Accuracy of Nasopharyngeal Temperature in Comparison to Oesophageal Temperature for Core Body Temperature Measurement: A Cross-sectional Observational Study

被引:0
|
作者
Pooja, M. N. [1 ]
Majigoudar, Sagar S. [2 ,3 ]
机构
[1] JJM Med Coll, Dept Anaesthesia, Davangere, Karnataka, India
[2] SS Inst Med Sci & Res Inst, Dept Anaesthesia, Davangere, Karnataka, India
[3] 2849 3 E Main,SS Layout B Block, Davangere 577005, Karnataka, India
关键词
Anaesthesia; Hypothermia; Intraoperative; Monitoring;
D O I
10.7860/JCDR/2023/67270.18766
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Temperature monitoring intraoperatively is standard of care for almost all surgical cases and is necessary due to the important role that temperature plays in maintaining body homeostasis, anaesthetic drug metabolism, and recovery. However, invasive and user-unfriendly methods like measuring temperature in the oesophagus, tympanic membrane, or rectum have limitations. An alternative site for measuring core body temperature could be the nasopharynx, as its mucosa is supplied by branches of the internal carotid artery. Aim: To determine the accuracy of the nasopharyngeal probe in comparison to oesophageal temperature probe and to identify appropriate insertion depths for measuring core body temperature. Materials and Methods: Sixty patients scheduled for elective non-cardiac surgery under general anaesthesia lasting 60 minutes or more. A nasopharyngeal probe was inserted past the nares to a depth of 20 cm, and an oesophageal temperature probe was inserted to a depth of 40 cm past the incisors. The nasopharyngeal probe was gradually pulled out after induction, and temperatures at various depths were recorded at regular intervals. The observed depths of the nasopharyngeal probe that correlated with the oesophageal temperature were considered as the endpoints. Data was entered into Microsoft Excel and analysed using Statistical Package for Social Sciences (SPSS) version 25.0. Results: The study population consisted of 60 patients, with 31 males and 29 females, a mean age of 50 years, mean body mass index of 26 kg/m(2), American Society of Anaesthesiologists (ASA) (physical status) of 1 (n=27) and 2 (n=33). The insertion depths of 10 to 20 cm for the nasopharyngeal probe showed a mean temperature difference of +/- 0.3 degrees C compared to the reference oesophageal temperature. This difference fell within the clinically acceptable accuracy range of 0 to 0.3 degrees C (temperature mean difference +/- 1.96 SD) for both probes. Conclusion: The nasopharyngeal probe offers a minimally invasive method for measuring body temperature and is easily accessible for probe placement. However, the optimal depth of insertion past the nares has not been well established. Based on the results, which showed that the mean temperature difference between the two probes fell within the specified accuracy range when the nasopharyngeal probe was inserted to a depth range of 10 to 20 cm from the nares, it is advisable to use this depth range for core body temperature measurement in non cardiac surgeries.
引用
收藏
页码:UC1 / UC4
页数:4
相关论文
共 50 条
  • [1] The effects of measurement site and ambient temperature on body temperature values in healthy older adults: A cross-sectional comparative study
    Lu, Shu-Hua
    Dai, Yu-Tzu
    Yen, Chung-Jen
    INTERNATIONAL JOURNAL OF NURSING STUDIES, 2009, 46 (11) : 1415 - 1422
  • [2] Clinical accuracy of infrared temperature measurement devices: a comparison against non-invasive core-body temperature
    Holder, Thomas
    Hooper, Frances Sophie Woodley
    Yates, David
    Tse, Zion
    Patil, Samadhan
    Moussa, Ahmed
    Batten, Lucy
    Radhakrishnan, Vignesh
    Allison, Mark
    Hewitt, Catherine
    Keding, Ada
    Forshaw, Greg
    Jayagopal, Vijay
    CLINICAL MEDICINE, 2023, 23 (02) : 157 - 163
  • [3] Cross-sectional area of the murine aorta linearly increases with increasing core body temperature
    Crouch, A. Colleen
    Manders, Adam B.
    Cao, Amos A.
    Scheven, Ulrich M.
    Greve, Joan M.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (07) : 1121 - 1133
  • [4] Regulation of core body temperature during whole body hyperthermia by oesophageal temperature feedback
    Schuette, W.H.
    Lees, D.E.
    Bull, J.M.
    Medical and Biological Engineering and Computing, 1980, 18 (03): : 299 - 302
  • [5] Body temperature at nursery admission in a cohort of healthy newborn infants: results from an observational cross-sectional study
    Daniele Merazzi
    Ilia Bresesti
    Paolo Tagliabue
    Maria Grazia Valsecchi
    Paola De Lorenzo
    Gianluca Lista
    Italian Journal of Pediatrics, 46
  • [6] Body temperature at nursery admission in a cohort of healthy newborn infants: results from an observational cross-sectional study
    Merazzi, Daniele
    Bresesti, Ilia
    Tagliabue, Paolo
    Valsecchi, Maria Grazia
    De Lorenzo, Paola
    Lista, Gianluca
    Daniele, Irene
    Daniele, Irene
    Restelli, Rosanna
    Bollani, Lina
    Maini, Antonella
    Bellan, Cristina
    Zappella, Emanuela
    Colombo, Lorenzo
    Sorrentino, Gabriele
    Ciraci, Giovanni
    Lomazzi, Marcella
    Lombardo, Ilaria
    Ferraresi, Marilena
    Pagani, Luciana
    Bernardo, Luca
    Romani, Manuela
    Agosti, Massimo
    Martinelli, Stefano
    Miraglia, Giuseppe
    Palumbo, Emilio
    Menghi, Veronica
    Cavalli, Claudio
    Paternieri, Arianna
    Messina, Daniela
    Teani, Maddalena
    Barachetti, Roberta
    Lazzari, Franca
    ITALIAN JOURNAL OF PEDIATRICS, 2020, 46 (01)
  • [7] Measurement of horse core body temperature
    Green, AR
    Gates, SG
    Lawrence, LM
    JOURNAL OF THERMAL BIOLOGY, 2005, 30 (05) : 370 - 377
  • [8] Measurement of core temperature during postoperative rewarming; a comparison of oesophageal, bladder, and rectal temperatures
    Brauer, A
    Weyland, W
    Fritz, U
    Schuhmann, MU
    Schmidt, JH
    Braun, U
    ANAESTHESIST, 1997, 46 (08): : 683 - 688
  • [9] Accuracy of recorded body temperature of critically ill patients related to measurement site: a prospective observational study
    Nonose, Y.
    Sato, Y.
    Kabayama, H.
    Arisawa, A.
    Onodera, M.
    Imanaka, H.
    Nishimura, M.
    ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (05) : 820 - 824
  • [10] Measurement of the core temperature of the body - A methodic challenge?
    Esch, JSA
    Horn, EP
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1997, 32 (07): : 399 - 400