TRANSESOPHAGEAL ECHOCARDIOGRAPHIC MEASUREMENTS OF CARDIAC-OUTPUT IN CARDIAC SURGICAL PATIENTS

被引:13
|
作者
IZZAT, MB
REGRAGUI, IA
WILDE, P
ANGELINI, GD
BRYAN, AJ
机构
[1] UNIV BRISTOL,DEPT CARDIAC SURG,BRISTOL,AVON,ENGLAND
[2] UNIV BRISTOL,DEPT RADIOL,BRISTOL,AVON,ENGLAND
来源
ANNALS OF THORACIC SURGERY | 1994年 / 58卷 / 05期
关键词
D O I
10.1016/0003-4975(94)91941-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transesophageal echocardiography is becoming increasingly popular as a method of intraoperative monitoring because it can be performed continuously, does not transgress the sterile operative field, and provides data with regard to valve function, ventricular volumes, and contractility. Recently it was suggested that it can be used to measure cardiac output; however, controversy remains regarding its accuracy. Cardiac output was measured simultaneously by transesophageal echocardiography (using a 5-MHz pulse-wave Doppler, single-plane viewing probe) and by the thermodilution method in 21 patients undergoing open heart operations. The cardiac outputs measured by thermodilution correlated poorly (r = 0.45) with the transesophageal values derived from the left ventricular cross-sectional area, and the mean difference was 0.47 +/- 2.17 (standard deviation)L.min(-1), giving limits of agreement of from -3.87 to +4.81 L.min(-1). Cardiac outputs measured by thermodilution correlated well (r = 0.95) with transesophageal Doppler values derived from pulmonary artery flow velocity, with a mean difference of 0.12 +/- 0.45 L.min(-1) and narrow limits of agreement of from -0.78 to +1.02 L.min(-1). Based on our findings, transesophageal Doppler echocardiographic determination of cardiac output using pulmonary artery now measurements can provide accurate hemodynamic data in patients undergoing cardiac operations.
引用
收藏
页码:1486 / 1489
页数:4
相关论文
共 50 条
  • [1] MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC DOPPLER IMAGING ACCURATELY DETERMINES CARDIAC-OUTPUT MEASUREMENTS IN CRITICALLY ILL PATIENTS
    FEINBERG, MS
    HOPKINS, WE
    DAVILAROMAN, VG
    BARZILAI, B
    CHEST, 1995, 107 (03) : 769 - 773
  • [2] TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT BY THE MITRAL ANNULUS METHOD
    SHIMAMOTO, H
    KITO, H
    KAWAZOE, K
    FUJITA, T
    SHIMAMOTO, Y
    BRITISH HEART JOURNAL, 1992, 68 (05): : 510 - 515
  • [3] CARDIAC-OUTPUT DETERMINATIONS IN SURGICAL PATIENTS
    TIETJEN, GW
    GUMP, FE
    KINNEY, JM
    SURGICAL CLINICS OF NORTH AMERICA, 1975, 55 (03) : 521 - 529
  • [4] DOPPLER ESTIMATION OF CARDIAC-OUTPUT WITHOUT ECHOCARDIOGRAPHIC AREA MEASUREMENTS
    JAWAD, IA
    GHALI, MH
    BROWN, RL
    SOHN, YH
    CHEST, 1986, 89 (06) : S527 - S527
  • [5] SPONTANEOUS VARIABILITY AND REPRODUCIBILITY OF DOPPLER ECHOCARDIOGRAPHIC MEASUREMENTS OF CARDIAC-OUTPUT IN INFANCY
    STERN, H
    HABERHAUER, P
    BUHLMEYER, K
    EMMRICH, P
    WIENER KLINISCHE WOCHENSCHRIFT, 1988, 100 (19) : 648 - 652
  • [6] THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS
    GIBNEY, RTN
    RYAN, H
    CRITICAL CARE MEDICINE, 1984, 12 (07) : 614 - 615
  • [7] COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS
    APPEL, PL
    KRAM, HB
    MACKABEE, J
    FLEMING, AW
    SHOEMAKER, WC
    CRITICAL CARE MEDICINE, 1986, 14 (11) : 933 - 935
  • [8] DOPPLER-ECHOCARDIOGRAPHIC ASSESSMENT OF CARDIAC-OUTPUT
    ASCAH, KJ
    STEWART, WJ
    LEVINE, RA
    WEYMAN, AE
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1985, 23 (04) : 659 - 670
  • [9] PROBLEMS OF THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS IN SMALL PATIENTS
    ALLAN, AJ
    MCQUILLAN, PJ
    ANAESTHESIA, 1992, 47 (09) : 808 - 809
  • [10] EFFECT OF INJECTATE TEMPERATURE ON MEASUREMENT OF THERMODILUTION CARDIAC-OUTPUT IN CARDIAC SURGICAL PATIENTS
    HRUBY, IM
    WOODS, SL
    CIRCULATION, 1983, 68 (04) : 222 - 222