Helical tomotherapy;
Total body irradiation;
FEASIBILITY;
TBI;
D O I:
10.1016/j.canrad.2020.07.009
中图分类号:
R73 [肿瘤学];
学科分类号:
100214 ;
摘要:
Purpose. - Helical Tomotherapy (HT) appears as a valuable technique for total body irradiation (TBI) to create highly homogeneous and conformal dose distributions with more precise repositioning than conventional TBI techniques. The aim of this work is to describe the technique implementation, including treatment preparation, planning and dosimetric monitoring of TBI delivered in our institution from October 2016 to March 2019. Material and method. - Prior to patient care, irradiation protocol was set up using physical phantoms. Gafchromic films were used to assess dose distribution homogeneity and evaluate imprecise patient positioning impact. Sixteen patients' irradiations with a prescribed dose of 12 Gy were delivered in 6 fractions of 2 Gy over 3 days. Pre-treatment quality assurance (QA) was performed for the verification of dose distributions at selected positions. In addition, in-vivo dosimetry was carried out using optically stimulated luminescence dosimeters (OSLD). Results. - Planning evaluation, as well as results of pre-treatment verifications, are presented. In-vivo dosimetry showed the strong consistency of OSLD measured doses. OSLD mean relative dose differences between measurement and calculation were respectively +0,96% and -2% for armpit and hands locations, suggesting better reliability for armpit OSLD positioning. Repercussion of both longitudinal and transversal positioning inaccuracies on phantoms is depicted up to 2 cm shifts. Conclusion. - The full methodology to set up TBI protocol, as well as dosimetric evaluation and pretreatment QA, were presented. Our investigations reveal strong correspondence between planned and delivered doses shedding light on the dose reliability of OSLD for HT based TBI in-vivo dosimetry. (C) 2020 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
机构:
Inst Univ Canc Toulouse, Dept Med Phys, F-31059 Toulouse 9, FranceInst Univ Canc Toulouse, Dept Med Phys, F-31059 Toulouse 9, France
Ferrand, Regis
Bardies, Manuel
论文数: 0引用数: 0
h-index: 0
机构:
Fac Med Toulouse, INSERM, UMR 1037, Team 15, F-31073 Toulouse, FranceInst Univ Canc Toulouse, Dept Med Phys, F-31059 Toulouse 9, France
Bardies, Manuel
Ken, Soleakhena
论文数: 0引用数: 0
h-index: 0
机构:
Inst Univ Canc Toulouse, Dept Med Phys, F-31059 Toulouse 9, FranceInst Univ Canc Toulouse, Dept Med Phys, F-31059 Toulouse 9, France
Ken, Soleakhena
Simon, Luc
论文数: 0引用数: 0
h-index: 0
机构:
Inst Univ Canc Toulouse, Dept Med Phys, F-31059 Toulouse 9, France
Fac Med Toulouse, INSERM, UMR 1037, Team 15, F-31073 Toulouse, FranceInst Univ Canc Toulouse, Dept Med Phys, F-31059 Toulouse 9, France
Simon, Luc
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS,
2015,
16
(06):
: 164
-
176