evaluated as the distance and the angle difference between the simulated guidewires and the intraoperative ones. A good agreement was obtained between the model predictions and intraoperative views available for 2 patient cases. In conclusion, we showed that the shape of the guidewire in the aortic valve was mainly determined by the geometry of the patient's aorta and by the conditions of insertion (insertion force and orientation).
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Evaluating the Impacts of Procedural and Patient-Specific Factors on the Outcomes of Transcatheter Aortic Valve Implantation (TAVI)
    Kurmanaliyev, Abilkhair
    Braukyliene, Rima
    Aldujeli, Ali
    Zhumagaliyev, Rassul
    Aitaliyev, Serik
    Unikas, Ramunas
    MEDICINA-LITHUANIA, 2025, 61 (01):
  • [22] Coronary obstruction analysis in transcatheter aortic valve implantation through patient-specific computational modelling
    Fan, Jiaqi
    Chen, Jun
    Wang, Lihan
    Hu, Po
    Jiang, Jubo
    Lin, Xinping
    Rocatello, Giorgia
    De Beule, Matthieu
    Tie, Yi
    Wang, Yifei
    Cheng, Sihang
    Liu, Xianbao
    Wang, Jian'an
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [23] Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis
    Masuda, Takanori
    Nakaura, Takeshi
    Higaki, Toru
    Funama, Yoshinori
    Matsumoto, Yoriaki
    Sato, Tomoyasu
    Okimoto, Tomokazu
    Arao, Keiko
    Imaizumi, Hiromasa
    Arao, Shinichi
    Ono, Atsushi
    Hiratsuka, Junichi
    Awai, Kazuo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (05) : 759 - 762
  • [24] Patient-Specific Computer Simulation to Optimize Transcatheter Heart Valve Sizing and Positioning in Bicuspid Aortic Valve
    Dowling, Cameron
    Gooley, Robert
    McCormick, Liam
    Brecker, Stephen J.
    Firoozi, Sami
    Bapat, Vinayak N.
    Kodali, Susheel K.
    Khalique, Omar K.
    Brouwer, Jorn
    Swaans, Martin J.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (06): : 621 - 630
  • [25] Left Ventricular Guidewire Pacing for Transcatheter Aortic Valve Implantation
    Guerios, Enio E.
    Wenaweser, Peter
    Meier, Bernhard
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (07) : E919 - E921
  • [26] Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage
    Bianchi, Matteo
    Marom, Gil
    Ghosh, Ram P.
    Rotman, Oren M.
    Parikh, Puja
    Gruberg, Luis
    Bluestein, Danny
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2019, 18 (02) : 435 - 451
  • [27] Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage
    Matteo Bianchi
    Gil Marom
    Ram P. Ghosh
    Oren M. Rotman
    Puja Parikh
    Luis Gruberg
    Danny Bluestein
    Biomechanics and Modeling in Mechanobiology, 2019, 18 : 435 - 451
  • [28] Guidewire-driven Left Ventricular Pacing During Transcatheter Aortic Valve Implantation
    Diaz de la Llera, Luis-Salvador
    Cubero Gomez, Jose Maria
    Casquero Dominguez, Sara
    Fernandez Quero, Monica
    Villa Gil-Ortega, Manuel
    Guisado Rasco, Agustin
    REVISTA ESPANOLA DE CARDIOLOGIA, 2018, 71 (10): : 869 - 871
  • [29] Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
    Basri, Adi A.
    Zuber, Mohammad
    Basri, Ernnie, I
    Zakaria, Muhammad S.
    Aziz, Ahmad F. A.
    Tamagawa, Masaaki
    Ahmad, Kamarul A.
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2020, 2020
  • [30] Patient-specific computer simulation to optimise transcatheter heart valve sizing and positioning in bicuspid aortic valve morphology
    Dowling, Cameron
    Bavo, Alessandra
    Mortier, Peter
    El Faquir, Nahid
    de Jaegere, Peter
    De Backer, Ole
    Sondergaard, Lars
    Ruile, Philipp
    Mylotte, Darren
    McConkey, Hannah
    Rajani, Ronak
    Laborde, Jean-ClauDe
    Brecker, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B167 - B167