Time resolution for scattered and unscattered coincidences in a TOF PET scanner

被引:0
|
作者
Conti, Maurizio [1 ]
Rothfuss, Harold [1 ]
机构
[1] Siemens Healthcare, Mol Imaging, Knoxville, TN 37932 USA
关键词
OF-FLIGHT;
D O I
10.1109/NSSMIC.2009.5402003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Time resolution is a key parameter in the performance of a TOF PET scanner, and it is usually measured in the system with unscattered data and used as the width of the TOF kernel in reconstruction. In fact, the time distribution of detected coincidence events is a function of the energy of the detected photons, and trues and scatter events have different time distributions. While the reconstruction TOF kernel should match the true, unscattered data, the scatter simulation used for scatter correction should match the time distribution of the scatter data. This work, using experimental measurements and Monte Carlo simulation, confirmed that the time resolution in a PET scanner is dependent on the energy of the detected photon pair. Moreover, it was observed that trues, single and multiple scatter in general have different time distributions. The FWHM of the time distribution of trues and scatter in different configurations of phantoms and energy threshold were evaluated. The width of the time distribution for scatter was observed to be much larger than for trues, particularly because of the effect of multiple scatter, if low energy thresholds are used. On the other hand, the use of a high energy threshold (for example, 435 keV) reduces the timing FWHM of scatter and the weight of multiple scatter, and allows the use of single scatter simulation as a good approximation of the data time distribution in a realistic PET scan.
引用
收藏
页码:2629 / 2635
页数:7
相关论文
共 50 条
  • [41] Improving the Time Resolution of TOF-PET Detectors by Double-Sided Readout
    Seifert, Stefan
    Schaart, Dennis R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 3 - 11
  • [42] Sensitivity Improvement of Time-of-Flight (ToF)-PET Detector through Recovery of Compton Scattered Annihilation Photons
    Wagadarikar, Ashwin A.
    Ivan, Adrian
    Dolinsky, Sergei
    McDaniel, David L.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3178 - 3183
  • [43] Design considerations for a limited angle, dedicated breast, TOF PET scanner
    Surti, S.
    Karp, J. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11): : 2911 - 2921
  • [44] Achieving 10 ps coincidence time resolution in TOF-PET is an impossible dream
    Schaart, Dennis R.
    Ziegler, Sibylle
    Zaidi, Habib
    MEDICAL PHYSICS, 2020, 47 (07) : 2721 - 2724
  • [45] Positron Emission Tomography (PET) Imaging Reconstruction using higher order Scattered Photon Coincidences
    Sun, Hongwei
    Pistorius, Stephen
    MEDICAL PHYSICS, 2016, 43 (08) : 4935 - 4935
  • [46] Sensitivity Improvement of Time-of-Flight (ToF) PET Detector Through Recovery of Compton Scattered Annihilation Photons
    Wagadarikar, Ashwin A.
    Ivan, Adrian
    Dolinsky, Sergei
    McDaniel, David L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 121 - 125
  • [47] Investigation of image quality and NEC in a TOF-capable PET scanner
    Surti, S
    Karp, JS
    Popescu, LM
    Daube-Witherspoon, ME
    Werner, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4032 - 4037
  • [48] Simultaneous reconstruction of both true and scattered coincidences using a Generalized Scatter reconstruction algorithm in PET
    Sun, H.
    Pistorious, S.
    MEDICAL PHYSICS, 2014, 41 (08) : 8 - 8
  • [49] Using triple gamma coincidences with a pixelated semiconductor Compton-PET scanner: a simulation study
    Kolstein, M.
    Chmeissani, M.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [50] Evaluation of the HD and HD plus TOF reconstructions for Siemens' Biograph-mCT TOF PET scanner
    Cheng, Ju-Chieh
    Laforest, Richard
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4131 - 4134