The Accuracy of Wrist Skin Temperature in Detecting Ovulation Compared to Basal Body Temperature: Prospective Comparative Diagnostic Accuracy Study

被引:31
|
作者
Zhu, Tracy Y. [1 ]
Rothenbuhler, Martina [2 ]
Hamvas, Gyorgyi [1 ]
Hofmann, Anja [1 ]
Welter, JoEllen [1 ]
Kahr, Maike [1 ]
Kimmich, Nina [3 ]
Shilaih, Mohaned [2 ]
Leeners, Brigitte [1 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Reprod Endocrinol, Ramistr 100, CH-8091 Zurich, Switzerland
[2] Ava AG, Zurich, Switzerland
[3] Univ Hosp Zurich, Dept Obstet, Zurich, Switzerland
[4] Univ Zurich, Zurich, Switzerland
关键词
ovulation; basal body temperature; BBT; oral temperature; wrist skin temperature; diagnostic accuracy; thermometer; fertility; menstruation; wearable; sensor; mobile phone; CIRCADIAN-RHYTHM; PREDICTION; INDEX;
D O I
10.2196/20710
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: As a daily point measurement, basal body temperature (BBT) might not be able to capture the temperature shift in the menstrual cycle because a single temperature measurement is present on the sliding scale of the circadian rhythm. Wrist skin temperature measured continuously during sleep has the potential to overcome this limitation. Objective: This study compares the diagnostic accuracy of these two temperatures for detecting ovulation and to investigate the correlation and agreement between these two temperatures in describing thermal changes in menstrual cycles. Methods: This prospective study included 193 cycles (170 ovulatory and 23 anovulatory) collected from 57 healthy women. Participants wore a wearable device (Ava Fertility Tracker bracelet 2.0) that continuously measured the wrist skin temperature during sleep. Daily BBT was measured orally and immediately upon waking up using a computerized fertility tracker with a digital thermometer (Lady-Comp). An at-home luteinizing hormone test was used as the reference standard for ovulation. The diagnostic accuracy of using at least one temperature shift detected by the two temperatures in detecting ovulation was evaluated. For ovulatory cycles, repeated measures correlation was used to examine the correlation between the two temperatures, and mixed effect models were used to determine the agreement between the two temperature curves at different menstrual phases. Results: Wrist skin temperature was more sensitive than BBT (sensitivity 0.62 vs 0.23; P<.001) and had a higher true-positive rate (54.9% vs 20.2%) for detecting ovulation; however, it also had a higher false-positive rate (8.8% vs 3.6%), resulting in lower specificity (0.26 vs 0.70; P=.002). The probability that ovulation occurred when at least one temperature shift was detected was 86.2% for wrist skin temperature and 84.8% for BBT. Both temperatures had low negative predictive values (8.8% for wrist skin temperature and 10.9% for BBT). Significant positive correlation between the two temperatures was only found in the follicular phase (rmcorr correlation coefficient=0.294; P=.001). Both temperatures increased during the postovulatory phase with a greater increase in the wrist skin temperature (range of increase: 0.50 degrees C vs 0.20 degrees C). During the menstrual phase, the wrist skin temperature exhibited a greater and more rapid decrease (from 36.13 degrees C to 35.80 degrees C) than BBT (from 36.31 degrees C to 36.27 degrees C). During the preovulatory phase, there were minimal changes in both temperatures and small variations in the estimated daily difference between the two temperatures, indicating an agreement between the two curves. Conclusions: For women interested in maximizing the chances of pregnancy, wrist skin temperature continuously measured during sleep is more sensitive than BBT for detecting ovulation. The difference in the diagnostic accuracy of these methods was likely attributed to the greater temperature increase in the postovulatory phase and greater temperature decrease during the menstrual phase for the wrist skin temperatures.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Accuracy of recorded body temperature of critically ill patients related to measurement site: a prospective observational study
    Nonose, Y.
    Sato, Y.
    Kabayama, H.
    Arisawa, A.
    Onodera, M.
    Imanaka, H.
    Nishimura, M.
    ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (05) : 820 - 824
  • [12] Revisiting the role of serum progesterone as a test of ovulation in eumenorrheic subfertile women: a prospective diagnostic accuracy study
    Chinta, Parimala
    Rebekah, Grace
    Kunjummen, Aleyamma T.
    Kamath, Mohan S.
    FERTILITY AND STERILITY, 2020, 114 (06) : 1315 - 1321
  • [13] A Comparative Study on Temperature Accuracy between Tympanic, Rectal, and Axillary Sites
    Jahanpour, F.
    Azodi, P.
    Zare, N.
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2008, 33 (01) : 49 - 53
  • [14] CLINICAL UTILITY AND DIAGNOSTIC ACCURACY OF PHOSPHATIDYLETHANOL FOR DETECTING AND DIFFERENTIATING METALD FROM MASLD: A PROSPECTIVE STUDY
    Tavaglione, Federica
    Amangurbanova, Maral
    Yang, Alexander
    Tincopa, Monica
    Ajmera, Veeral
    Richards, Lisa
    Butcher, Christian
    Hernandez, Christie
    Madamba, Egbert
    Singh, Seema
    Bettencourt, Ricki
    Sirlin, Claude
    Loomba, Rohit
    HEPATOLOGY, 2024, 80 : S594 - S595
  • [15] Diagnostic Accuracy of Five Different Classification Systems for Thyroid Nodules A Prospective, Comparative Study
    Orhan Soylemez, Umut Percem
    Gunduz, Nesrin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (05) : 1125 - 1136
  • [16] Accuracy of Nasopharyngeal Temperature in Comparison to Oesophageal Temperature for Core Body Temperature Measurement: A Cross-sectional Observational Study
    Pooja, M. N.
    Majigoudar, Sagar S.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, -17 (12) : UC1 - UC4
  • [17] Dual-Energy CT for Suspected Radiographically Negative Wrist Fractures: A Prospective Diagnostic Test Accuracy Study
    Mueller, Felix C.
    Gosvig, Kasper K.
    Borgesen, Henrik
    Gade, Jesper S.
    Brejnebol, Mathias
    Rodell, Anders
    Nemery, Michel
    Boesen, Mikael
    RADIOLOGY, 2020, 296 (03) : 596 - 602
  • [18] Accuracy of non-invasive body temperature measurement methods in critically ill patients: a prospective, bicentric, observational study
    Cutuli, Salvatore L.
    Osawa, Eduardo A.
    Eyeington, Christopher T.
    Proimos, Helena
    Canet, Emmanuel
    Young, Helen
    Peck, Leah
    Eastwood, Glenn M.
    Glassford, Neil J.
    Bailey, Michael
    Bellomo, Rinaldo
    CRITICAL CARE AND RESUSCITATION, 2021, 23 (03) : 346 - 353
  • [19] A retrospective biopsy study of the clinical diagnostic accuracy of common skin diseases by different specialties compared with dermatology
    Sellheyer, K
    Bergfeld, WF
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2005, 52 (05) : 823 - 830
  • [20] Diagnostic accuracy of tactile imaging in selecting patients with palpable breast abnormalities: a prospective comparative study
    Tasoulis, Marios-Konstantinos
    Zacharioudakis, Konstantinos E.
    Dimopoulos, Nikitas G.
    Hadjiminas, Dimitri J.
    BREAST CANCER RESEARCH AND TREATMENT, 2014, 147 (03) : 589 - 598