Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences

被引:4
|
作者
Inoue, Katsuhiro [1 ]
Maeda, Masayuki [2 ]
Umino, Maki [3 ]
Takase, Shinichi [1 ]
Yamahata, Tsunehiro [1 ]
Sakuma, Hajime [3 ]
机构
[1] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[2] Mie Univ, Sch Med, Dept Adv Diagnost Imaging, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Mie Univ, Sch Med, Depatment Radiol, Tsu, Mie 5148507, Japan
基金
日本学术振兴会;
关键词
Carotid plaque; Magnetic resonance imaging; Black blood; 3D imaging; INTRAPLAQUE HEMORRHAGE; RISK; PROGRESSION; DISEASE; MRI;
D O I
10.1016/j.ejrad.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field -echo (TFE) black blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36-83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1 -TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1 -TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1-TFEBB MRI than on 3D T1 -TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1 -TSEBB MRI. Conclusions: 3D Tl-TSEBB MRI was superior to 3D Tl-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1 -TSEBB MRI. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1035 / 1039
页数:5
相关论文
共 50 条
  • [41] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Andrew B. Wolff
    Lorenzo L. Pesce
    Jim S. Wu
    L. Ryan Smart
    Michael J. Medvecky
    Andrew H. Haims
    Skeletal Radiology, 2009, 38 : 21 - 29
  • [42] Comparison between turbo spin-echo and echo planar diffusion-weighted imaging of the female pelvis with 3T MRI
    Yoshizako, Takeshi
    Yoshida, Rika
    Asou, Hiroya
    Nakamura, Megumi
    Kitagaki, Hajime
    ACTA RADIOLOGICA OPEN, 2021, 10 (02)
  • [43] Visualization and Evaluation of Human Lenticulostriate Arteries Using High-resolution Black-blood T1-weighted Turbo-spin Echo (TSE) at 3T and 7T
    Ma, Samantha J.
    Yan, Lirong
    Wang, Danny J.
    STROKE, 2018, 49
  • [44] Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    van Smoorenburg, Luuk
    Schwenk, Arpad
    Mannil, Manoj
    Graf, Nicole
    Binkert, Christoph A.
    Wyss, Michael
    Sartoretti-Schefer, Sabine
    INVESTIGATIVE RADIOLOGY, 2020, 55 (12) : 775 - 784
  • [45] 3D T1-weighted black-blood magnetic resonance imaging for the diagnosis of giant cell arteritis
    Rodriguez-Regent, C.
    Hassen, W. Ben
    Seners, P.
    Oppenheim, C.
    Regent, A.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2020, 38 (02) : S95 - S98
  • [46] Knee Derangements: Comparison of Isotropic 3D Fast Spin-Echo, Isotropic 3D Balanced Fast Field-Echo, and Conventional 2D Fast Spin-Echo MR Imaging
    Jung, Jin Young
    Yoon, Young Cheol
    Kim, Hye Rin
    Choe, Bong-Keun
    Wang, Joon Ho
    Jung, Jee Young
    RADIOLOGY, 2013, 268 (03) : 802 - 813
  • [47] 3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study with 3D isotropic fast-field echo sequence
    Seo, Jung Min
    Yoon, Young Cheol
    Kwon, Jong Won
    ACTA RADIOLOGICA, 2011, 52 (10) : 1119 - 1124
  • [48] Magnetic Resonance Imaging of the Sacroiliac Joints in Patients with Suspected Spondyloarthritis - Comparison of Turbo Spin-Echo and Gradient-Echo Sequences for the Detection of Structural Alterations
    Dornia, C.
    Fleck, M.
    Hartung, W.
    Niessen, C.
    Stroszczynski, C.
    Hoffstetter, P.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (02): : 109 - 114
  • [49] Cardiovascular magnetic resonance assessment of human myocarditis: IR gradient echo compared with T1 turbo spin-echo imaging protocols
    Hager, S
    Mahrholdt, H
    Mangin, M
    Wagner, A
    Sechtem, U
    CIRCULATION, 2004, 110 (17) : 678 - 678
  • [50] Intravascular enhancement sign at 3D T1-weighted turbo spin echo sequence is associated with cerebral atherosclerotic stenosis
    Wang, Bo
    Feng, Ouyang
    Wu, Qin
    Chen, Jingting
    Liu, Jie
    Xu, Zihe
    Lv, Lianjiang
    Yu, Nianzu
    Zeng, Xianjun
    MAGNETIC RESONANCE IMAGING, 2025, 115