Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation

被引:0
|
作者
ChunHui Gong
GuoQiang Zeng
LiangQuan Ge
Xiaobin Tang
ChengJun Tan
机构
[1] Nanjing University of Aeronautics and Astronautics,Department of Nuclear Science and Engineering
[2] Chengdu University of Technology,College of Nuclear Technology and Automation Engineering
来源
关键词
NaI(Tl) airborne ; ray spectrometry; minimum detectable activity; Monte Carlo simulation;
D O I
暂无
中图分类号
学科分类号
摘要
The determination of the effective minimum detectable activity (MDA) of radionuclides by a detection system plays an important role in environmental radiation monitoring. In this study, the responses of an NaI(Tl) airborne γ ray spectrometry (AGRS) system to different radionuclides (137Cs and 131I) were investigated using the Monte Carlo technique. The MDA values were determined under different conditions according to the counting spectra obtained from the Monte Carlo simulation. The equivalent mass thickness method was applied to the Monte Carlo modeling for monitoring ground radiation to reduce statistical uncertainty. The secondary source method was used to monitor both air and ground radiation. A quadratic relationship was found between the MDA and activity concentration. An exponential relationship was found between the MDA and altitude. The MDA of a specific radionuclide from external detectors was found to be superior to that obtained from internal detectors under the same conditions. The MDA values in an NaI(Tl) AGRS system under different conditions can be estimated based on the results of this study.
引用
收藏
页码:1840 / 1845
页数:5
相关论文
共 50 条
  • [1] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    GONG ChunHui
    ZENG GuoQiang
    GE LiangQuan
    TANG Xiaobin
    TAN ChengJun
    Science China(Technological Sciences), 2014, (09) : 1840 - 1845
  • [2] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    GONG ChunHui
    ZENG GuoQiang
    GE LiangQuan
    TANG Xiaobin
    TAN ChengJun
    Science China(Technological Sciences), 2014, 57 (09) : 1840 - 1845
  • [3] Minimum detectable activity for NaI(Tl) airborne γ-ray spectrometry based on Monte Carlo simulation
    Gong ChunHui
    Zeng GuoQiang
    Ge LiangQuan
    Tang Xiaobin
    Tan ChengJun
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (09) : 1840 - 1845
  • [4] Monte Carlo simulation of a NaI(Tl) detector efficiency
    Akkurt, Iskender
    Waheed, Faez
    Akyildirim, Hakan
    Gunoglu, Kadir
    RADIATION PHYSICS AND CHEMISTRY, 2020, 176
  • [5] Precise Monte Carlo simulation of gamma-ray response functions for an NaI(Tl) detector
    Shi, HX
    Chen, BX
    Li, TZ
    Yun, D
    APPLIED RADIATION AND ISOTOPES, 2002, 57 (04) : 517 - 524
  • [6] Minimum detectable activity in in situ γ-ray spectrometry
    Nir-El, Y
    Haquin, G
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (02) : 197 - 203
  • [7] MONTE CARLO SIMULATION APPLIED TO HEXAGONAL NaI(Tl) DETECTORS.
    Jerrestam, Dan
    Nuclear instruments and methods in physics research, 1986, 244 (03): : 542 - 546
  • [8] Monte Carlo simulation of a NaI[Tl] detector's response function
    Olaniyi, H. B.
    Owojori, A. A.
    Olise, F. S.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [9] Investigating the minimum detectable activity concentration and contributing factors in airborne gamma-ray spectrometry
    Yi Gu
    Kun Sun
    Liang-Quan Ge
    Yuan-Dong Li
    Qing-Xian Zhang
    Xuan Guan
    Wan-Chang Lai
    Zhong-Xiang Lin
    Xiao-Zhong Han
    NuclearScienceandTechniques, 2021, 32 (10) : 86 - 94
  • [10] Investigating the minimum detectable activity concentration and contributing factors in airborne gamma-ray spectrometry
    Yi Gu
    Kun Sun
    Liang-Quan Ge
    Yuan-Dong Li
    Qing-Xian Zhang
    Xuan Guan
    Wan-Chang Lai
    Zhong-Xiang Lin
    Xiao-Zhong Han
    Nuclear Science and Techniques, 2021, 32