Improving the dynamic measurements of ADCs using the 2-ADC method

被引:2
|
作者
Cauvet, P [1 ]
机构
[1] Digital Media Philips Semicond, Test & Prod Engn Dept, F-14043 Caen 5, France
关键词
analog-to-digital converter (ADC); jitter; aperture uncertainty; signal-to-noise ratio (SNR);
D O I
10.1016/S0920-5489(00)00048-9
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Testing high-resolution analog-to-digital converters (greater than or equal to 12 bit) at high input frequencies (>5 MHz) becomes more difficult, because the disturbances of the automatic test equipment (ATE) become more significant. Although a lot of improvements have been made to modern ATEs during recent years, they are not sufficient, given the components specifications, especially the signal-to-noise ratio (SNR) parameter. This paper briefly describes the errors of the converters, which have to be tested, and those introduced by the equipment. From this description, a model has been built to simulate a new method based on the simultaneous measurement of two converters and which is intended to give an accurate estimation of the SNR, removing the correlated disturbances. The simulation results show the potential benefits of the method, and eventually, the experimental results in an industrial environment are given and discussed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [41] MEASUREMENTS OF THE OUTGASSING RATE BY A DYNAMIC METHOD
    HALAS, A
    MORAW, M
    PRASOL, H
    VIDE-SCIENCE TECHNIQUE ET APPLICATIONS, 1993, 49 (268): : 311 - 326
  • [42] A DYNAMIC METHOD FOR THE MEASUREMENTS OF PIEZOELECTRIC CONSTANTS
    BUCK, P
    REINHARDT, J
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1983, 163 (3-4): : 233 - 241
  • [44] A Self Calibration Method of a Pipeline ADC Based on Dynamic Capacitance Allotment
    Chatterjee, Shatadal
    Roy, Sounak
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2022, 30 (05) : 666 - 670
  • [45] The glass transition temperature measurements of polyethylene: determined by using molecular dynamic method
    Yang, Qing
    Chen, Xin
    He, Zhouwen
    Lan, Fengtao
    Liu, Hui
    RSC ADVANCES, 2016, 6 (15): : 12053 - 12060
  • [46] Dynamic shape and strain measurements of rotating tire using a sampling moire method
    Fujigaki, Motoharu
    Shimo, Kosuke
    Masaya, Akihiro
    Morimoto, Yoshiharu
    OPTICAL ENGINEERING, 2011, 50 (10)
  • [47] Temperature Determination in Shocked Quartz Using an Alternative Method of Dynamic Pyrometry Measurements
    Shelton, H. L.
    Opachich, Y. P.
    Mehta, H. N.
    Crum, R. S.
    Dutra, E.
    Akin, M. C.
    SHOCK COMPRESSION OF CONDENSED MATTER - 2019, 2020, 2272
  • [48] Dynamic measurements and uncertainty estimation of clinical thermometers using Monte Carlo method
    Ogorevc, Jaka
    Bojkovski, Jovan
    Pusnik, Igor
    Drnovsek, Janko
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (09)
  • [49] Dynamic method as a simple approach for wide range pH measurements using optodes
    Safavi, A.
    Banazadeh, A. R.
    ANALYTICA CHIMICA ACTA, 2007, 583 (02) : 326 - 331
  • [50] SAR plus ΔΣ ADCs with open-loop integrator using dynamic amplifier
    Matsuzawa, Akira
    Miyahara, Masaya
    IEICE ELECTRONICS EXPRESS, 2018, 15 (06):