Accuracy of Nasopharyngeal Temperature in Comparison to Oesophageal Temperature for Core Body Temperature Measurement: A Cross-sectional Observational Study

被引:0
|
作者
Pooja, M. N. [1 ]
Majigoudar, Sagar S. [2 ,3 ]
机构
[1] JJM Med Coll, Dept Anaesthesia, Davangere, Karnataka, India
[2] SS Inst Med Sci & Res Inst, Dept Anaesthesia, Davangere, Karnataka, India
[3] 2849 3 E Main,SS Layout B Block, Davangere 577005, Karnataka, India
关键词
Anaesthesia; Hypothermia; Intraoperative; Monitoring;
D O I
10.7860/JCDR/2023/67270.18766
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Temperature monitoring intraoperatively is standard of care for almost all surgical cases and is necessary due to the important role that temperature plays in maintaining body homeostasis, anaesthetic drug metabolism, and recovery. However, invasive and user-unfriendly methods like measuring temperature in the oesophagus, tympanic membrane, or rectum have limitations. An alternative site for measuring core body temperature could be the nasopharynx, as its mucosa is supplied by branches of the internal carotid artery. Aim: To determine the accuracy of the nasopharyngeal probe in comparison to oesophageal temperature probe and to identify appropriate insertion depths for measuring core body temperature. Materials and Methods: Sixty patients scheduled for elective non-cardiac surgery under general anaesthesia lasting 60 minutes or more. A nasopharyngeal probe was inserted past the nares to a depth of 20 cm, and an oesophageal temperature probe was inserted to a depth of 40 cm past the incisors. The nasopharyngeal probe was gradually pulled out after induction, and temperatures at various depths were recorded at regular intervals. The observed depths of the nasopharyngeal probe that correlated with the oesophageal temperature were considered as the endpoints. Data was entered into Microsoft Excel and analysed using Statistical Package for Social Sciences (SPSS) version 25.0. Results: The study population consisted of 60 patients, with 31 males and 29 females, a mean age of 50 years, mean body mass index of 26 kg/m(2), American Society of Anaesthesiologists (ASA) (physical status) of 1 (n=27) and 2 (n=33). The insertion depths of 10 to 20 cm for the nasopharyngeal probe showed a mean temperature difference of +/- 0.3 degrees C compared to the reference oesophageal temperature. This difference fell within the clinically acceptable accuracy range of 0 to 0.3 degrees C (temperature mean difference +/- 1.96 SD) for both probes. Conclusion: The nasopharyngeal probe offers a minimally invasive method for measuring body temperature and is easily accessible for probe placement. However, the optimal depth of insertion past the nares has not been well established. Based on the results, which showed that the mean temperature difference between the two probes fell within the specified accuracy range when the nasopharyngeal probe was inserted to a depth range of 10 to 20 cm from the nares, it is advisable to use this depth range for core body temperature measurement in non cardiac surgeries.
引用
收藏
页码:UC1 / UC4
页数:4
相关论文
共 50 条
  • [41] CROSS-SECTIONAL TEMPERATURE DISTRIBUTION IN SODERBERG ANODES - EXPERIMENT AND MODELS
    TORKLEP, KE
    HALVORSEN, SA
    PEDERSEN, TP
    JOURNAL OF METALS, 1982, 35 (12): : A91 - A91
  • [42] Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensors
    Chunyan Li
    Pei-Ming Wu
    Zhizhen Wu
    Chong H. Ahn
    David LeDoux
    Lori A. Shutter
    Jed A. Hartings
    Raj K. Narayan
    Biomedical Microdevices, 2012, 14 : 109 - 118
  • [43] Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensors
    Li, Chunyan
    Wu, Pei-Ming
    Wu, Zhizhen
    Ahn, Chong H.
    LeDoux, David
    Shutter, Lori A.
    Hartings, Jed A.
    Narayan, Raj K.
    BIOMEDICAL MICRODEVICES, 2012, 14 (01) : 109 - 118
  • [44] Association between raised body temperature and acute mountain sickness: cross sectional study
    Maggiorini, M
    Bartsch, P
    Oelz, O
    BRITISH MEDICAL JOURNAL, 1997, 315 (7105): : 403 - 404
  • [45] Reliability of Tracheal Temperature as a Measurement of Core Body Temperature During Cardiac Surgery Using Cardiopulmonary Bypass
    Kang, Hyun-Uk
    Lee, Sou-Hyun
    Chin, Ji-Hyun
    Choi, In-Cheol
    Kim, Kyungmi
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (02)
  • [46] A study of temperature measurement with wide scope and high accuracy
    Zhang, CJ
    Wang, HJ
    Cao, PW
    Yong, Y
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 247 - 249
  • [47] Accuracy of the non-invasive Tcore™ temperature monitoring system to measure body core temperature in abdominal surgery
    Martin Soehle
    Hilmar Dehne
    Andreas Hoeft
    Sven Zenker
    Journal of Clinical Monitoring and Computing, 2020, 34 : 1361 - 1367
  • [48] Accuracy of the non-invasive Tcore™ temperature monitoring system to measure body core temperature in abdominal surgery
    Soehle, Martin
    Dehne, Hilmar
    Hoeft, Andreas
    Zenker, Sven
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (06) : 1361 - 1367
  • [49] Measurement of non-invasive rectal and ear temperature in inpatients 18 years old: A cross-sectional comparative study
    Jorgensen, Lone
    Boll, Birgitte
    Rosenkilde, Kristina Fischer
    Bruun, Niels Henrik
    Pedersen, Preben Ulrich
    Norgaard, Marianne Wetendorff
    ZEITSCHRIFT FUR EVIDENZ FORTBILDUNG UND QUALITAET IM GESUNDHEITSWESEN, 2025, 192 : 36 - 41
  • [50] ASSOCIATION BETWEEN INDOOR TEMPERATURE AND GENERAL HEALTH IN ENGLISH ADULTS: A CROSS-SECTIONAL STUDY
    Sutton-Klein, J.
    Moody, A.
    Mindell, J.
    JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2017, 71 : A64 - A64