Flow-injection determination of ornidazole by chemiluminescence detection based on a luminol-ferricyanide reaction

被引:14
|
作者
Lv, Y [1 ]
Zhang, ZJ [1 ]
He, DY [1 ]
Hu, YF [1 ]
机构
[1] SW Normal Univ, Dept Chem, Inst Analyt Sci, Chongqing 400715, Peoples R China
关键词
D O I
10.2116/analsci.19.625
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection analysis (FIA) with a chemiluminescence detection method was developed for the determination of ornidazole based on the inhibition intensity of chemiluminescence from the luminol-ferricyanide system. Under the condition of 1.0 x 10(-3) mol/L luminol and 5.0 x 10(-6) mol/L potassium ferricyanide, the response to the concentration of ornidazole is linear from 0.2 mug ml(-1) to 10 mug ml(-1), and a detection limit of 0.05 mug ml(-1) can be obtained. This method has been successfully applied to the determination of ornidazole in pharmaceutical preparations.
引用
收藏
页码:625 / 627
页数:3
相关论文
共 50 条
  • [1] Flow-Injection Determination of Ornidazole by Chemiluminescence Detection Basedon a Luminol-Ferricyanide Reaction
    Yi Lv
    Zhujun Zhang
    Deyong He
    Yufei Hu
    Analytical Sciences, 2003, 19 : 625 - 626
  • [2] Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
    Wang, ZP
    Zhang, ZJ
    Zhang, XO
    Fu, ZF
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) : 1 - 7
  • [3] Flow-injection chemiluminescence determination of thiamine by enhancement of the luminol-ferricyanide system
    Li, Y.
    Yang, Y.
    Lu, J.
    LUMINESCENCE, 2008, 23 (02) : 81 - 81
  • [4] Flow injection chemiluminescence determination of captopril based on its enhancing effect on the luminol-ferricyanide/ferrocyanide reaction
    Du, JX
    Li, YH
    Lu, JR
    LUMINESCENCE, 2002, 17 (03) : 165 - 167
  • [5] Flow injection chemiluminescence determination of dobutamine hydrochloride injection using luminol-ferricyanide/ferrocyanide system
    Liu, HY
    Zhang, L
    Zhou, JM
    Hao, YH
    He, PG
    Fang, YZ
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 125 - 129
  • [6] Flow injection chemiluminescence determination of polyhydroxy phenols using luminol-ferricyanide/ferrocyanide system
    Du, JX
    Li, YH
    Lu, JR
    TALANTA, 2001, 55 (06) : 1055 - 1058
  • [7] Flow injection chemiluminescence determination of rutin based on its enhancing effect on the luminol-ferricyanide/ferrocyanide system
    Du, JX
    Li, YH
    Lu, JR
    ANALYTICAL LETTERS, 2001, 34 (10) : 1741 - 1748
  • [8] Photodegradation and flow-injection determination of simetryn herbicide by luminol chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2008, 24 (08) : 979 - 983
  • [9] Photodegradation and Flow-Injection Determination of Simetryn Herbicide by Luminol Chemiluminescence Detection
    Amir Waseem
    Mohammad Yaqoob
    Abdul Nabi
    Analytical Sciences, 2008, 24 : 979 - 983
  • [10] Flow-injection chemiluminescence determination of phentolamine based on its enhancing effect on the luminol-potassium ferricyanide system
    Huang, YM
    Liu, WB