A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy

被引:53
|
作者
Wang, RQ [1 ]
Li, XA [1 ]
机构
[1] Univ Maryland, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
Monte Carlo; dosimetry; intravascular brachytherapy;
D O I
10.1118/1.1319374
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The AAPM TG-60 report has proposed various dose calculation parameters for intravascular brachytherapy (IVBT). These parameters include the dose rate constant (or the dose rate at a reference position for a beta-particle emitting source), the radial dose function, and the anisotropy function. In this work, we have used a modified EGS4 Monte Carlo system to calculate these parameters for the two most commonly used IVBT sources (the beta-particle emitting Sr-90/Y-90 source and the photon emitting Ir-192 SS source). To ensure the calculation accuracy, the present calculation was compared with several measurements and calculations reported by other authors. Excellent agreement was found for the results with the photon source. For beta-particle source calculation, the present results for a variety of point sources agree very well with a previous work. The presently calculated radial dose functions for the Sr-90/Y-90 source are consistent with those of a published work for intermediate radial distances. The dose uniformity in the axial direction was also studied. The contributions of bremsstrahlung photons to total doses for the Sr-90/Y-90 beta source, and the influence of ignoring electron transport on calculated doses for the Ir-192 SS photon source are discussed. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01211-6].
引用
收藏
页码:2528 / 2535
页数:8
相关论文
共 50 条
  • [1] Monte Carlo calculation of a 90Sr/90Y and an 192Ir sources for intravascular brachytherapy
    Wang, RQ
    Li, XA
    Yu, CX
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2682 - 2684
  • [2] Dosimetric comparison of two 90Sr/90Y sources for intravascular brachytherapy:: an EGSnrc Monte Carlo calculation
    Wang, RQ
    Li, XA
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (23): : 4259 - 4269
  • [3] Monte Carlo dose characterization of a new 90Sr/90Y source with balloon for intravascular brachytherapy
    Wang, RQ
    Li, XA
    Lobdell, J
    MEDICAL PHYSICS, 2003, 30 (01) : 27 - 33
  • [4] Dosimetric characterization of a new 90Sr/90Y source with balloon for intravascular brachytherapy
    Wang, R
    Li, XA
    Lobdell, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1318 - 1319
  • [5] A comparison of Monte Carlo and TG60 algorithm calculation in the dosimetry of 90Sr/90Y seed source trains for intravascular brachytherapy
    Saiani, F
    Galelli, M
    Feroldi, P
    PHYSICA MEDICA, 2004, 20 (04) : 147 - 154
  • [6] Monte Carlo parametric study of stent impact on dose for catheter-based intravascular brachytherapy with 90Sr/90Y
    Ortego, PM
    Prieto, C
    Vano, E
    MEDICAL PHYSICS, 2004, 31 (07) : 1964 - 1971
  • [7] Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy
    Miften, MM
    Das, SK
    Shafman, TD
    Marks, LB
    MEDICAL PHYSICS, 2002, 29 (12) : 2891 - 2896
  • [8] Conjuctival carcinoma treated by brachytherapy with 90SR/90Y
    Jancar, B.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S252 - S253
  • [9] The effect of pull back technique on dose distribution in the junction region for 90Sr/90Y intravascular brachytherapy sources
    Demir, B
    Bilge, H
    Dincbas, FO
    Koca, A
    Karacam, S
    Gunhan, B
    RADIATION MEASUREMENTS, 2005, 39 (01) : 29 - 32
  • [10] Evaluation of dosimetric parameters for various 192ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation
    Devan, Krishnamurthy
    Aruna, Prakasarao
    Manigandan, Durai
    Bharanidharan, Ganesan
    Subbaiah, Kamatam Venkata
    Sunny, Chiravath Sunil
    Ganesan, Singaravelu
    MEDICAL DOSIMETRY, 2007, 32 (04) : 305 - 315