The determination of glutamine with flow-injection chemiluminescence detection and mechanism study

被引:7
|
作者
Liu, Yan-Ming [1 ]
Liu, Zhuan-Li [1 ]
Shi, Yan-Mei [1 ]
Tian, Wei [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Xinyang 464000, Peoples R China
基金
中国国家自然科学基金;
关键词
glutamine; chemiluminescence; flow-injection; mechanism study; AMINO-ACIDS; CAPILLARY-ELECTROPHORESIS; LUMINOL; NUTRITION; FLUIDS; MEDIA; ASSAY;
D O I
10.1002/bio.1143
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The main purpose of this study was to develop an inexpensive, simple, rapid and sensitive chemiluminescence (CL) method for the determination of glutamine (Gln) using a flow-injection (FI) system. Gin was found to strongly inhibit the CL signal of the luminol-H2O2-CuSO4 system in Na2B4O7 solution. A new FI-CL method was developed for the determination of Gin. Parameters affecting the reproducibility and CL detection were optimized systematically. Under the optimized conditions, the corresponding linear regression equation was established over the range of 5.0 x 10(-7) to 2.5 x 10(-6) mol/L with the detection limit of 1.8 x 10(-8) mol/L. The relative standard deviation was found to be 1.8% for 11 replicate determinations of 1.5 x 10(-6) mol/L Gln. The proposed method has been satisfactorily applied for the determination of Gln in real samples (Marzulene-s granules) with recoveries in the range of 98.7-108.6%. The minimum sampling rate was about 100 samples/h. The possible mechanism of this inhibitory CL was studied by fluorescence spectrophotometer and UV-vis spectrophotometer. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 50 条
  • [11] Flow-injection determination of trace amounts of dopamine by chemiluminescence detection
    Zhang, LH
    Teshima, N
    Hasebe, T
    Kurihara, M
    Kawashima, T
    TALANTA, 1999, 50 (03) : 677 - 683
  • [12] Determination of norfloxacin by flow-injection chemiluminescence
    Liao, SL
    Xie, ZH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (12) : 1938 - 1942
  • [13] Photodegradation and flow-injection determination of simetryn herbicide by luminol chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2008, 24 (08) : 979 - 983
  • [14] Photodegradation and Flow-Injection Determination of Simetryn Herbicide by Luminol Chemiluminescence Detection
    Amir Waseem
    Mohammad Yaqoob
    Abdul Nabi
    Analytical Sciences, 2008, 24 : 979 - 983
  • [15] DETERMINATION OF TRACE AMOUNTS OF UREA BY USING FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    HU, XC
    TAKENAKA, N
    KITANO, M
    BANDOW, H
    MAEDA, Y
    HATTORI, M
    ANALYST, 1994, 119 (08) : 1829 - 1833
  • [16] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao Zhi-ming
    Zou Ping
    Chen Mei
    Xiu Fu-rong
    Chen Yu-lin
    Hong Ke-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (02) : 269 - 272
  • [17] Determination of isoniazid by flow-injection chemiluminescence analysis
    Qu, P
    Li, BX
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 665 - 667
  • [18] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [19] Flow-injection chemiluminescence sensor for the determination of isoniazid
    Zhang, SC
    Li, H
    ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 287 - 294
  • [20] Flow-injection chemiluminescence determination of formaldehyde in water
    Motyka, Kamil
    Onjia, Antonije
    Mikuska, Pavel
    Vecera, Zbynek
    TALANTA, 2007, 71 (02) : 900 - 905