A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy

被引:53
|
作者
Wang, RQ [1 ]
Li, XA [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
Monte Carlo; dosimetry; intravascular brachytherapy;
D O I
10.1118/1.1319374
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The AAPM TG-60 report has proposed various dose calculation parameters for intravascular brachytherapy (IVBT). These parameters include the dose rate constant (or the dose rate at a reference position for a beta-particle emitting source), the radial dose function, and the anisotropy function. In this work, we have used a modified EGS4 Monte Carlo system to calculate these parameters for the two most commonly used IVBT sources (the beta-particle emitting Sr-90/Y-90 source and the photon emitting Ir-192 SS source). To ensure the calculation accuracy, the present calculation was compared with several measurements and calculations reported by other authors. Excellent agreement was found for the results with the photon source. For beta-particle source calculation, the present results for a variety of point sources agree very well with a previous work. The presently calculated radial dose functions for the Sr-90/Y-90 source are consistent with those of a published work for intermediate radial distances. The dose uniformity in the axial direction was also studied. The contributions of bremsstrahlung photons to total doses for the Sr-90/Y-90 beta source, and the influence of ignoring electron transport on calculated doses for the Ir-192 SS photon source are discussed. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01211-6].
引用
收藏
页码:2528 / 2535
页数:8
相关论文
共 50 条
  • [31] Dosimetric Study of HDR 192Ir and LDR 125I Brachytherapy Sources Using the Penelope Monte Carlo Code
    Benhabib, S. M.
    Zhu, D.
    Austerlitz, C.
    Mota, H.
    Sempau, J.
    Allison, R.
    Sibata, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [32] Dose Calculation in the Water Phantom for 90Sr/90Y Beta Particles Using MCNP Code
    Mowlavi, Ali Asghar
    Binesh, Alireza
    Rejaei, Mohammad
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2028 - +
  • [33] Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method
    Rostami, Atefeh
    Hoseini, Mahdi
    Ghorbani, Mahdi
    Knaup, Courtney
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 139 - 145
  • [34] Dosimetric and radiobiological comparison of TG-43 and Monte Carlo calculations in 192Ir breast brachytherapy applications
    Peppa, V.
    Pappas, E. P.
    Karaiskos, P.
    Major, T.
    Polgar, C.
    Papagiannis, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1245 - 1251
  • [35] An electrochemical pathway to prepare circular planar 90Sr/90Y sources for the calibration of surface contamination monitors
    Manoj Kumar
    Shyamala S. Gandhi
    J. Nuwad
    J. Udhayakumar
    Ashutosh Dash
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 302 : 709 - 719
  • [36] An electrochemical pathway to prepare circular planar 90Sr/90Y sources for the calibration of surface contamination monitors
    Kumar, Manoj
    Gandhi, Shyamala S.
    Nuwad, J.
    Udhayakumar, J.
    Dash, Ashutosh
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 302 (01) : 709 - 719
  • [37] Characterization of a high-dose-rate 90Sr-90Y source for intravascular brachytherapy by using the Monte Carlo code PENELOPE
    Asenjo, J
    Fernández-Varea, JM
    Sánchez-Reyes, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (05): : 697 - 711
  • [38] Monte Carlo modeling and dosimetric validation of GammaMed Plus 192Ir source for HDR brachytherapy application using TOPAS
    Shende, Ravindra
    Dhoble, S. J.
    Gayake, Umesh
    APPLIED RADIATION AND ISOTOPES, 2025, 215
  • [39] The spatial variation of dose-rate from 90Sr/90Y beta sources for use in luminescence dating
    Spooner, NA
    Allsop, A
    RADIATION MEASUREMENTS, 2000, 32 (01) : 49 - 56
  • [40] A novel method for the preparation of large-area 90Sr/90Y sources for the calibration of hand contamination monitors
    Kumar, Manoj
    Gandhi, Shyamala S.
    Chakravarty, Rubel
    Nuwad, J.
    Udhayakumar, J.
    Dash, Ashutosh
    APPLIED RADIATION AND ISOTOPES, 2013, 79 : 5 - 11