TRANSESOPHAGEAL ECHOCARDIOGRAPHIC MEASUREMENTS OF CARDIAC-OUTPUT IN CARDIAC SURGICAL PATIENTS

被引:13
|
作者
IZZAT, MB
REGRAGUI, IA
WILDE, P
ANGELINI, GD
BRYAN, AJ
机构
[1] UNIV BRISTOL,DEPT CARDIAC SURG,BRISTOL,AVON,ENGLAND
[2] UNIV BRISTOL,DEPT RADIOL,BRISTOL,AVON,ENGLAND
来源
ANNALS OF THORACIC SURGERY | 1994年 / 58卷 / 05期
关键词
D O I
10.1016/0003-4975(94)91941-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transesophageal echocardiography is becoming increasingly popular as a method of intraoperative monitoring because it can be performed continuously, does not transgress the sterile operative field, and provides data with regard to valve function, ventricular volumes, and contractility. Recently it was suggested that it can be used to measure cardiac output; however, controversy remains regarding its accuracy. Cardiac output was measured simultaneously by transesophageal echocardiography (using a 5-MHz pulse-wave Doppler, single-plane viewing probe) and by the thermodilution method in 21 patients undergoing open heart operations. The cardiac outputs measured by thermodilution correlated poorly (r = 0.45) with the transesophageal values derived from the left ventricular cross-sectional area, and the mean difference was 0.47 +/- 2.17 (standard deviation)L.min(-1), giving limits of agreement of from -3.87 to +4.81 L.min(-1). Cardiac outputs measured by thermodilution correlated well (r = 0.95) with transesophageal Doppler values derived from pulmonary artery flow velocity, with a mean difference of 0.12 +/- 0.45 L.min(-1) and narrow limits of agreement of from -0.78 to +1.02 L.min(-1). Based on our findings, transesophageal Doppler echocardiographic determination of cardiac output using pulmonary artery now measurements can provide accurate hemodynamic data in patients undergoing cardiac operations.
引用
收藏
页码:1486 / 1489
页数:4
相关论文
共 50 条
  • [21] LIMITATIONS OF CARDIAC-OUTPUT MEASUREMENTS BY THERMODILUTION
    NADEAU, S
    NOBLE, WH
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1986, 33 (06) : 780 - 784
  • [22] DETERMINATION OF CARDIAC-OUTPUT IN PATIENTS
    COTES, JE
    CLINICAL SCIENCE, 1983, 65 (04) : 447 - 447
  • [23] UTILITY AND LIMITATIONS OF BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC AUTOMATED BORDER DETECTION TO DETERMINE STROKE VOLUME AND CARDIAC-OUTPUT
    KATZ, WE
    GASIOR, TA
    REDDY, SCB
    GORCSAN, J
    CLINICAL RESEARCH, 1993, 41 (03): : A637 - A637
  • [24] PULSED DOPPLER TRANSESOPHAGEAL ECHOCARDIOGRAPHIC DETERMINATION OF CARDIAC-OUTPUT IN HUMAN-BEINGS - COMPARISON WITH THERMODILUTION TECHNIQUE
    STODDARD, MF
    PRINCE, CR
    AMMASH, N
    GOAD, JL
    VOGEL, RL
    AMERICAN HEART JOURNAL, 1993, 126 (04) : 956 - 962
  • [25] NOVEL DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF RESTING CARDIAC-OUTPUT
    ACTON, G
    BROOM, C
    WAREHAM, K
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 1989, 45 (02) : 169 - 169
  • [26] Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients
    Axler, O
    Tousignant, C
    Thompson, CR
    DallavaSantucci, J
    Phang, PT
    Russell, JA
    Walley, KR
    JOURNAL OF CRITICAL CARE, 1996, 11 (03) : 109 - 116
  • [27] PRECISION OF IMPEDANCE CARDIOGRAPHY MEASUREMENTS OF CARDIAC-OUTPUT IN PACEMAKER PATIENTS
    OVSYSHCHER, I
    GROSS, JN
    BLUMBERG, S
    FURMAN, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 1923 - 1926
  • [28] DOPPLER-ECHOCARDIOGRAPHIC MEASUREMENT OF CARDIAC-OUTPUT AT THE LEVEL OF THE 4 CARDIAC VALVES
    GAUDREAULT, G
    DUMESNIL, JG
    LEBLANC, MH
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1992, 41 (05): : 267 - 271
  • [29] INTRAOPERATIVE ESTIMATION OF CARDIAC-OUTPUT BY TRANSESOPHAGEAL PULSED DOPPLER ECHOCARDIOGRAPHY
    MUHIUDEEN, IA
    KUECHERER, HF
    LEE, E
    CAHALAN, MK
    SCHILLER, NB
    ANESTHESIOLOGY, 1991, 74 (01) : 9 - 14
  • [30] TRANSESOPHAGEAL DOPPLER ULTRASONOGRAPHY - EVIDENCE FOR IMPROVED CARDIAC-OUTPUT MONITORING
    PERRINO, AC
    FLEMING, J
    LAMANTIA, KR
    ANESTHESIA AND ANALGESIA, 1990, 71 (06): : 651 - 657