Patient-specific simulation of guidewire deformation during transcatheter aortic valve implantation

被引:6
|
作者
Vy, Phuoc [1 ,2 ,3 ,4 ]
Auffret, Vincent [3 ,4 ,5 ]
Castro, Miguel [3 ,4 ]
Badel, Pierre [2 ]
Rochette, Michel [1 ]
Haigron, Pascal [3 ,4 ]
Avril, Stephane [2 ]
机构
[1] ANSYS France, F-69100 Villeurbanne, France
[2] Ecole Natl Super Mines, INSERM, SAINBIOSE, CIS,EMSE,U1059, F-42023 St Etienne, France
[3] INSERM, U1099, F-35000 Rennes, France
[4] Univ Rennes, LTSI, Campus Beaulieu Bat 22, F-35000 Rennes, France
[5] CHU Rennes, Serv Cardiol & Malad Vasc, F-35000 Rennes, France
关键词
CATHETER NAVIGATION; REPLACEMENT; STENOSIS; MANAGEMENT;
D O I
10.1002/cnm.2974
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcatheter aortic valve implantation is a recent mini-invasive procedure to implant an aortic valve prosthesis. Prosthesis positioning in transcatheter aortic valve implantation appears as an important aspect for the success of the intervention. Accordingly, we developed a patient-specific finite element framework to predict the insertion of the stiff guidewire, used to position the aortic valve. We simulated the guidewire insertion for 2 patients based on their pre-operative CT scans. The model was designed to primarily predict the position and the angle of the guidewires in the aortic valve, and the results were successfully compared with intraoperative images. The present paper describes extensively the numerical model, which was solved by using the ANSYS software with an implicit resolution scheme, as well as the stabilization techniques which were used to overcome numerical instabilities. We performed sensitivity analysis on the properties of the guidewire (curvature angle, curvature radius, and stiffness) and the conditions of insertion (insertion force and orientation). We also explored the influence of the model parameters. The accuracy of the model was quantitatively evaluated as the distance and the angle difference between the simulated guidewires and the intraoperative ones. A good agreement was obtained between the model predictions and intraoperative views available for 2 patient cases. In conclusion, we showed that the shape of the guidewire in the aortic valve was mainly determined by the geometry of the patient's aorta and by the conditions of insertion (insertion force and orientation).
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach
    Auricchio, F.
    Conti, M.
    Morganti, S.
    Reali, A.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2014, 17 (12) : 1347 - 1357
  • [2] Study of the Behavior of Different Guidewire Shapes in a Patient-specific Numerical Model for Transcatheter Aortic Valve Implantation
    Phuoc Vy
    Auffret, Vincent
    Castro, Miguel
    Badel, Pierre
    Rochette, Michel
    Haigron, Pascal
    Avril, Stephane
    Le Breton, Herve
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [3] Patient-specific simulations of transcatheter aortic valve stent implantation
    Capelli, C.
    Bosi, G. M.
    Cerri, E.
    Nordmeyer, J.
    Odenwald, T.
    Bonhoeffer, P.
    Migliavacca, F.
    Taylor, A. M.
    Schievano, S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (02) : 183 - 192
  • [4] Review of patient-specific simulations of transcatheter aortic valve implantation
    P. Vy
    V. Auffret
    P. Badel
    M. Rochette
    H. Le Breton
    P. Haigron
    S. Avril
    International Journal of Advances in Engineering Sciences and Applied Mathematics, 2016, 8 (1) : 2 - 24
  • [5] Patient-specific simulations of transcatheter aortic valve stent implantation
    C. Capelli
    G. M. Bosi
    E. Cerri
    J. Nordmeyer
    T. Odenwald
    P. Bonhoeffer
    F. Migliavacca
    A. M. Taylor
    S. Schievano
    Medical & Biological Engineering & Computing, 2012, 50 : 183 - 192
  • [6] Review of patient-specific simulations of transcatheter aortic valve implantation
    Vy, P.
    Auffret, V.
    Badel, P.
    Rochette, M.
    Le Breton, H.
    Haigron, P.
    Avril, S.
    INTERNATIONAL JOURNAL OF ADVANCES IN ENGINEERING SCIENCES AND APPLIED MATHEMATICS, 2016, 8 (01) : 2 - 24
  • [7] Patient-Specific Computational Modeling of Transcatheter Aortic Valve Implantation
    Ge, Liang
    Azadani, Ali
    Chitsaz, Sam
    Mookhoek, Aart
    Wisneski, Andrew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B265 - B265
  • [8] PATIENT-SPECIFIC COMPUTATIONAL SIMULATIONS OF TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI)
    Bosi, Giorgia M.
    Capelli, Claudio
    Chung, Robin
    Mullen, Michael
    Taylor, Andrew M.
    Schievano, Silvia
    ASME 2013 CONFERENCE ON FRONTIERS IN MEDICAL DEVICES: APPLICATIONS OF COMPUTER MODELING AND SIMULATION, 2013,
  • [9] A patient-specific mass-spring model for biomechanical simulation of aortic root tissue during transcatheter aortic valve implantation
    Cristoforetti, Alessandro
    Mase, Michela
    Bonmassari, Roberto
    Dallago, Michele
    Nollo, Giandomenico
    Ravelli, Flavia
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (08):
  • [10] Fluid Simulation of a Transcatheter Aortic Valve Deployment into a Patient-Specific Aortic Root
    Sirois E.
    Wang Q.
    Sun W.
    Cardiovascular Engineering and Technology, 2011, 2 (3) : 186 - 195