Photodegradation and flow-injection determination of simetryn herbicide by luminol chemiluminescence detection

被引:10
|
作者
Waseem, Amir [1 ]
Yaqoob, Mohammad [1 ]
Nabi, Abdul [1 ]
机构
[1] Univ Balochistan, Dept Chem, Quetta, Pakistan
关键词
D O I
10.2116/analsci.24.979
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and simple flow injection chemiluminescence method is reported for the determination of simetryn, a common herbicide. The method is based on the direct oxidation of luminol by the photoproducts of the simetryn in alkaline medium in the absence of catalyst/oxidant. The linear concentration range was 0.01 - 2 mu g mL(-1) simetryn with a correlation coefficient (r(2)) of 0.9997 and relative standard deviations (RSD; n = 4) in the range of 0.9 - 2.3%. The limit of detection (S/N = 3) was 7.5 ng mL(-1) with a sample throughput of 100 h(-1). The proposed method has been applied to determine simetryn in natural waters using Sep-Pak C-18 cartridges for solid phase extraction (SPE) procedure. The recoveries were in the range of 97 +/- 1 to 104 +/- 2%. The mechanism of chemiluminescence reaction has also been discussed briefly.
引用
收藏
页码:979 / 983
页数:5
相关论文
共 50 条
  • [1] Photodegradation and Flow-Injection Determination of Simetryn Herbicide by Luminol Chemiluminescence Detection
    Amir Waseem
    Mohammad Yaqoob
    Abdul Nabi
    Analytical Sciences, 2008, 24 : 979 - 983
  • [2] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    LUMINESCENCE, 2012, 27 (05) : 419 - 425
  • [3] Flow-injection electrogenerated chemiluminescence determination of epinephrine using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICA CHIMICA ACTA, 2001, 441 (01) : 81 - 86
  • [4] Flow-injection electrogenerated chemiluminescence determination of isoniazid using luminol
    Zheng, XW
    Guo, ZH
    Zhang, ZJ
    ANALYTICAL SCIENCES, 2001, 17 (09) : 1095 - 1099
  • [5] Flow-Injection Electrogenerated Chemiluminescence Determination of Isoniazid Using Luminol
    Xingwang Zheng
    Zhihui Guo
    Zhujun Zhang
    Analytical Sciences, 2001, 17 : 1095 - 1099
  • [6] Photodegradation and Flow-Injection Determination of Dithiocarbamate Fungicides in Natural Water with Chemiluminescence Detection
    Amir Waseem
    Mohammad Yaqoob
    Abdul Nabi
    Analytical Sciences, 2009, 25 : 395 - 400
  • [7] Photodegradation and Flow-Injection Determination of Dithiocarbamate Fungicides in Natural Water with Chemiluminescence Detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2009, 25 (03) : 395 - 400
  • [8] Flow-Injection Determination of Ornidazole by Chemiluminescence Detection Basedon a Luminol-Ferricyanide Reaction
    Yi Lv
    Zhujun Zhang
    Deyong He
    Yufei Hu
    Analytical Sciences, 2003, 19 : 625 - 626
  • [9] Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    LUMINESCENCE, 2008, 23 (03) : 144 - 149
  • [10] Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction
    Lv, Y
    Zhang, ZJ
    He, DY
    Hu, YF
    ANALYTICAL SCIENCES, 2003, 19 (04) : 625 - 627