Total body irradiation using helical tomotherapy: Set-up experience and in-vivo dosimetric evaluation

被引:9
|
作者
Cleuziou, J. P. [1 ]
Desgranges, C. [1 ]
Henry, I [1 ]
Jaumot, M. [1 ]
Chartier, P. [1 ]
Sihanath, R. [1 ]
Carre, M. [2 ]
Bulabois, C. E. [2 ]
Cahn, J. Y. [2 ]
Pasteris, C. [1 ]
Balosso, J. [1 ]
Gabelle-Flandin, I [1 ]
Verry, C. [1 ]
Giraud, J. Y. [1 ]
机构
[1] Ctr Hosp Univ Grenoble Alpes CHUGA, Serv Radiotherapie, CS 10217, Grenoble 9, France
[2] Ctr Hosp Univ Grenoble Alpes CHUGA, Serv Hematol, CS 10217, Grenoble 9, France
来源
CANCER RADIOTHERAPIE | 2021年 / 25卷 / 03期
关键词
Helical tomotherapy; Total body irradiation; FEASIBILITY; TBI;
D O I
10.1016/j.canrad.2020.07.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - Helical Tomotherapy (HT) appears as a valuable technique for total body irradiation (TBI) to create highly homogeneous and conformal dose distributions with more precise repositioning than conventional TBI techniques. The aim of this work is to describe the technique implementation, including treatment preparation, planning and dosimetric monitoring of TBI delivered in our institution from October 2016 to March 2019. Material and method. - Prior to patient care, irradiation protocol was set up using physical phantoms. Gafchromic films were used to assess dose distribution homogeneity and evaluate imprecise patient positioning impact. Sixteen patients' irradiations with a prescribed dose of 12 Gy were delivered in 6 fractions of 2 Gy over 3 days. Pre-treatment quality assurance (QA) was performed for the verification of dose distributions at selected positions. In addition, in-vivo dosimetry was carried out using optically stimulated luminescence dosimeters (OSLD). Results. - Planning evaluation, as well as results of pre-treatment verifications, are presented. In-vivo dosimetry showed the strong consistency of OSLD measured doses. OSLD mean relative dose differences between measurement and calculation were respectively +0,96% and -2% for armpit and hands locations, suggesting better reliability for armpit OSLD positioning. Repercussion of both longitudinal and transversal positioning inaccuracies on phantoms is depicted up to 2 cm shifts. Conclusion. - The full methodology to set up TBI protocol, as well as dosimetric evaluation and pretreatment QA, were presented. Our investigations reveal strong correspondence between planned and delivered doses shedding light on the dose reliability of OSLD for HT based TBI in-vivo dosimetry. (C) 2020 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [41] Fractionated Total Body Irradiation on an Infant Using Tomotherapy
    Abraham, Usha
    Romaguera, Tino
    Tolakanahalli, Ranjini
    Gutierrez, Alonso N.
    Hall, Matthew
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
  • [42] Deformable Model Based Dose Reconstruction for Total Body Irradiation with Helical TomoTherapy
    Chao, M.
    Penagaricano, J.
    Yan, Y.
    Moros, E.
    Gardner, K.
    Corry, P.
    Ratanatharathorn, V.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [43] VOXEL-BASED DOSE RECONSTRUCTION FOR TOTAL BODY IRRADIATION WITH HELICAL TOMOTHERAPY
    Chao, Ming
    Penagaricano, Jose
    Yan, Yulong
    Moros, Eduardo G.
    Corry, Peter
    Ratanatharathorn, Vaneerat
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1575 - 1583
  • [44] Lung sparing and ribcage coverage in total body irradiation delivered by helical tomotherapy
    Koeksal, Muemtaz
    Baumert, Jonathan
    Schoroth, Felix
    Scafa, Davide
    Koch, David
    Leitzen, Christina
    Sarria, Gustavo R.
    Giordano, Frank A.
    Chatzikonstantinou, Georgios
    Schmeel, Leonard C.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2022, 27 (01)
  • [45] Dose Verification and Plan Adaptation in Megavoltage CT Guided Total Body Irradiation using Helical Tomotherapy
    Chao, M.
    Penagaricano, J.
    Moros, E.
    Corry, P.
    Ratanatharathorn, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S632 - S632
  • [46] Appropriate treatment planning method for field joint dose in total body irradiation using helical tomotherapy
    Usui, Keisuke
    Isobe, Akira
    Hara, Naoya
    Shikama, Naoto
    Sasai, Keisuke
    Ogawa, Koichi
    MEDICAL DOSIMETRY, 2019, 44 (04) : 344 - 353
  • [47] Planning Study for the Reduction of Radiation Exposure of the Lungs during Total Body Irradiation using helical Tomotherapy
    Muedder, T.
    Schmeel, L. C.
    Leitzen, C.
    Oberste-Beulmann, S.
    Garbe, S.
    Schueller, H.
    Roehner, F.
    Schoroth, F.
    Simon, B.
    Wilhelm-Buchstab, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 85 - 86
  • [48] Ultrafast Deformable Image Registration for Potential Adaptive Total Body Irradiation Therapy Using Helical TomoTherapy
    Chao, M.
    Penagaricano, J.
    Moros, E.
    MEDICAL PHYSICS, 2010, 37 (06) : 3125 - +
  • [49] Quality Assurance for Total Marrow Irradiation (TMI) Using Helical Tomotherapy
    Zhang, X.
    Penagaricano, J.
    Yan, Y.
    Hancock, S.
    Ratanatharathorn, V.
    Corry, P.
    Moros, E.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [50] A Multicentric study on a dosimetric comparison of extended SSD technique, VMAT-Based and helical tomotherapy (HT) for total body irradiation (TBI}
    Dinc, Serap Catli
    Kucuk, Nadir
    Senkesenc, Oznur
    Ayata, Hande Bas
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (03)