Time resolution for scattered and unscattered coincidences in a TOF PET scanner

被引:0
|
作者
Conti, Maurizio [1 ]
Rothfuss, Harold [1 ]
机构
[1] Siemens Healthcare, Mol Imaging, Knoxville, TN 37932 USA
关键词
OF-FLIGHT;
D O I
10.1109/NSSMIC.2009.5402003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Time resolution is a key parameter in the performance of a TOF PET scanner, and it is usually measured in the system with unscattered data and used as the width of the TOF kernel in reconstruction. In fact, the time distribution of detected coincidence events is a function of the energy of the detected photons, and trues and scatter events have different time distributions. While the reconstruction TOF kernel should match the true, unscattered data, the scatter simulation used for scatter correction should match the time distribution of the scatter data. This work, using experimental measurements and Monte Carlo simulation, confirmed that the time resolution in a PET scanner is dependent on the energy of the detected photon pair. Moreover, it was observed that trues, single and multiple scatter in general have different time distributions. The FWHM of the time distribution of trues and scatter in different configurations of phantoms and energy threshold were evaluated. The width of the time distribution for scatter was observed to be much larger than for trues, particularly because of the effect of multiple scatter, if low energy thresholds are used. On the other hand, the use of a high energy threshold (for example, 435 keV) reduces the timing FWHM of scatter and the weight of multiple scatter, and allows the use of single scatter simulation as a good approximation of the data time distribution in a realistic PET scan.
引用
收藏
页码:2629 / 2635
页数:7
相关论文
共 50 条
  • [31] A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences:: implementation on the ECAT EXACT HR
    Ferreira, NC
    Trébossen, R
    Lartizien, C
    Brulon, V
    Merceron, P
    Bendriem, B
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (09): : 1555 - 1571
  • [32] Value of Non-TOF Reconstruction from TOF Compressed Data for High Resolution TOF Scanner
    Panin, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S351 - S352
  • [33] Characterization the annihilation position distribution within a geometrical model associated with scattered coincidences in PET
    Sun, Hongyan
    Pistorius, Stephen
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [34] J-PET: a novel TOF-PET scanner based on plastic scintillators
    Moskal, P.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Czerwinski, E.
    Gajos, A.
    Gorgol, M.
    Jasinska, B.
    Kaminska, D.
    Kaplon, L.
    Krzemien, W.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, Sz.
    Palka, M.
    Pawlik-Niedzwiecka, M.
    Raczynski, L.
    Rudy, Z.
    Rundel, O.
    Sharma, G.
    Silarski, M.
    Slomski, A.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S76 - S76
  • [35] Performance of an Ultralow-Dose High-Resolution Pediatric TOF-PET Scanner Based on Monolithic Scintillators
    Mikhaylova, E.
    Tabacchini, V.
    Borghi, G.
    Vogel, W.
    Mollet, P.
    D'Hoe, E.
    Schaart, D.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S437 - S437
  • [36] Simulation and optimization of the Cherenkov TOF whole-body PET scanner
    Alokhina, Marharyta
    Canot, Clotilde
    Bezshyyko, Oleg
    Kadenko, Igor
    Tauzin, Gerard
    Yvon, Dominique
    Sharyy, Viatcheslav
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 378 - 381
  • [37] IMPROVEMENT OF TIME RESOLUTION IN A TOF PET SYSTEM WITH THE USE OF BAF2 CRYSTALS
    ISHII, K
    WATANUKI, S
    ORIHARA, H
    ITOH, M
    MATSUZAWA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 253 (01): : 128 - 134
  • [38] Predicting Small Lesion Detectability for a Small Animal TOF PET Scanner
    Yussefian, Nikta Zarif
    Gaudin, Emilie
    Lecomte, Roger
    Fontaine, Rejean
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (05) : 601 - 608
  • [39] Evaluation of Local PMT Triggering Electronics for a TOF-PET Scanner
    Kyba, Christopher C. M.
    Wiener, Rony I.
    Newcomer, F. M.
    Perkins, Amy E.
    Kulp, Randall R.
    Werner, Matthew E.
    Surti, Suleman
    Dressnandt, Nandor
    Van Berg, Richard
    Karp, Joel S.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3881 - +
  • [40] A method to enhance coincidence time resolution with applications for medical imaging systems (TOF/PET)
    Ermis, E. E.
    Celiktas, C.
    Pilicer, E.
    RADIATION MEASUREMENTS, 2014, 62 : 52 - 59