Echocardiographic measurement of cardiac output in rats

被引:71
|
作者
Slama, M
Susic, D
Varagic, J
Ahn, J
Frohlich, ED
机构
[1] Alton Ochsner Med Fdn & Ochsner Clin, Div Res, New Orleans, LA 70121 USA
[2] Univ Picardie, Fac Med, Lab Pharmacol & Physiopathol Cardiovasc, F-80054 Amiens, France
关键词
Doppler; blood volume changes;
D O I
10.1152/ajpheart.00653.2002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The systematic evaluation of different transthoracic echocardiographic (TTE) methods to determine cardiac output (CO) and the effect of changes in intravascular volume on echocardiographically determined indexes of cardiovascular structure in the rat has not been documented. With the use of 11 Wistar rats, simultaneous echocardiographic and thermodilution measurements of CO were compared at baseline and after blood withdrawal or transfusion at 43 different levels of intravascular volume and using 10 different echocardiographic approaches. The best correlation (r = 0.93; P < 0.0001), least bias (-3 ml/min), and best precision (16 ml/min) between thermodilution and echocardiographic methods were obtained at the level of aortic annulus using pulsed Doppler. In conclusion, CO could be accurately assessed in rats using TTE and pulsed Doppler at the level of the aortic annulus. This annulus was demonstrated to remain stable, but pulmonary annulus, thoracic aorta, mitral valve, and left ventricular diameters were found to be more modifiable during volumic changes.
引用
收藏
页码:H691 / H697
页数:7
相关论文
共 50 条
  • [32] VALIDITY OF THERMAL DILUTION TECHNIQUE FOR MEASUREMENT OF CARDIAC-OUTPUT IN RATS
    KISSLING, G
    ROSS, C
    BRANDLE, M
    AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (03): : H1007 - H1013
  • [33] TRANSESOPHAGEAL ECHOCARDIOGRAPHIC MEASUREMENTS OF CARDIAC-OUTPUT IN CARDIAC SURGICAL PATIENTS
    IZZAT, MB
    REGRAGUI, IA
    WILDE, P
    ANGELINI, GD
    BRYAN, AJ
    ANNALS OF THORACIC SURGERY, 1994, 58 (05): : 1486 - 1489
  • [34] DOPPLER-ECHOCARDIOGRAPHIC ASSESSMENT OF CARDIAC-OUTPUT
    ASCAH, KJ
    STEWART, WJ
    LEVINE, RA
    WEYMAN, AE
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1985, 23 (04) : 659 - 670
  • [35] Transgastric, pulsed Doppler echocardiographic determination of cardiac output
    DescorpsDeclere, A
    Smail, N
    Vigue, B
    Duranteau, J
    Mimoz, O
    Edouard, A
    Samii, K
    INTENSIVE CARE MEDICINE, 1996, 22 (01) : 34 - 38
  • [36] MEASUREMENT OF CARDIAC OUTPUT IN MAN
    TAYLOR, SH
    PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1966, S 59 : 35 - +
  • [37] CARDIAC OUTPUT MEASUREMENT BY ECHOCARDIOGRAPHY
    KINGSLEY, B
    FLINT, G
    BELL, D
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1969, SU16 (01): : 31 - &
  • [38] MEASUREMENT OF CARDIAC-OUTPUT
    SKIDMORE, R
    WELLS, PNT
    LANCET, 1988, 2 (8615): : 854 - 854
  • [39] AN INSTRUMENT FOR THE MEASUREMENT OF CARDIAC OUTPUT
    POWERS, SR
    ROSSI, HH
    PAPPER, EM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1952, 23 (04): : 178 - 181
  • [40] MEASUREMENT OF CARDIAC-OUTPUT
    WEIL, MH
    CRITICAL CARE MEDICINE, 1977, 5 (02) : 117 - 119