Smartphone-based inertial sensors technology - Validation of a new application to measure spatiotemporal gait metrics

被引:11
|
作者
Shema-Shiratzky, Shirley [1 ]
Beer, Yiftah [2 ]
Mor, Amit [1 ]
Elbaz, Avi [1 ]
机构
[1] AposTherapy Res Grp, Herzliyya, Israel
[2] Assaf Harofeh Med Ctr, Dept Orthopaed Surg, Zerifin, Israel
关键词
Gait; Smartphone; Concurrent validity; Musculoskeletal; HIP OSTEOARTHRITIS; RELIABILITY; VALIDITY;
D O I
10.1016/j.gaitpost.2022.01.024
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Smartphones are increasingly recognized as the future technology for clinical gait assessment. Research Question: To determine the concurrent validity of gait parameters obtained using the smartphone technology and application in a group of patients with musculoskeletal pathologies. Methods: Patients with knee, lower back, hip, or ankle pain were included in the study (n = 72). Spatiotemporal outcomes were derived from the walkway and the smartphone simultaneously. Pearson's correlations and limits of agreement (LoA) determined the association between the two methods. Results: Cadence and gait cycle time showed excellent correlation and agreement between the smartphone and the walkway (cadence: r = 0.997, LoA=1.4%, gait cycle time: r = 0.996, LoA = 1.6%). Gait speed, double-limb support and left and right step length demonstrated strong correlations and moderate agreement between methods (gait speed: r = 0.914, LoA=15.4%, left step length: r = 0.842, LoA = 17.0%, right step length: r = 0.800, LoA=16.4%). The left and right measures of single-limb support and stance percent showed a consistent 4% bias across instruments, yielding moderate correlation and very good agreement between the smartphone and the walkway (r = 0.532, LoA = 9% and r = 0.460, LoA=9.8% for left and right single-limb support; r = 0.463, LoA = 5.1% and r = 0.533, LoA = 4.4% for left and right stance). Significance: The examined application appears to be a valid tool for gait analysis, providing clinically significant metrics for the assessment of patients with musculoskeletal pathologies. However, additional studies should examine the technology amongst patients with severe gait abnormalities.
引用
收藏
页码:102 / 106
页数:5
相关论文
共 47 条
  • [41] Validation of the angular measurements of a new inertial-measurement-unit based rehabilitation system: comparison with state-of-the-art gait analysis
    Leardini, Alberto
    Lullini, Giada
    Giannini, Sandro
    Berti, Lisa
    Ortolani, Maurizio
    Caravaggi, Paolo
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [42] Validation of the angular measurements of a new inertial-measurement-unit based rehabilitation system: comparison with state-of-the-art gait analysis
    Alberto Leardini
    Giada Lullini
    Sandro Giannini
    Lisa Berti
    Maurizio Ortolani
    Paolo Caravaggi
    Journal of NeuroEngineering and Rehabilitation, 11
  • [43] Polysilicon packaging and a new anchoring technology for thick SOI MEMS -: Dynamic response model and application to over-damped inertial sensors
    Diem, B
    Barbé, JC
    de Crécy, F
    Giroud, S
    Renaud, D
    Grange, H
    Hammond, J
    Vandemeer, J
    Roop, R
    Gogoi, B
    TRANSDUCERS '05, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2005, : 527 - 530
  • [44] Hidden Markov Model-Based Strategy for Gait Segmentation using Inertial Sensors: Application to Elderly, Hemiparetic Patients and Huntington's Disease Patients
    Mannini, Andrea
    Trojaniello, Diana
    Della Croce, Ugo
    Sabatini, Angelo M.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5179 - 5182
  • [45] Cardiac output monitoring: A comparative prospective observational study of the conventional cardiac output monitor Vigileo (TM) and the new smartphone-based application Capstesia (TM)
    Shah, Shagun Bhatia
    Bhargava, Ajay Kumar
    Hariharan, Uma
    Vishvakarma, Gayatri
    Jain, Chamound Rai
    Kansal, Anamica
    INDIAN JOURNAL OF ANAESTHESIA, 2018, 62 (08) : 584 - 591
  • [46] Capability Beliefs Regarding Evidence-Based Practice are Associated with Application of EBP and Research Use: Validation of a New Measure
    Wallin, Lars
    Bostrom, Anne-Marie
    Gustavsson, J. Petter
    WORLDVIEWS ON EVIDENCE-BASED NURSING, 2012, 9 (03) : 139 - 148
  • [47] Accelerometry-Based Gait Analysis and Its Application to Parkinson's Disease Assessment-Part 2: A New Measure for Quantifying Walking Behavior
    Yoneyama, Mitsuru
    Kurihara, Yosuke
    Watanabe, Kajiro
    Mitoma, Hiroshi
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2013, 21 (06) : 999 - 1005