Simple procedure for optimizing model of NaI(Tl) detector using Monte Carlo simulation

被引:15
|
作者
Truong Thanh Sang [1 ]
Huynh Dinh Chuong [2 ]
Hoang Duc Tam [1 ]
机构
[1] Ho Chi Minh City Univ Educ, Fac Phys, 280 An Duong Vuong St,Dist 5, Ho Chi Minh City, Vietnam
[2] VNUHCM Univ Sci, Nucl Tech Lab, Ho Chi Minh City, Vietnam
关键词
Efficiency; MCNP; NaI(Tl) detector; Optimize; Simple procedure; HPGE DETECTOR; GAMMA-RAY; EFFICIENCY; MCNP; CALIBRATION; VALIDATION;
D O I
10.1007/s10967-019-06787-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study proposed a simple procedure for optimizing the model of NaI(Tl) detector. The procedure considers using linear functions for describing the dependence of efficiency on each specification of detector using Monte Carlo simulation. The measurements were performed to determine the efficiency of detector using point calibration sources. Using these efficiencies, the optimized specifications were interpolated based on the above linear functions. The validation of optimized model was carried out by experimentally determining the efficiencies of detector and estimating the radioactivities of K-40, U-238, and Th-232 isotopes in reference samples. The obtained results showed good agreement between experiment and simulation.
引用
收藏
页码:1039 / 1048
页数:10
相关论文
共 50 条
  • [31] Evaluation of transmission detector model using Monte Carlo simulation of VMAT delivery
    Johnson, D.
    Thwaites, D.
    Cosgrove, V.
    Weston, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S695 - S695
  • [32] Monte Carlo calculation of response functions to gamma-ray point sources for a spherical NaI(Tl) detector
    Yi, Chul-Young
    Hah, Suck-Ho
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2133 - 2136
  • [33] Determination of self-attenuation correction factors for 3"x 3"NaI(Tl) detector by using Monte Carlo Code FLUKA
    Cetinkaya, Hakan
    RADIATION PHYSICS AND CHEMISTRY, 2025, 230
  • [34] Experimentally validated Monte Carlo simulation of an XtRa-NaI(Tl) Compton Suppression System response
    Savva, Marilia
    Anagnostakis, Marios
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 555 - 557
  • [35] MONTE-CARLO CALCULATION OF THE RESPONSE OF NAI(TL) SCINTILLATION SPECTROMETERS
    BERGER, MJ
    DOGGETT, JA
    PHYSICAL REVIEW, 1955, 99 (02): : 663 - 663
  • [36] Simulation of a NaI(Tl) detector model using OpenMC modified on code source and validation using experimental and simulated results
    El-Bouzaidi, Mohamed Drissi
    El Bardouni, T.
    El Hajjaji, Otman
    Idrissi, Abdelghani
    Chham, Essaid
    Milena Perez, Abel
    Mira, Mohamed
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [37] A simple model for the growth of polycrystalline Si using the kinetic Monte Carlo simulation
    Levine, SW
    Clancy, P
    MODELLING AND SIMULATION IN MATERIALS SCIENCE AND ENGINEERING, 2000, 8 (05) : 751 - 762
  • [38] MONTE-CARLO CALCULATION OF NAI(TL) DETECTOR RESPONSE FUNCTIONS FOR LOW-ENERGY GAMMA-RAYS
    SAITO, K
    MORIUCHI, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 226 (2-3): : 449 - 454
  • [39] An inversion decomposition test based on Monte Carlo response matrix on the γ-ray spectra from NaI(Tl) scintillation detector
    He, Jian-Feng
    Wu, Qi-Fan
    Cheng, Jian-Ping
    Fang, Fang
    Yang, Yao-Zong
    Qu, Jin-Hui
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (04)
  • [40] An inversion decomposition test based on Monte Carlo response matrix on the γ-ray spectra from NaI(Tl) scintillation detector
    Jian-Feng He
    Qi-Fan Wu
    Jian-Ping Cheng
    Fang Fang
    Yao-Zong Yang
    Jin-Hui Qu
    Nuclear Science and Techniques, 2016, 27