A portal image based quality assurance program using a commercial portal dosimetry software

被引:0
|
作者
Guerrero, M. [1 ]
Patel, I. [1 ]
机构
[1] Dept Vet Affairs Med Ctr, Washington, DC USA
关键词
D O I
10.1118/1.2760375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: There is an increasing trend in Radiation Oncology Departments to replace film as a tool for localization hence Medical Physicists increasingly find themselves without access to a film processor. Films are typically used for standard routine quality assurance (QA) of linear accelerators and IMRT commissioning and verifications. The purpose of this work is to develop a QA program using a commercial electronic portal imager (EPID) and commercial portal dosimetry software available on Varian Linear Accelerators. Method and Materials: Using Varian aS500 Portal Imager with the Portal Dosimetry Calculation (PDC) from Eclipse (commissioned according to manufacturer's recommendations), we perform a series of measurements associated with Linac QA (light‐field coincidence, flatness and symmetry, off‐axis ratios, etc), IMRT verifications and static and dynamic MLC QA. For light‐filed coincidence we use the gradicule to “mark” the edges of the light field. For flatness and symmetry we determine a “baseline” using a phantom measurement at 10cm depth and establishing a correspondence with the Portal Imager measurement. Similar baselines are established for off‐axis ratios and other measurements. Results: We present the results of our QA measurements; analyze their level of difficulty and convenience as compared with the use of film. The QA measurements performed with the portal imager are consistent with the results from our film measurements. The IMRT verifications performed with the EPID are also consistent with the ones performed with our commercial two‐dimensional diode array. We find that after we became familiar with the use of the Portal Imager and the software, the QA measurements with the portal imager are adequate and in many cases more convenient than the use of film. Conclusion: An appropriate Linac and IMRT QA program can be developed using the Varian aS500 EPID in combination with the Eclipse Portal Dosimetry Calculation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2337 / 2337
页数:1
相关论文
共 50 条
  • [31] IMPLEMENTATION OF PORTAL DOSIMETRY FOR DAILY QUALITY ASSURANCE, IMRT VERIFICATION AND DEFINITION OF ACTION LEVELS.
    Menhel, J.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S203 - S203
  • [32] Verification of multi-leaf collimator position accuracy using a commercial EPID and vendor supplied portal dosimetry software
    Taylor, M.
    Lambert, M.
    Harris, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2505 - 2505
  • [33] Quality Assurance of Multiple Brain Metastases with a Single-Isocenter Plan using Portal Dosimetry and Independent Dose Calculation
    Tanabe, M.
    Wakai, N.
    Murakami, J.
    Ikeguchi, T.
    Kitamoto, M.
    Nakano, T.
    Yoshimine, T.
    Tamamoto, T.
    Hasegawa, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E561 - E562
  • [34] Prediction of portal dosimetry quality assurance results using log files-derived errors and machine learning techniques
    Lew, Kah Seng
    Chua, Clifford Ghee Ann
    Koh, Calvin Wei Yang
    Lee, James Cheow Lei
    Park, Sung Yong
    Tan, Hong Qi
    FRONTIERS IN ONCOLOGY, 2023, 12
  • [35] LINAC Quality Assurance and Calibration Using Electronic Portal Imaging Device
    Ramirez, H.
    Yan, D.
    Zhang, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [36] EVALUATION OF PORTAL IMAGE QUALITY USING DEDICATED PHANTOM
    Blasiak, B.
    Litoborski, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S550 - S550
  • [37] Simple Suggestion for Dosimetry of an Elekta iViewGT™ Electronic Portal Imaging Device (EPID) with commercial Software modules
    Liebich, J.
    Licher, J.
    Scherf, C.
    Koch, N.
    Kara, E.
    Roedel, C.
    Ramm, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 107 - 107
  • [38] EPID Dosimetry Comparisons and Corrections: Portal Image Prediction Vs. Portal Dose Conversion
    Bailey, D.
    Kumaraswamy, L.
    Bakhtiari, M.
    Podgorsak, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [39] Use of Portal Dosimetry with EPID for Quality Control of RapidArc
    Goncalves, V.
    Vieira, A.
    da Cruz, J.
    Sakuraba, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [40] Modeling an ASi portal imager response using a commercial treatment planning software
    Khan, R.
    Ostapiak, O.
    Szabo, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2469 - 2469