A Comparative Study on Temperature Accuracy between Tympanic, Rectal, and Axillary Sites

被引:0
|
作者
Jahanpour, F. [1 ]
Azodi, P. [1 ]
Zare, N. [2 ]
机构
[1] Bushehr Univ Med Sci, Dept Nursing & Midwifery, Bushehr, Iran
[2] Shiraz Univ Med Sci, Dept Biostat & Epidemiol, Shiraz, Iran
关键词
Tympanic; axillaries; rectal temperature; pediatric; fever;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new method recently used for measuring the temperature is using tympanic thermometer. The aim of this study was to compare the accuracy of this method with rectal and axillary measurement in children less than 6 years old. A total of 220 pair ears, axillaries, and rectal sites were used to determine the body temperature in patients aged between 3 months to 6 years who referred to Emergency Department of Fateme Zahra Hospital affiliated to Bushehr University of Medical Sciences. Rectal temperature (RT) was considered as gold standard. Fever was defined as RT >= 38 degrees C, axillary temperature (AT) 3 37.2 degrees C and tympanic temperature (TT) >= 38 degrees C. Correlation between rectal and tympanic temperature was statistically significant. The mean difference between RT and TT was 0.3 degrees C and between RT and AT was 0.1 degrees C. When cutoff point was considered 38 degrees C for TT, the sensitivity was 46%, specificity was 97% and positive predictive value (PPV) and negative predictive value (NPV) were 92% and 72% respectively. ROC curve showed the best cutoff point for TT as 37 degrees C, which increased the sensitivity to 92% and PPV to 0.98 but decreased the specificity to 90% and NPV to 0.57. Kappa test showed a good agreement rate between RT and TT. Age had significant effects on the TT/RT relationship. If the cut off point for TT is set at 38 degrees C the sensitivity and NPV will be unacceptably low and a number of children with fever may be missed by screening with a tympanic thermometer. If the cutoff point is 37 degrees C, the sensitivity and NPV will improve and TT can be used as a safe, easy, rapid, and accurate method in pediatrics.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
  • [1] Comparative study of body temperature with rectal and tympanic methods.
    Crétel, E
    Sibaï, A
    Taupin, P
    Hausfater, P
    Piette, JC
    Cacoub, P
    REVUE DE MEDECINE INTERNE, 1999, 20 (11): : 981 - 984
  • [2] Axillary and tympanic membrane temperature recording in the preterm neonate: a comparative study
    Bailey, J
    Rose, P
    JOURNAL OF ADVANCED NURSING, 2001, 34 (04) : 465 - 474
  • [3] AXILLARY VERSUS RECTAL TEMPERATURE - COMPARATIVE-STUDY
    BUNTAIN, WL
    PREGLER, M
    OBRIEN, PC
    LYNN, HB
    JOURNAL OF THE LOUISIANA STATE MEDICAL SOCIETY, 1977, 129 (01): : 5 - 8
  • [4] Comparison of axillary, tympanic membrane and rectal temperature measurement in cats
    Smith, Victoria A.
    Lamb, Valerie
    McBrearty, Alix R.
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2015, 17 (12) : 1028 - 1034
  • [5] Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers
    Jensen, BN
    Jensen, FS
    Madsen, SN
    Lossl, K
    EUROPEAN JOURNAL OF SURGERY, 2000, 166 (11) : 848 - 851
  • [6] Comparison of rectal, tympanic membrane and axillary temperature measurement methods in dogs
    Lamb, V.
    McBrearty, A. R.
    VETERINARY RECORD, 2013, 173 (21) : 524 - +
  • [7] Comparison of axillary, tympanic and standard rectal temperature in haematologic patients; the results!
    Hollenberg, M. M. M.
    van den Ancker, W.
    Visser, O.
    Huijgens, P. C.
    BONE MARROW TRANSPLANTATION, 2013, 48 : S479 - S479
  • [8] Comparison of axillary, rectal and tympanic temperature measurements in children admitted with malaria
    Musumba, CO
    Griffiths, KL
    Ross, A
    Newton, CRJC
    JOURNAL OF TROPICAL PEDIATRICS, 2005, 51 (04) : 242 - 244
  • [9] A comparative study of rectal tympanic and axillary thermometry in febrile children under 5 years of age in Nigeria
    Abdulkadir, Mohammed Baba
    Johnson, Wahab Babatunde Rotimi
    PAEDIATRICS AND INTERNATIONAL CHILD HEALTH, 2013, 33 (03) : 165 - 169
  • [10] Accuracy of the Axillary Temperature Screening Compared to Core Rectal Temperature in Infants
    Alayed, Yazeed
    Kilani, Mohammed A.
    Hommadi, Abdullah
    Alkhalifah, Mohammed
    Alhaffar, Dalal
    Bashir, Muhammad
    GLOBAL PEDIATRIC HEALTH, 2022, 9