Total body irradiation using helical tomotherapy: Set-up experience and in-vivo dosimetric evaluation

被引:9
|
作者
Cleuziou, J. P. [1 ]
Desgranges, C. [1 ]
Henry, I [1 ]
Jaumot, M. [1 ]
Chartier, P. [1 ]
Sihanath, R. [1 ]
Carre, M. [2 ]
Bulabois, C. E. [2 ]
Cahn, J. Y. [2 ]
Pasteris, C. [1 ]
Balosso, J. [1 ]
Gabelle-Flandin, I [1 ]
Verry, C. [1 ]
Giraud, J. Y. [1 ]
机构
[1] Ctr Hosp Univ Grenoble Alpes CHUGA, Serv Radiotherapie, CS 10217, Grenoble 9, France
[2] Ctr Hosp Univ Grenoble Alpes CHUGA, Serv Hematol, CS 10217, Grenoble 9, France
来源
CANCER RADIOTHERAPIE | 2021年 / 25卷 / 03期
关键词
Helical tomotherapy; Total body irradiation; FEASIBILITY; TBI;
D O I
10.1016/j.canrad.2020.07.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - Helical Tomotherapy (HT) appears as a valuable technique for total body irradiation (TBI) to create highly homogeneous and conformal dose distributions with more precise repositioning than conventional TBI techniques. The aim of this work is to describe the technique implementation, including treatment preparation, planning and dosimetric monitoring of TBI delivered in our institution from October 2016 to March 2019. Material and method. - Prior to patient care, irradiation protocol was set up using physical phantoms. Gafchromic films were used to assess dose distribution homogeneity and evaluate imprecise patient positioning impact. Sixteen patients' irradiations with a prescribed dose of 12 Gy were delivered in 6 fractions of 2 Gy over 3 days. Pre-treatment quality assurance (QA) was performed for the verification of dose distributions at selected positions. In addition, in-vivo dosimetry was carried out using optically stimulated luminescence dosimeters (OSLD). Results. - Planning evaluation, as well as results of pre-treatment verifications, are presented. In-vivo dosimetry showed the strong consistency of OSLD measured doses. OSLD mean relative dose differences between measurement and calculation were respectively +0,96% and -2% for armpit and hands locations, suggesting better reliability for armpit OSLD positioning. Repercussion of both longitudinal and transversal positioning inaccuracies on phantoms is depicted up to 2 cm shifts. Conclusion. - The full methodology to set up TBI protocol, as well as dosimetric evaluation and pretreatment QA, were presented. Our investigations reveal strong correspondence between planned and delivered doses shedding light on the dose reliability of OSLD for HT based TBI in-vivo dosimetry. (C) 2020 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [31] Total skin irradiation using helical tomotherapy: a novel experience and report of three cases
    Okuma, K.
    Haga, A.
    Imae, T.
    Takenaka, R.
    Sugaya, M.
    Nakagawa, K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S649 - S649
  • [32] Dosimetric study and in-vivo dose verification for conformal avoidance helical tomotherapy of anal adenocarcinoma
    Han, C.
    Chen, Y.
    Liu, A.
    Schultheiss, T.
    Wong, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2093 - 2093
  • [33] CRANIOSPINAL IRRADIATION USING HELICAL TOMOTHERAPY: THE MCGILL EXPERIENCE
    Bahig, Houda
    Panet-Raymond, Valerie
    Freeman, Carolyn
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S76 - S77
  • [34] Allogeneic Stem Cell Transplantation after total-body Irradiation using Helical Tomotherapy - A Single Center Experience
    Heinicke, Thomas
    Waldleben, Ana-Maria
    Wolleschak, Denise
    Brunner, Thomas
    Gademann, Guenther
    Fischer, Thomas
    Ochel, Hans-Joachim
    BONE MARROW TRANSPLANTATION, 2020, 55 (SUPPL 1) : 303 - 304
  • [35] Evaluation of Total Body Irradiation Technique Using 20 Diodes In-Vivo Dosimetry System
    Zhou, P.
    Kiszka, D.
    Zhang, H.
    Jia, Y.
    Desrosiers, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [36] DOSE RATE ISSUES IN TOTAL BODY IRRADIATION DELIVERED WITH HELICAL TOMOTHERAPY
    Mazal, A.
    Caneva, S.
    Lesven, C.
    Francois, P.
    Zefkili, S.
    Kirova, Y.
    Helfre, S.
    Fourquet, A.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S493 - S493
  • [37] Unique radiation dermatitis related to total body irradiation by helical tomotherapy
    Takenaka, Ryosuke
    Yamashita, Hideomi
    Toya, Takashi
    Haga, Akihiro
    Shibata, Shino
    Kurokawa, Mineo
    Ootomo, Kuni
    Nakagawa, Keiichi
    JOURNAL OF DERMATOLOGY, 2016, 43 (11): : 1376 - 1377
  • [38] A novel approach to total skin irradiation using helical TomoTherapy
    Sarfehnia, Arman
    Poon, Emily
    Davis, Stephen D.
    Fleming, Adam
    Mitchell, David
    Freeman, Carolyn R.
    PRACTICAL RADIATION ONCOLOGY, 2014, 4 (05) : 330 - 335
  • [39] Evaluation of a dose delivery verification system for in-vivo dosimetry in helical Tomotherapy
    Lesven, C.
    Losa, S.
    Francois, P.
    Mazal, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (10) : 690 - 690
  • [40] Lung sparing and ribcage coverage in total body irradiation delivered by helical tomotherapy
    Mümtaz Köksal
    Jonathan Baumert
    Felix Schoroth
    Davide Scafa
    David Koch
    Christina Leitzen
    Gustavo R. Sarria
    Frank A. Giordano
    Georgios Chatzikonstantinou
    Leonard C. Schmeel
    European Journal of Medical Research, 27