Photodegradation and flow-injection determination of simetryn herbicide by luminol chemiluminescence detection

被引:10
|
作者
Waseem, Amir [1 ]
Yaqoob, Mohammad [1 ]
Nabi, Abdul [1 ]
机构
[1] Univ Balochistan, Dept Chem, Quetta, Pakistan
关键词
D O I
10.2116/analsci.24.979
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and simple flow injection chemiluminescence method is reported for the determination of simetryn, a common herbicide. The method is based on the direct oxidation of luminol by the photoproducts of the simetryn in alkaline medium in the absence of catalyst/oxidant. The linear concentration range was 0.01 - 2 mu g mL(-1) simetryn with a correlation coefficient (r(2)) of 0.9997 and relative standard deviations (RSD; n = 4) in the range of 0.9 - 2.3%. The limit of detection (S/N = 3) was 7.5 ng mL(-1) with a sample throughput of 100 h(-1). The proposed method has been applied to determine simetryn in natural waters using Sep-Pak C-18 cartridges for solid phase extraction (SPE) procedure. The recoveries were in the range of 97 +/- 1 to 104 +/- 2%. The mechanism of chemiluminescence reaction has also been discussed briefly.
引用
收藏
页码:979 / 983
页数:5
相关论文
共 50 条
  • [41] Determination of trace amounts of dopamine by flow-injection analysis coupled with luminol-Ag(III) complex chemiluminescence detection
    Xu, Xiangdong
    Shi, Hongmei
    Ma, Li
    Kang, Weijun
    Li, Shan
    LUMINESCENCE, 2011, 26 (02) : 93 - 100
  • [42] Determination of thyroxine in pharmaceuticals using flow injection with luminol chemiluminescence inhibition detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    LUMINESCENCE, 2006, 21 (03) : 174 - 178
  • [43] Determination of Nitrite and Nitrate in Freshwaters using Flow Injection Luminol Chemiluminescence Detection
    Attiq-ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    ACTA CHIMICA SLOVENICA, 2011, 58 (03) : 569 - 575
  • [44] Determination of iron in blood serum using flow injection with luminol chemiluminescence detection
    Waseem, A
    Yaqoob, M
    Nabi, A
    LUMINESCENCE, 2004, 19 (06) : 333 - 338
  • [45] DETERMINATION OF TRACE AMOUNTS OF UREA BY USING FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    HU, XC
    TAKENAKA, N
    KITANO, M
    BANDOW, H
    MAEDA, Y
    HATTORI, M
    ANALYST, 1994, 119 (08) : 1829 - 1833
  • [46] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao Zhi-ming
    Zou Ping
    Chen Mei
    Xiu Fu-rong
    Chen Yu-lin
    Hong Ke-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (02) : 269 - 272
  • [47] Determination of isoniazid by flow-injection chemiluminescence analysis
    Qu, P
    Li, BX
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 665 - 667
  • [48] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [49] Flow-injection chemiluminescence sensor for the determination of isoniazid
    Zhang, SC
    Li, H
    ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 287 - 294
  • [50] Flow-injection chemiluminescence determination of formaldehyde in water
    Motyka, Kamil
    Onjia, Antonije
    Mikuska, Pavel
    Vecera, Zbynek
    TALANTA, 2007, 71 (02) : 900 - 905