Echocardiographic measurement of cardiac output in rats

被引:71
|
作者
Slama, M
Susic, D
Varagic, J
Ahn, J
Frohlich, ED
机构
[1] Alton Ochsner Med Fdn & Ochsner Clin, Div Res, New Orleans, LA 70121 USA
[2] Univ Picardie, Fac Med, Lab Pharmacol & Physiopathol Cardiovasc, F-80054 Amiens, France
关键词
Doppler; blood volume changes;
D O I
10.1152/ajpheart.00653.2002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The systematic evaluation of different transthoracic echocardiographic (TTE) methods to determine cardiac output (CO) and the effect of changes in intravascular volume on echocardiographically determined indexes of cardiovascular structure in the rat has not been documented. With the use of 11 Wistar rats, simultaneous echocardiographic and thermodilution measurements of CO were compared at baseline and after blood withdrawal or transfusion at 43 different levels of intravascular volume and using 10 different echocardiographic approaches. The best correlation (r = 0.93; P < 0.0001), least bias (-3 ml/min), and best precision (16 ml/min) between thermodilution and echocardiographic methods were obtained at the level of aortic annulus using pulsed Doppler. In conclusion, CO could be accurately assessed in rats using TTE and pulsed Doppler at the level of the aortic annulus. This annulus was demonstrated to remain stable, but pulmonary annulus, thoracic aorta, mitral valve, and left ventricular diameters were found to be more modifiable during volumic changes.
引用
收藏
页码:H691 / H697
页数:7
相关论文
共 50 条
  • [41] MEASUREMENT OF CARDIAC-OUTPUT
    NIGHTINGALE, P
    EDWARDS, JD
    MORTIMER, AJ
    LANCET, 1988, 2 (8611): : 635 - 635
  • [42] MEASUREMENT OF CARDIAC-OUTPUT
    不详
    LANCET, 1988, 2 (8605): : 257 - 258
  • [43] MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION
    SANMARCO, ME
    DAVILA, JC
    DISEASES OF THE CHEST, 1969, 56 (03): : 268 - &
  • [44] THE ELECTRONIC MEASUREMENT OF CARDIAC OUTPUT
    SCHENK, WG
    PORTIN, BA
    LESLIE, MB
    SURGERY, 1958, 44 (02) : 333 - 337
  • [45] MEASUREMENT OF CARDIAC-OUTPUT
    RAWLES, J
    LANCET, 1988, 2 (8609): : 515 - 515
  • [46] MEASUREMENT OF THE CARDIAC OUTPUT IN MAN
    Cooke, A. M.
    Priestley, J. G.
    JOURNAL OF PHYSIOLOGY-LONDON, 1937, 90 (01): : 104 - 112
  • [47] MEASUREMENT OF DISTRIBUTION OF CARDIAC OUTPUT
    KAIHARA, S
    VANHEERD.PD
    MIGITA, T
    WAGNER, HN
    JOURNAL OF APPLIED PHYSIOLOGY, 1968, 25 (06) : 696 - &
  • [48] New method of cardiac output measurement using ultrasound velocity dilution in rats
    Veal, N
    Moal, F
    Wang, JH
    Vuillemin, E
    Oberti, F
    Roy, E
    Kaassis, M
    Trouvé, R
    Saumet, JL
    Calès, P
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (03) : 1274 - 1282
  • [49] A THERMAL DILUTION SYSTEM FOR CHRONIC MEASUREMENT OF CARDIAC-OUTPUT IN CONSCIOUS RATS
    MAZZEO, AJ
    OSBORN, JW
    BARBER, BJ
    QUILLEN, EW
    COWLEY, AW
    FEDERATION PROCEEDINGS, 1984, 43 (03) : 731 - 731
  • [50] CHRONIC MEASUREMENT OF CARDIAC-OUTPUT IN UNANESTHETIZED RATS USING MINIATURE THERMOCOUPLES
    OSBORN, JW
    BARBER, BJ
    QUILLEN, EW
    ABRAM, RJ
    COWLEY, AW
    AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (06): : H1365 - H1372