Time resolution for scattered and unscattered coincidences in a TOF PET scanner

被引:0
|
作者
Conti, Maurizio [1 ]
Rothfuss, Harold [1 ]
机构
[1] Siemens Healthcare, Mol Imaging, Knoxville, TN 37932 USA
关键词
OF-FLIGHT;
D O I
10.1109/NSSMIC.2009.5402003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Time resolution is a key parameter in the performance of a TOF PET scanner, and it is usually measured in the system with unscattered data and used as the width of the TOF kernel in reconstruction. In fact, the time distribution of detected coincidence events is a function of the energy of the detected photons, and trues and scatter events have different time distributions. While the reconstruction TOF kernel should match the true, unscattered data, the scatter simulation used for scatter correction should match the time distribution of the scatter data. This work, using experimental measurements and Monte Carlo simulation, confirmed that the time resolution in a PET scanner is dependent on the energy of the detected photon pair. Moreover, it was observed that trues, single and multiple scatter in general have different time distributions. The FWHM of the time distribution of trues and scatter in different configurations of phantoms and energy threshold were evaluated. The width of the time distribution for scatter was observed to be much larger than for trues, particularly because of the effect of multiple scatter, if low energy thresholds are used. On the other hand, the use of a high energy threshold (for example, 435 keV) reduces the timing FWHM of scatter and the weight of multiple scatter, and allows the use of single scatter simulation as a good approximation of the data time distribution in a realistic PET scan.
引用
收藏
页码:2629 / 2635
页数:7
相关论文
共 50 条
  • [21] INCREMENTAL BENEFIT OF HIGH RESOLUTION PET/CT THROUGH THE LIVER USING A NEW GENERATION TOF SCANNER
    Gradinscak, D.
    Schembri, G.
    Roach, P.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 10 - 10
  • [22] Use of Scattered Coincidences for Emission-Based Estimation of Attenuation Map in PET
    Berker, Yannick
    Kiessling, Fabian
    Schulz, Volkmar
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2285 - 2287
  • [23] Convolutional neural networks in the classification of multiphoton coincidences in a J-PET scanner
    Konieczka, Pawel
    Raczynski, Lech
    Wislicki, Wojciech
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 43 - 47
  • [24] Strip-PET: a novel detector concept for the TOF-PET scanner
    Moskal, Pawel
    Bednarski, Tomasz
    Bialas, Piotr
    Ciszewska, Marta
    Czerwinski, Eryk
    Heczko, Andrzej
    Kajetanowicz, Marcin
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Konopka-Cupial, Gabriela
    Korcyl, Grzegorz
    Krzemien, Wojciech
    Lojek, Konrad
    Majewski, Jerzy
    Migdal, Wojciech
    Molenda, Marcin
    Niedzwiecki, Szymon
    Palka, Marek
    Rudy, Zbigniew
    Salabura, Piotr
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Zdebik, Jaroslaw
    Zielinski, Marcin
    NUCLEAR MEDICINE REVIEW, 2012, 15 : C68 - C69
  • [25] Timing resolution measurement for TOF PET
    Yao, Shulin
    Chen, Yingmao
    Xu, Baixuan
    Chen, Ze
    An, Shaohui
    Chen, Mu
    Tian, Jiahe
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [26] Exploring the Potential of a Cherenkov TOF PET Scanner: A Simulation Study
    Razdevsek, G.
    Pestotnik, R.
    Krizan, P.
    Korpar, S.
    Consuegra, D.
    Seljak, A.
    Studen, A.
    Dolenec, R.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (01) : 52 - 61
  • [27] Optimization of acquisition and reconstruction parameters of a TOF PET/CT scanner
    Chang, Tingting
    Clark, John
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [28] A conformal TOF-DOI Prism-PET prototype scanner for high-resolution quantitative neuroimaging
    Zeng, Xinjie
    Wang, Zipai
    Tan, Wanbin
    Petersen, Eric
    Cao, Xinjie
    LaBella, Andy
    Boccia, Anthony
    Franceschi, Dinko
    de Leon, Mony
    Chiang, Gloria Chia-Yi
    Qi, Jinyi
    Biegon, Anat
    Zhao, Wei
    Goldan, Amir H.
    MEDICAL PHYSICS, 2023, 50 (06) : 3401 - 3417
  • [29] Time and DOI Resolution Measurements of Minidetectors for a PET-TOF Prostate Probe
    Cosentino, L.
    Cusanno, F.
    De Leo, R.
    Finocchiaro, P.
    Gabrielli, A.
    Garibaldi, F.
    Giorgi, F.
    Giuliani, F.
    Gricia, M.
    Loddo, F.
    Lucentini, M.
    Meddi, F.
    Monno, E.
    Musico, P.
    Pappalardo, A.
    Perrino, R.
    Ranieri, A.
    Turisini, M.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3314 - 3316
  • [30] Time resolution deterioration with increasing crystal length in a TOF-PET system
    Gundacker, S.
    Knapitsch, A.
    Auffray, E.
    Jarron, P.
    Meyer, T.
    Lecoq, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 737 : 92 - 100