Patient-specific simulation of guidewire deformation during transcatheter aortic valve implantation

被引:6
|
作者
Vy, Phuoc [1 ,2 ,3 ,4 ]
Auffret, Vincent [3 ,4 ,5 ]
Castro, Miguel [3 ,4 ]
Badel, Pierre [2 ]
Rochette, Michel [1 ]
Haigron, Pascal [3 ,4 ]
Avril, Stephane [2 ]
机构
[1] ANSYS France, F-69100 Villeurbanne, France
[2] Ecole Natl Super Mines, INSERM, SAINBIOSE, CIS,EMSE,U1059, F-42023 St Etienne, France
[3] INSERM, U1099, F-35000 Rennes, France
[4] Univ Rennes, LTSI, Campus Beaulieu Bat 22, F-35000 Rennes, France
[5] CHU Rennes, Serv Cardiol & Malad Vasc, F-35000 Rennes, France
关键词
CATHETER NAVIGATION; REPLACEMENT; STENOSIS; MANAGEMENT;
D O I
10.1002/cnm.2974
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcatheter aortic valve implantation is a recent mini-invasive procedure to implant an aortic valve prosthesis. Prosthesis positioning in transcatheter aortic valve implantation appears as an important aspect for the success of the intervention. Accordingly, we developed a patient-specific finite element framework to predict the insertion of the stiff guidewire, used to position the aortic valve. We simulated the guidewire insertion for 2 patients based on their pre-operative CT scans. The model was designed to primarily predict the position and the angle of the guidewires in the aortic valve, and the results were successfully compared with intraoperative images. The present paper describes extensively the numerical model, which was solved by using the ANSYS software with an implicit resolution scheme, as well as the stabilization techniques which were used to overcome numerical instabilities. We performed sensitivity analysis on the properties of the guidewire (curvature angle, curvature radius, and stiffness) and the conditions of insertion (insertion force and orientation). We also explored the influence of the model parameters. The accuracy of the model was quantitatively evaluated as the distance and the angle difference between the simulated guidewires and the intraoperative ones. A good agreement was obtained between the model predictions and intraoperative views available for 2 patient cases. In conclusion, we showed that the shape of the guidewire in the aortic valve was mainly determined by the geometry of the patient's aorta and by the conditions of insertion (insertion force and orientation).
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Simulation of Transcatheter Aortic Valve Replacement in patient-specific aortic roots: effect of crimping and positioning on device performance
    Bianchi, Matteo
    Ghosh, Ram P.
    Marom, Gil
    Slepian, Marvin J.
    Bluestein, Danny
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 282 - 285
  • [32] Transfemoral transcatheter aortic valve implantation in the presence of a mechanical mitral valve prosthesis using a dedicated TAVI guidewire: utility of a patient-specific three-dimensional heart model
    Fujita T.
    Saito N.
    Minakata K.
    Imai M.
    Yamazaki K.
    Kimura T.
    Cardiovascular Intervention and Therapeutics, 2017, 32 (3) : 308 - 311
  • [33] Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment
    Wang, Qian
    Sirois, Eric
    Sun, Wei
    JOURNAL OF BIOMECHANICS, 2012, 45 (11) : 1965 - 1971
  • [34] PREDICTIVE EVALUATION OF PATIENT-SPECIFIC PERFORMANCE OF A TRANSCATHETER AORTIC VALVE REPLACEMENT
    Govindarajan, Vijay
    Kolanjiyil, Arun V.
    Johnson, Nils
    Kim, Hyunggun
    Chandran, Krishnan
    McPherson, David
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1738 - 1738
  • [35] Transcatheter Aortic Valve Implantation in a Patient with Unicuspid Aortic Valve
    Nascimbene, Angelo
    Loyalka, Pranav
    Gregoric, Igor D.
    Bellera, Ricardo
    Malahfji, Maan
    Petrovic, Marija
    Kar, Biswajit
    TEXAS HEART INSTITUTE JOURNAL, 2017, 44 (02): : 127 - 130
  • [36] Coronary access following ACURATE neo implantation for transcatheter aortic valve-in-valve implantation: Ex vivo analysis in patient-specific anatomies
    Khokhar, Arif A.
    Ponticelli, Francesco
    Zlahoda-Huzior, Adriana
    Chandra, Kailash
    Ruggiero, Rossella
    Toselli, Marco
    Gallo, Francesco
    Cereda, Alberto
    Sticchi, Alessandro
    Laricchia, Alessandra
    Regazzoli, Damiano
    Mangieri, Antonio
    Reimers, Bernhard
    Biscaglia, Simone
    Tumscitz, Carlo
    Campo, Gianluca
    Mikhail, Ghada W.
    Kim, Won-Keun
    Colombo, Antonio
    Dudek, Dariusz
    Giannini, Francesco
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [37] Patient-specific Computer Simulation: An Emerging Technology for Guiding the Transcatheter Treatment of Patients with Bicuspid Aortic Valve
    Dowling, Cameron
    Gooley, Robert
    Mccormick, Liam
    Firoozi, Sami
    Brecker, Stephen J.
    INTERVENTIONAL CARDIOLOGY-REVIEWS RESEARCH RESOURCES, 2021, 16
  • [38] Correction to: Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage
    Matteo Bianchi
    Gil Marom
    Ram P. Ghosh
    Oren M. Rotman
    Puja Parikh
    Luis Gruberg
    Danny Bluestein
    Biomechanics and Modeling in Mechanobiology, 2020, 19 : 779 - 779
  • [39] PATIENT-SPECIFIC 4D DIGITAL CLONING SIMULATION PREDICTS TRANSCATHETER AORTIC VALVE REPLACEMENT
    Amin, Ali Hama
    Mills, James
    Alkhouli, Mohamad
    Raybuck, Bryan
    Wei, Lawrence
    Badhwar, Vinay
    Sengupta, Partho P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1960 - 1960
  • [40] Patient-Specific Computer Simulation to Predict the Development of Conduction Disturbance Following Transcatheter Aortic Valve Replacement
    Dowling, Cameron
    Gooley, Robert
    McCormick, Liam
    Rashid, Hashrul
    Dargan, James
    Firoozi, Sami
    Brecker, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B79 - B79