Simple procedure for optimizing model of NaI(Tl) detector using Monte Carlo simulation

被引:15
|
作者
Truong Thanh Sang [1 ]
Huynh Dinh Chuong [2 ]
Hoang Duc Tam [1 ]
机构
[1] Ho Chi Minh City Univ Educ, Fac Phys, 280 An Duong Vuong St,Dist 5, Ho Chi Minh City, Vietnam
[2] VNUHCM Univ Sci, Nucl Tech Lab, Ho Chi Minh City, Vietnam
关键词
Efficiency; MCNP; NaI(Tl) detector; Optimize; Simple procedure; HPGE DETECTOR; GAMMA-RAY; EFFICIENCY; MCNP; CALIBRATION; VALIDATION;
D O I
10.1007/s10967-019-06787-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study proposed a simple procedure for optimizing the model of NaI(Tl) detector. The procedure considers using linear functions for describing the dependence of efficiency on each specification of detector using Monte Carlo simulation. The measurements were performed to determine the efficiency of detector using point calibration sources. Using these efficiencies, the optimized specifications were interpolated based on the above linear functions. The validation of optimized model was carried out by experimentally determining the efficiencies of detector and estimating the radioactivities of K-40, U-238, and Th-232 isotopes in reference samples. The obtained results showed good agreement between experiment and simulation.
引用
收藏
页码:1039 / 1048
页数:10
相关论文
共 50 条
  • [21] MONTE CARLO CALCULATION OF NaI(Tl) DETECTOR RESPONSE FUNCTIONS FOR LOW ENERGY GAMMA RAYS.
    Saito, Kimiaki
    Moriuchi, Shigeru
    Nuclear instruments and methods in physics research, 1984, 226 (2-3): : 449 - 454
  • [22] MONTE-CARLO CALCULATION OF ACCURATE RESPONSE FUNCTIONS FOR A NAI(TL) DETECTOR FOR GAMMA-RAYS
    SAITO, K
    MORIUCHI, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 185 (1-3): : 299 - 308
  • [23] Kinetic Monte Carlo Simulations of Scintillation Processes in NaI(Tl)
    Kerisit, Sebastien
    Wang, Zhiguo
    Williams, Richard T.
    Grim, Joel Q.
    Gao, Fei
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (02) : 860 - 869
  • [24] Monte Carlo simulation of GM probe and NaI detector efficiency for surface activity measurements
    Grujic, Selena
    Dordevic, Ivana
    Milosevic, Miodrag
    Kozmidis-Luburic, Uranija
    RADIATION MEASUREMENTS, 2013, 58 : 45 - 51
  • [25] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    GONG ChunHui
    ZENG GuoQiang
    GE LiangQuan
    TANG Xiaobin
    TAN ChengJun
    Science China(Technological Sciences), 2014, (09) : 1840 - 1845
  • [26] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    GONG ChunHui
    ZENG GuoQiang
    GE LiangQuan
    TANG Xiaobin
    TAN ChengJun
    Science China(Technological Sciences), 2014, 57 (09) : 1840 - 1845
  • [27] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    Gong ChunHui
    Zeng GuoQiang
    Ge LiangQuan
    Tang Xiaobin
    Tan ChengJun
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (09) : 1840 - 1845
  • [28] Monte Carlo simulation of the response of a large NaI(Tl) total absorption spectrometer for β-decay studies
    Cano-Ott, D
    Tain, JL
    Gadea, A
    Rubio, B
    Batist, L
    Karny, M
    Roeckl, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 430 (2-3): : 333 - 347
  • [29] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    ChunHui Gong
    GuoQiang Zeng
    LiangQuan Ge
    Xiaobin Tang
    ChengJun Tan
    Science China Technological Sciences, 2014, 57 : 1840 - 1845
  • [30] Simulation of Energy Absorption Spectrum in NaI Crystal Detector for Multiple Gamma Energy Using Monte Carlo Method
    Wirawan, Rahadi
    Waris, Abdul
    Djamal, Mitra
    Handayani, Gunawan
    5TH ASIAN PHYSICS SYMPOSIUM (APS 2012), 2015, 1656